| Parameter | Value |
|---|---|
| B3 | |
| Color | gray |
| Width | 5.2 mm |
| Height | 142.4 mm |
| Result | Test passed |
| Spectrum | Service life test category 2, bogie-mounted |
| ASD level | 6.12 (m/s²)²/Hz |
| Frequency | f1= 5 Hz to f2= 250 Hz |
| Pulse shape | Half-sine |
| Acceleration | 3.12g |
| Product type | Ground terminal block |
| Mounting type | NS 35/7,5 |
| Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Shock duration | 18 ms |
| End cover width | 2.2 mm |
| Nominal current | 18 A |
| Nominal voltage | 500 V |
| Open side panel | Yes |
| Test directions | X-, Y- and Z-axis |
| Stripping length | 8 mm ... 10 mm |
| Cross section AWG | (converted acc. to IEC) |
| Depth on NS 35/15 | 76.1 mm |
| Degree of pollution | 3 |
| Depth on NS 35/7,5 | 68.6 mm |
| Insulating material | PA |
| Number of positions | 4 |
| Rated surge voltage | 6 kV |
| Maximum load current | 20 A (with 4 mm² conductor cross-section) |
| Overvoltage category | III |
| Nominal cross section | 2.5 mm² |
| Number of connections | 8 |
| Test duration per axis | 5 h |
| Insulating material group | I |
| Internal cylindrical gage | A3 |
| Conductor cross section rigid | 0.14 mm² ... 4 mm² |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Number of shocks per direction | 3 |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Ambient temperature (operation) | -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.) |
| Number of connections per level | 2 |
| Conductor cross section flexible | 0.14 mm² ... 4 mm² |
| Connection in acc. with standard | IEC 60947-7-2 |
| Conductor cross section, rigid [AWG] | 20 ... 12 (converted acc. to IEC) |
| Flammability rating according to UL 94 | V0 |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Conductor cross section, flexible [AWG] | 26 ... 12 (converted acc. to IEC) |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Static insulating material application in cold | -60 °C |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² |