| Parameter | Value |
|---|---|
| GTIN | 4046356451369 |
| (Times) | IP54 |
| Orderkey | 2986041 |
| Catalog page | Page 294 (C-6-2017) |
| Depth (Note) | 114.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 22.5 mm |
| Height (Note) | 112 mm |
| Country of origin | DE (Germany) |
| (Connection data) | 3 (2-channel parameterization) |
| Net weight (Times) | 130 g |
| pluggable (General) | Yes |
| Custom tariff number | 85364900 |
| (Ambient conditions) | typ. 66 mA (All inputs and safe outputs set) |
| Housing color (Times) | yellow |
| Mounting type (Times) | DIN rail mounting |
| Housing material (Times) | Polyamide PA non-reinforced |
| Mounting position (Times) | On horizontal DIN rail |
| Voltage (Digital outputs) | 24 V DC (Supply via A1/A2) |
| Category (Connection data) | 2 (1-channel parameterization) |
| Stripping length (General) | 8 mm |
| Cable length (Power supply) | max. 2000 m |
| Connection method (General) | Spring-cage connection |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Degree of protection (Times) | IP20 |
| Test pulses (Digital inputs) | < 1 ms |
| Designation (Connection data) | EN 50156 |
| Maximum altitude (Dimensions) | max. 2000 m (See Appendix "Using PSR-TRISAFE modules at altitudes greater than 2000 m above sea level") |
| Status display (Power supply) | 12 LEDs (green) |
| Test pulses (Digital outputs) | ~ 1 ms |
| Nominal operating mode (Times) | 100% operating factor |
| Number of inputs (Power supply) | 12 (Of which 4 can be configured as input or output) |
| Status display (Digital inputs) | 4x LED green |
| Stop category (Connection data) | 0 |
| Filter time (Ambient conditions) | typ. 20 ms (Load-dependent, in the event of voltage dips at US) |
| Current consumption (Power supply) | typ. 4 mA |
| Number of outputs (Digital inputs) | 4 (If the configurable inputs/outputs are used as outputs) |
| Number of outputs (Digital outputs) | 2 |
| Status display (Ambient conditions) | 1 x green LED, 1 x red LED |
| Max. inductive load (Digital inputs) | See "Protective circuit" |
| Output description (Digital outputs) | Digital |
| Recovery time (Clock/signal outputs) | < 10 s |
| Response time (Clock/signal outputs) | max. 30 ms (plus response time of PSR-TS-SDOR4) |
| Weight per Piece (excluding packing) | 130.000 g |
| (Safety-related characteristic data) | 10g (Δt = 16 ms, continuous shock, 1000 shocks in each space direction) |
| Air pressure (operation) (Dimensions) | 70 kPa ... 108 kPa (up to 3000 m above sea level) |
| Max. capacitive load (Digital inputs) | max. 1 µF (Electronic components) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Description of the input (Power supply) | Digital input |
| Nominal output voltage (Digital inputs) | 24 V DC (Supply via A1/A2) |
| Protective circuit (Ambient conditions) | Yes, within the scope of the operating voltage limits |
| Performance level (PL) (Connection data) | d (1-channel parameterization) |
| Short-circuit protection (Digital inputs) | Yes |
| Conductor cross section AWG max. (General) | 16 |
| Conductor cross section AWG min. (General) | 24 |
| Short-circuit protection (Digital outputs) | Yes |
| Note on protection circuit (Digital inputs) | Yes, within the scope of the operating voltage limits |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 55 °C |
| Conductor cross section solid max. (General) | 1.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Air pressure (storage/transport) (Dimensions) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Input voltage range "0" signal (Power supply) | 0 V DC ... 5 V DC (for safe Off) |
| Input voltage range "1" signal (Power supply) | 11 V DC ... 30 V DC |
| Limiting continuous current (Digital outputs) | 50 mA |
| Nominal output voltage range (Digital inputs) | 18 V DC ... 30 V DC (Incl. all tolerances, incl. residual ripple) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Safety Integrity Level (SIL) (Connection data) | max. 3 (Reference IEC 61508) |
| Conductor cross section flexible max. (General) | 1.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Designation (Safety-related characteristic data) | Air clearances and creepage distances between the power circuits |
| Min. degree of protection of inst. location (Times) | IP54 |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 70 °C |
| Rated control supply current IS (Ambient conditions) | Electrical supply via PSR-TBUS |
| Shock (operation) (Safety-related characteristic data) | 10g (Δt = 11 ms, three shocks in each space direction) |
| Degree of pollution (Safety-related characteristic data) | 2 |
| Overvoltage category (Safety-related characteristic data) | III |
| Max. permissible humidity (storage/transport) (Dimensions) | 75 % (On average, 85 % occasionally) |
| Standards/regulations (Safety-related characteristic data) | DIN EN 50178 |
| Vibration (operation) (Safety-related characteristic data) | 2g |
| Max. permissible relative humidity (operation) (Dimensions) | 75 % (On average, 85 % occasionally) |
| Rated control circuit supply voltage US (Ambient conditions) | 24 V DC (Electrical supply via PSR-TBUS) |
| Safety Integrity Level Claim Limit (SIL CL) (Connection data) | 2 (1-channel parameterization) |
Technical specifications and performance data
Installation and operation guide