Service time: Monday to Friday 9:00-18:00
PT 2,5-4PE - PT 2,5-4PE 1336413 PHOENIX CONTACT Ground terminal, number of connections: 8, number of poles: 4, connection..
In Stock Hot Product

PT 2,5-4PE

PT 2,5-4PE 1336413 PHOENIX CONTACT Ground terminal, number of connections: 8, number of poles: 4, connection..

$8.90USD
1157 in stock
Key Specifications
:Machine building
Note:When establishing a connection on the open housing side of a feed-through modular terminal block of the same series and size, the block must be provided with a cover if the expected insulation voltage is >690 V.
Color:gray
Width:5.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Machine building
NoteWhen establishing a connection on the open housing side of a feed-through modular terminal block of the same series and size, the block must be provided with a cover if the expected insulation voltage is >690 V.
Colorgray
Width5.2 mm
Height142.4 mm
ResultTest passed
SpectrumService life test category 1, class B, body mounted
ASD level0.964 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 150 Hz
Pulse shapeHalf-sine
Acceleration0.58g
Product typeGround terminal block
Mounting typeNS 35/7,5
SpecificationDIN EN 50155 (VDE 0115-200):2022-06
Number of rows4
Shock duration30 ms
End cover width2.2 mm
Open side panelYes
Test directionsX-, Y- and Z-axis
Stripping length8 mm ... 10 mm
Cross section AWG(converted acc. to IEC)
Depth on NS 35/1576.1 mm
Area of applicationRailway industry
Degree of pollution3
Depth on NS 35/7,568.6 mm
Insulating materialPA
Number of positions4
Rated surge voltage6 kV
Overvoltage categoryIII
Nominal cross section2.5 mm²
Number of connections8
Test duration per axis5 h
Insulating material groupI
Internal cylindrical gageA3
Conductor cross section rigid0.14 mm² ... 4 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.14 mm² ... 4 mm²
Connection in acc. with standardIEC 60947-7-2
Conductor cross section, rigid [AWG]20 ... 12 (converted acc. to IEC)
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]26 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition0.77 W
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²

Product Description

Ground terminal, number of connections: 8, number of positions: 4, connection method: Push-in connection, Rated cross section: 2.5 mm2, cross section: 0.14 mm2 - 4 mm2, mounting type: NS 35/7,5, NS 35
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top