Key Specifications
:Machine building
Fuse:G / 5 x 20
Color:blue
Depth:63.4 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Machine building
FuseG / 5 x 20
Colorblue
Depth63.4 mm
Width6.2 mm
Height56 mm
GeneralThe current is determined by the fuse used, the voltage by the selected LED.If the fuse is faulty, the downstream circuit will not be disconnected.
Fuse typeGlass / ceramics / ...
Potentials1
Product typeFuse terminal block
Mounting typeNS 35/7,5
Number of rows1
End cover width2.2 mm
Nominal current6.3 A
Nominal voltage24 V
Open side panelYes
Stripping length10 mm ... 12 mm
Cross section AWG(converted acc. to IEC)
LED current range0.31 mA ... 0.95 mA
LED voltage range12 V AC/DC ... 30 V AC/DC
Depth on NS 35/1570 mm
Area of applicationRailway industry
Degree of pollution3
Depth on NS 35/7,562.5 mm
Insulating materialPA
Rated surge voltage4 kV
Maximum load current6.3 A (with 6 mm² conductor cross section, rigid)
Overvoltage categoryIII
Nominal cross section4 mm²
Number of connections2
Insulating material groupI
Internal cylindrical gageA4
Maximum power dissipationmax. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
Conductor cross section rigid0.2 mm² ... 6 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.2 mm² ... 6 mm²
Connection in acc. with standardIEC 60947-7-3
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]24 ... 10 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition1.02 W
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 4 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1 mm²

Product Description

Fuse rail terminal, fuse type: Glass/ceramic/..., connection type: Push-in connection, section: 0.2 mm²- 6 mm², AWG: 24 - 10, rated current: 6.3 A, rated voltage: 24 V, width: 6.2 mm, fuse type: G/5 x
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top