Service time: Monday to Friday 9:00-18:00
PSR-SPP- 24UC/URM4/5X1/2X2 - PSR-SPP- 24UC/URM4/5X1/2X2 2964005 PHOENIX CONTACT Extension module
In Stock Hot Product

PSR-SPP- 24UC/URM4/5X1/2X2

PSR-SPP- 24UC/URM4/5X1/2X2 2964005 PHOENIX CONTACT Extension module

$0.00USD
3284 in stock
Key Specifications
GTIN:4017918904739
Orderkey:2964005
Catalog page:Page 263 (C-6-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918904739
Orderkey2964005
Catalog pagePage 263 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)35 mm
(Input data)C6 (24 V AC/DC) automatic device
Height (Note)112 mm
(Output data)IP54
Country of originDE (Germany)
pluggable (General)Yes
Custom tariff number85371098
Net weight (Output data)270.18 g
Output fuse (Input data)6 A fast blow
Relay type (Output data)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data)5 enabling current paths
Category (Connection data)4 (In conjunction with suitable evaluating device)
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
Housing color (Output data)yellow
Mounting type (Output data)DIN rail mounting
(Standards and Regulations)No hazardous substances above threshold values
Contact material (Input data)AgSnO2, + 0.2 µm Au
Designation (Connection data)EN 62061
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Sq. Total current (Input data)72 A2(ITH2= I12+ I22+ ... + I52)
Mounting position (Output data)any
Stop category (Connection data)0
Degree of protection (Output data)IP20
Maximum inrush current (Input data)6 A
Status display (Ambient conditions)Green LED
Inrush current, minimum (Input data)25 mA
Mechanical service life (Input data)approx. 107cycles
Nominal operating mode (Output data)100% operating factor
Switching capacity min. (Input data)0.4 W
Weight per Piece (excluding packing)270.180 g
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Maximum switching voltage (Input data)250 V AC/DC
Minimum switching voltage (Input data)15 V AC/DC
Protective circuit (Ambient conditions)Surge protection Suppressor diode
Limiting continuous current (Input data)6 A (N/O contact)
Performance level (PL) (Connection data)e (In conjunction with suitable evaluating device)
Typical release time (Ambient conditions)20 ms
Concurrence input 1/2 (Ambient conditions)
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g
Typical response time (Ambient conditions)20 ms
Ambient temperature (operation) (Dimensions)-20 °C ... 55 °C
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Nominal input voltage UN (Ambient conditions)24 V AC/DC
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Safety Integrity Level (SIL) (Connection data)3 (In conjunction with suitable evaluating device)
Switching capacity (360/h cycles) (Input data)4 A (24 V DC)
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Typical input current at UN (Ambient conditions)47 mA (per channel)
Interrupting rating (ohmic load) max. (Input data)144 W (24 V DC, τ = 0 ms, N/C contact 11/12: 72 W)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 70 °C
Degree of pollution (Safety-related characteristic data)2
Maximum interrupting rating (inductive load) (Input data)42 W (24 V DC, τ = 40 ms)
Min. degree of protection of inst. location (Output data)IP54
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178/VDE 0160
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g
Input voltage range in reference to UN (Ambient conditions)0.8 ... 1.1
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)
Rated insulation voltage (Safety-related characteristic data)250 V
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3 (In conjunction with suitable evaluating device)
Rated surge voltage/insulation (Safety-related characteristic data)4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths(43/44, 53/54, 63/64, 71/72) and between 43/44, 53/54, 63/64, 71/72 themselves.)

Product Description

Extension of single- or two-channel contacts, 5 normally open contacts, 1 normally closed contact, 1 feedback circuit, together with base device safe separation up to category 4 PL e according to EN I
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top