Key Specifications
GTIN:4046356592000
Note:Made to Order (non-returnable)
Orderkey:2901417
Catalog page:Page 260 (C-6-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356592000
NoteMade to Order (non-returnable)
Orderkey2901417
Catalog pagePage 260 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
(Input data)6 A gL/gG NEOZED (N/C contact)
Height (Note)112 mm
(Output data)IP54
Country of originDE (Germany)
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)Surge protection Varistor
Net weight (Output data)99.9 g
Output fuse (Input data)10 A gL/gG NEOZED (N/O contact)
Relay type (Output data)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data)3 enabling current paths
Category (Connection data)4
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
Mounting type (Output data)DIN rail mounting
(Standards and Regulations)No hazardous substances above threshold values
Contact material (Input data)AgSnO2, + 0.2 µm Au
Designation (Connection data)EN 50156
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Sq. Total current (Input data)72 A2
Mounting position (Output data)any
Stop category (Connection data)0
Degree of protection (Output data)IP20
Recovery time (Ambient conditions)1 s
Maximum inrush current (Input data)6 A
Status display (Ambient conditions)Green LED
Inrush current, minimum (Input data)10 mA
Mechanical service life (Input data)approx. 107cycles
Nominal operating mode (Output data)100% operating factor
Switching capacity min. (Input data)100 mW
Weight per Piece (excluding packing)99.900 g
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Maximum switching voltage (Input data)250 V AC/DC
Minimum switching voltage (Input data)10 V AC/DC
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Protective circuit (Ambient conditions)Surge protection Varistor 275 VRMS(A1-A2)
Input voltage range (Ambient conditions)42 V AC/DC ... 48 V AC/DC
Limiting continuous current (Input data)6 A (N/O contact)
Performance level (PL) (Connection data)e
Typical release time (Ambient conditions)90 ms (when controlled via A1)
Concurrence input 1/2 (Ambient conditions)
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g
Typical response time (Ambient conditions)40 ms (man. start)
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Utilization restriction (Key Commercial Data)1
Operating voltage display (Ambient conditions)Green LED
Safety Integrity Level (SIL) (Connection data)3
Switching capacity (360/h cycles) (Input data)6 A (24 V DC)
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Typ. starting time with Us (Ambient conditions)330 ms (when controlled via A1)
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Maximum switching frequency (Ambient conditions)0.5 Hz
Typical input current at UN (Ambient conditions)95 mA
Interrupting rating (ohmic load) max. (Input data)144 W (24 V DC, τ = 0 ms)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Degree of pollution (Safety-related characteristic data)2
Maximum interrupting rating (inductive load) (Input data)48 W (24 V DC, τ = 40 ms)
Min. degree of protection of inst. location (Output data)IP54
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178/VDE 0160
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g
Input voltage range in reference to UN (Ambient conditions)0.85 ... 1.1
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3
Voltage at input/start and feedback circuit (Ambient conditions)~ 24 V DC
Max. permissible overall conductor resistance (Ambient conditions)50 Ω
Rated surge voltage/insulation (Safety-related characteristic data)4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths)

Product Description

Safety relay for emergency stop monitoring and safety doors up to SIL 3 or cat. 4, PL e according to EN ISO 13849, single-channel or two-channel operation, 3 trip circuits, nominal input voltage: 42 .
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top