Key Specifications
GTIN:4046356051699
Orderkey:2981499
Catalog page:Page 262 (C-6-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356051699
Orderkey2981499
Catalog pagePage 262 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
(Input data)Miniature circuit breaker C6 (24 V / 20 A power supply unit)
Height (Note)112 mm
(Output data)IP54
Country of originDE (Germany)
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)150 ms (automatic start)
Net weight (Output data)197.9 g
Output fuse (Input data)10 A gL/gG NEOZED (N/O contact)
Relay type (Output data)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data)2 enabling current paths
Category (Connection data)4 (Undelayed contacts)
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
Housing color (Output data)yellow
Mounting type (Output data)DIN rail mounting
(Standards and Regulations)No hazardous substances above threshold values
Contact material (Input data)AgSnO2
Designation (Connection data)EN 62061
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Mounting position (Output data)any
Stop category (Connection data)0
Degree of protection (Output data)IP20
Recovery time (Ambient conditions)1 s
Maximum inrush current (Input data)6 A
Inrush current, minimum (Input data)25 mA
Mechanical service life (Input data)approx. 107cycles
Nominal operating mode (Output data)100% operating factor
Switching capacity min. (Input data)0.4 W
Weight per Piece (excluding packing)197.900 g
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Maximum switching voltage (Input data)250 V AC/DC
Minimum switching voltage (Input data)15 V AC/DC
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Limiting continuous current (Input data)6 A (N/O contact)
Performance level (PL) (Connection data)e
Typical release time (Ambient conditions)10 ms
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Typical response time (Ambient conditions)20 ms (manual start)
Ambient temperature (operation) (Dimensions)-20 °C ... 55 °C
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Nominal input voltage UN (Ambient conditions)24 V DC
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Safety Integrity Level (SIL) (Connection data)3
Switching capacity (360/h cycles) (Input data)6 A (24 V DC)
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Typical input current at UN (Ambient conditions)70 mA
Interrupting rating (ohmic load) max. (Input data)144 W (24 V DC, τ = 0 ms)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 70 °C
Degree of pollution (Safety-related characteristic data)2
Maximum interrupting rating (inductive load) (Input data)48 W (24 V DC, τ = 40 ms)
Min. degree of protection of inst. location (Output data)IP54
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178/VDE 0160
Input voltage range in reference to UN (Ambient conditions)0.85 ... 1.1
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)
Rated insulation voltage (Safety-related characteristic data)250 V
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3
Voltage at input/start and feedback circuit (Ambient conditions)approx. 24 V DC
Max. permissible overall conductor resistance (Ambient conditions)50 Ω (Input and start circuits at UN)
Rated surge voltage/insulation (Safety-related characteristic data)4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.)

Product Description

Safety relay for emergency stop switch, safety and magnetic doors as well as for light curtains, up to SIL 3 or cat. 4, PL e according to EN ISO 13849, 2 NO contacts, TBUS interface, automatic or manu
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified