Service time: Monday to Friday 9:00-18:00
PT 2,5-L/L/L/TG - PT 2,5-L/L/L/TG 1336395 PHOENIX CONTACT Multi-Floor Terminal Block
In Stock Hot Product

PT 2,5-L/L/L/TG

PT 2,5-L/L/L/TG 1336395 PHOENIX CONTACT Multi-Floor Terminal Block

$7.40USD
1388 in stock
Key Specifications
:B3
Note:The max. load current must not be exceeded by the total current of all connected conductors.
Color:gray
Width:5.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
B3
NoteThe max. load current must not be exceeded by the total current of all connected conductors.
Colorgray
Width5.2 mm
Height142.4 mm
ResultTest passed
SpectrumService life test category 1, class B, body mounted
ASD level0.964 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 150 Hz
Pulse shapeHalf-sine
Revolutions135
Acceleration0.964g
Product typeDisconnect terminal block
Mounting typeNS 35/7,5
SpecificationDIN EN 50155 (VDE 0115-200):2022-06
Number of rows4
Rotation speed10 (+/- 2) rpm
Shock duration30 ms
End cover width2.2 mm
Nominal voltage500 V
Open side panelYes
Test directionsX-, Y- and Z-axis
Stripping length8 mm ... 10 mm
Time of exposure30 s
Cross section AWG(converted acc. to IEC)
Depth on NS 35/1576.1 mm
Temperature cycles192
Degree of pollution3
Depth on NS 35/7,568.6 mm
Insulating materialPA
Number of positions4
Rated surge voltage6 kV
Maximum load current20 A (with 4 mm² conductor cross-section)
Overvoltage categoryIII
Nominal cross section2.5 mm²
Number of connections8
Test voltage setpoint6 kV
Test duration per axis5 h
DIN rail/fixing supportNS 32/NS 35
Insulating material groupI
Internal cylindrical gageA3
Conductor cross section rigid0.14 mm² ... 4 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Conductor cross section/weight0.14 mm² / 0.2 kg
Number of shocks per direction3
Thermal continuous current Ith18 A (with a 2.5 mm² conductor cross section)
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.14 mm² ... 4 mm²
Connection in acc. with standardIEC 60947-7-1
Requirement temperature-rise testIncrease in temperature ≤ 45 K
Conductor cross section, rigid [AWG]20 ... 12 (converted acc. to IEC)
Short-time withstand current 2.5 mm²0.3 kA
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]26 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Static insulating material application in cold-60 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²

Product Description

Disconnect terminal block, nom. voltage: 500 V, Thermal continuous current Ith: 18 A, connection method: Push-in connection, Rated cross section: 2.5 mm2, cross section: 0.14 mm2 - 4 mm2, mounting: NS
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual