| Parameter | Value |
|---|---|
| GTIN | 4046356325998 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2981949 |
| Catalog page | Page 265 (C-6-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| pluggable (General) | Yes |
| Custom tariff number | 85364190 |
| Designation (Supply) | Air clearances and creepage distances between the power circuits |
| Status display (Supply) | Green LED |
| Mounting position (Supply) | any |
| Stripping length (General) | 8 mm |
| Connection method (General) | Spring-cage connection |
| Depth (Key Commercial Data) | 106 mm |
| Width (Key Commercial Data) | 22.5 mm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Degree of pollution (Supply) | 2 |
| Height (Key Commercial Data) | 117 mm |
| Designation (Connection data) | Air clearances and creepage distances between the power circuits |
| Overvoltage category (Supply) | III |
| Assembly instructions (Supply) | In rows with zero spacing |
| Standards/regulations (Supply) | DIN EN 50178 |
| Nominal operating mode (Supply) | 100% operating factor |
| Degree of protection (Dimensions) | IP20 |
| Max. permissible current (Supply) | 100 mA (per signal output) |
| Rated insulation voltage (Supply) | 50 V DC |
| Weight per Piece (excluding packing) | 99.990 g |
| Degree of pollution (Connection data) | 2 |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Overvoltage category (Connection data) | III |
| Max. permissible total current (Supply) | 100 mA (alarm outputs) |
| Rated surge voltage/insulation (Supply) | 0.8 kV |
| Standards/regulations (Connection data) | DIN EN 50178 |
| Conductor cross section AWG max. (General) | 16 |
| Conductor cross section AWG min. (General) | 24 |
| Rated insulation voltage (Connection data) | 50 V DC |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 55 °C |
| Conductor cross section solid max. (General) | 1.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Nominal input voltage UN (Ambient conditions) | 24 V DC (from PSR) |
| Conductor cross section flexible max. (General) | 1.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Rated surge voltage/insulation (Connection data) | 0.8 kV |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 70 °C |
| Input voltage range in reference to UN (Ambient conditions) | 0.85 ... 1.1 |
Technical specifications and performance data
Installation and operation guide