| Parameter | Value |
|---|---|
| Machine building | |
| Exit | (permanent) |
| Color | multicoloured |
| Depth | 49.5 mm |
| Scope | Railway industry |
| Turns | 135 |
| width | 10.2 mm |
| Result | Test passed |
| height | 67.7 mm |
| Marking | II 2 GD Ex eb IIC Gb |
| Spectrum | Electrical Life Check Category 1, Class B, Body Mounted |
| ASD Level | 1,857 (m/s²)²/Hz |
| Frequency | f1= 5 Hz a f2= 150 Hz |
| Gauge Pad | A6 |
| Potential | 1 |
| Shock Form | Semi-sinusoidal |
| Jumper list | Plug-in jumper / FBS 2-10 / 3005947 |
| Acceleration | 0.8g |
| Bridges data | 48 A / 10 mm² |
| Product Type | Feed-through clamp |
| Mounting type | NS 35/7.5 |
| Rated current | 57 A |
| Article review | 03 |
| Number of rows | 1 |
| Open side wall | Yes |
| Shock Duration | 30 ms |
| Nominal voltage | 1000 V |
| Test Directions | X, Y, and Z axis |
| Mass Resistivity | 0.43 mΩ |
| Rotational speed | 10 rpm |
| Depth on NS 35/15 | 58 mm |
| AWG Sizing Section | 8 |
| Depth on NS 35/7.5 | 50.5 mm |
| Manoeuvring cycles | 100 |
| Test Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| AWG Connection Data | 20 ... 6 |
| Degree of pollution | 3 |
| Insulation material | PA |
| Temperature Cycling | 192 |
| Temperature rise Ex | 40 K (52.5 A / 10 mm²) |
| Maximum load current | 70 A (with a conductor cross-section of 16 mm²) |
| Overvoltage Category | Iii |
| Nominal cross-section | 10 mm² |
| Number of connections | 2 |
| Sizing Impulse Voltage | 8 kV |
| Test duration per axle | 5 h |
| Test force rated value | 5 N |
| Duration of application | 30 s |
| Ex Certified Accessories | 3212057 D-PT 10 |
| Rated insulation voltage | 500 V |
| Test voltage rated value | 9.8 kV |
| Insulation Material Group | The |
| Thickness of the end plate | 2.2 mm |
| Conductor cross-section AWG | 20 ... 6 (converted according to IEC) |
| Support rail/fixing support | NS 35 |
| Rigid conductor cross-section | 0.5 mm² ... 16 mm² |
| Standard-compliant connection | IEC 60947-7-1 |
| Ambient temperature (mounting) | -5 °C ... 70 °C |
| Conductor cross-section/weight | 0.5 mm2/0.3 kg |
| In case of bridges with jumper | 550 V |
| Number of connections per plan | 2 |
| Number of shocks per direction | 3 |
| Ambient temperature (operating) | -60 °C ... 110 °C (Operating temperature range including self-heating, short-term maximum operating temperature cf. RTI Elec.) |
| Operating temperature range (1) | -60 °C ... 85 °C |
| Operating temperature range (2) | -40 °C ... 110 °C |
| Ambient Temperature (Activation) | -5 °C ... 70 °C |
| Connection data solid conductors | 0.5 mm² ... 16 mm² |
| Flexible conductor cross-section | 0.5 mm² ... 16 mm² |
| Heating verification requirement | Temperature rise ≤ 45 K |
| Permissible humidity (operation) | 20 % ... 90 % |
| NFPA 130 Fume Toxicity (SMP 800C) | Exceeded |
| Flexible conductor connection data | 0.5 mm² ... 10 mm² |
| Length of the section to be stripped | 18 mm ... 20 mm |
| Short-term current resistance 10 mm² | 1.2 kA |
| Short-term current resistance 16 mm² | 1.92 kA |
| Cold static insulation material insert | -60 °C |
| Flexible conductor cross-section [AWG] | 20 ... 6 (converted according to IEC) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for short duration, no longer than 24 h, -60 °C to +70 °C) |
| Combustibility class according to UL 94 | V0 |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Surface Flammability NFPA 130 (ASTM E 162) | Exceeded |
| Maximum power dissipation under nominal conditions | 1.82 W |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| NFPA 130 (ASTM E 662) Specific Optical Density of Fumes | Exceeded |
| Flexible conductor cross-section (plastic lug and collar) | 0.5 mm² ... 10 mm² |
| Insulation Material Relative Temperature Index (Elec., UL 746 B) | 130 °C |
| Flexible conductor cross-section (cable lug without insulation collar) | 0.5 mm² ... 10 mm² |
| Temperature index for insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
| 2 conductors of identical cross-section flexible with TWIN ferrule with plastic collar | 1.5 mm² ... 4 mm² |