Key Specifications
:High demand
Depth:112 mm
Shock:15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.)
Width:22.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
High demand
Depth112 mm
Shock15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.)
Width22.5 mm
Height114.5 mm
Category1
pluggableyes
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
ApplicationSafe switch off
CertificateCE-compliant
Output fuse10 A gL/gG (N/O contact)
Product typeCoupling relay
Restart time< 1 s (Boot time)
Mounting typeDIN rail mounting
Recovery time< 500 ms
Stop category0
Inrush currenttyp. 350 mA DC (Δt s)
Product familyPSRclassic
Color (Housing)yellow (RAL 1018)
Article revision06
Contact materialAgSnO2
Housing materialPolyamide
Maximum altitudemax. 2000 m (Above sea level)
Stripping length8 mm
Connection methodPush-in connection
Mounting positionvertical or horizontal
Sq. Total current48 A2
Tightening torque0.6 Nm
Protective circuitSurge protection; Suppressor diode
Switching capacitymin. 50 mW
Input voltage range20.4 V AC/DC ... 26.4 V AC/DC
Note on applicationOnly for industrial use
Degree of protectionIP20
Typical release timetyp. 15 ms (when controlled via A1)
Standards/regulationsDIN EN 50178
Vibration (operation)10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)
Contact switching type3 enabling current paths
Maximum inrush current8 A
Nominal operating mode100% operating factor
Performance level (PL)c
Inrush current, minimum10 mA
Mechanical service life10x 106cycles
Power consumption at UStyp. 1.08 W
Rated insulation voltage250 V
Maximum switching voltage230 V AC/DC (Observe the load curve)
Minimum switching voltage5 V AC/DC
Operating voltage display1 x green LED
Typ. starting time with Ustyp. 15 ms (when controlled via A1)
Conductor cross-section AWG24 ... 16
Limiting continuous current6 A (N/O contact)
Maximum switching frequency0.5 Hz
Safety Integrity Level (SIL)1
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Rated surge voltage/insulation4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.)
Ambient temperature (operation)-20 °C ... 55 °C
Rated control supply current IStyp. 45 mA
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Interrupting rating (ohmic load) max.For additional values, see load curve
Ambient temperature (storage/transport)-40 °C ... 70 °C
Rated control circuit supply voltage US20.4 V AC/DC ... 26.4 V AC/DC
Min. degree of protection of inst. locationIP54
Maximum interrupting rating (inductive load)48 W (N/O contact, 24 V DC, τ = 40 ms)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Maximum power dissipation for nominal condition6.11 W (at UB= 26.4 V DC, US= 24 V, IS= 45 mA, n = 1, IL² = 48 A², Rcontact= 0.1 )
Switching capacity in accordance with IEC 60947-5-15 A (24 V (DC13))
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Product Description

Safe coupling relay with forced-conduction contacts, 3 NO contacts, 3 NC contacts, width: 22.5 mm, plug-in push-in terminal block
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top