| Parameter | Value |
|---|---|
| Step | 5 mm |
| Result | Approved Test |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Width [w] | 15 mm |
| frequency | 10 - 150 - 10 Hz |
| Height [h] | 13 mm |
| Length [l] | 2.8 mm |
| Pin Design | Linear Pin Arrangement |
| Observation | WEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Plug Cycles | 25 |
| Sweep speed | 1 octave/min |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Product Line | COMBICON Connectors M |
| Product Type | Male connector |
| Hole diameter | 1.3 mm |
| Article Review | 00 |
| Number of rows | 1 |
| Overall Height | 9.5 mm |
| Product Family | PST 1.3/.. -V |
| Thermal stress | 100 °C/168 h |
| Color (Housing) | Yellow (1018) |
| Number of poles | 3 |
| Test Directions | X, Y, and Z axes |
| Contact material | Cu Alloy |
| Dimension Scheme | |
| Number of cycles | 25 |
| Type of mounting | THR welding/wave welding |
| Corrosion fatigue | 0.2 dm3UNDER2in 300 dm3/40 °C/1 cycle |
| Temple Dimensions | ø 1.3 mm |
| Type of packaging | Boxed Packaging |
| Contact resistance | 1.6 mΩ |
| Nominal Current IN | 12 A (Depending on the connector used) |
| Nominal voltage UN | 320 V |
| Test Specification | DIN EN 60512-1-1:2003-01 |
| Bearable AC voltage | 2.21 kV |
| Insulating material | PA |
| Weld Pin Length [P] | 3.5 mm |
| Contact Resistance R1 | 1.6 mΩ |
| Contact Resistance R2 | 1.7 mΩ |
| Plug-in force approx. | 5 N |
| Nominal voltage (II/2) | 400 V |
| Number of poles tested | 12 |
| Sizing voltage (III/3) | 250 V |
| Test duration per axis | 2.5 h |
| Surface Characteristics | Galvanically tinned |
| Moisture Sensitive Level | MSL 1 |
| Insulating material group | IIIa |
| Welding cycles. by reflux | 3 |
| CTI according to IEC 60112 | 250 |
| Dimensioning voltage (III/2) | 320 V |
| Ambient Temperature (Service) | -40 °C ... 100 °C (depending on the rating curve) |
| Classification Temperature Tc | 260 °C |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Nominal transient voltage (II/2) | 4 kV |
| Sizing Insulation Voltage (II/2) | 400 V |
| Nominal transient voltage (III/2) | 4 kV |
| Nominal transient voltage (III/3) | 4 kV |
| Sizing Insulation Voltage (III/2) | 320 V |
| Sizing Insulation Voltage (III/3) | 250 V |
| Minimum creepage line value (II/2) | 4 mm |
| Bearable shock voltage at sea level | 4.8 kV |
| Metal surface weld area (top layer) | Tin (3 - 5 μm Sn) |
| Minimum creepage line value (III/2) | 3.2 mm |
| Minimum creepage line value (III/3) | 4 mm |
| Contact Holder UsedRequirement >20 N | Approved Test |
| Insulation Resistance Adjacent Poles | > 5 MΩ |
| Dimensioning transient voltage (II/2) | 4 kV |
| Flammability class according to UL 94 | V0 |
| Power when unplugging by pole approx. | 5 N |
| Dimensioning Transient Voltage (III/2) | 4 kV |
| Dimensioning transient voltage (III/3) | 4 kV |
| Metal surface contact area (top layer) | Tin (3 - 5 μm Sn) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Metal Surface Contact Area (Middle Layer) | Nickel (1 - 3 μm Ni) |
| Metal Surface Welding Area (Middle Layer) | Nickel (1 - 3 μm Ni) |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| Ball hardness test temperature according to EN 60695-10-2 | 125 °C |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI 250 |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 3 mm |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 3 mm |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 3 mm |
| Flammability number of GWFI incandescent filaments according to EN 60695-2-12 | 850 |
| Ignition temperature of incandescent filaments GWIT according to EN 60695-2-13 | 775 |
Technical specifications and performance data