Service time: Monday to Friday 9:00-18:00
PT 2,5-PE/L/N/TG - PT 2,5-PE/L/N/TG 1336374 PHOENIX CONTACT Ground terminal, number of connections: 8, number of poles: 4, conn..
In Stock Hot Product

PT 2,5-PE/L/N/TG

PT 2,5-PE/L/N/TG 1336374 PHOENIX CONTACT Ground terminal, number of connections: 8, number of poles: 4, conn..

$9.42USD
1103 in stock
Key Specifications
:B3
Color:gray
Width:5.2 mm
Height:142.4 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
B3
Colorgray
Width5.2 mm
Height142.4 mm
ResultTest passed
SpectrumService life test category 2, bogie-mounted
ASD level6.12 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 250 Hz
Pulse shapeHalf-sine
Acceleration3.12g
Product typeGround terminal block
Mounting typeNS 35/7,5
SpecificationDIN EN 50155 (VDE 0115-200):2022-06
Shock duration18 ms
End cover width2.2 mm
Nominal current18 A
Nominal voltage500 V
Open side panelYes
Test directionsX-, Y- and Z-axis
Stripping length8 mm ... 10 mm
Cross section AWG(converted acc. to IEC)
Depth on NS 35/1576.1 mm
Degree of pollution3
Depth on NS 35/7,568.6 mm
Insulating materialPA
Number of positions4
Rated surge voltage6 kV
Maximum load current20 A (with 4 mm² conductor cross-section)
Overvoltage categoryIII
Nominal cross section2.5 mm²
Number of connections8
Test duration per axis5 h
Insulating material groupI
Internal cylindrical gageA3
Conductor cross section rigid0.14 mm² ... 4 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.14 mm² ... 4 mm²
Connection in acc. with standardIEC 60947-7-2
Conductor cross section, rigid [AWG]20 ... 12 (converted acc. to IEC)
Flammability rating according to UL 94V0
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]26 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Static insulating material application in cold-60 °C
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²

Product Description

Protective conductor terminal, number of connections: 8, number of positions: 4, connection method: Push-in connection, Protective conductor connection, Rated cross section: 2.5 mm2, cross section: 0.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top