| Parameter | Value |
|---|---|
| EAN | Four trillion forty six billion three hundred fifty six million ninety one thousand seven hundred forty nine |
| Key order | Two million nine hundred eighty one thousand six hundred ninety three |
| Key selling | DNA24X - |
| Packing unit | 1 pcs |
| (Data entry) | 500 VA (250 V AC, τ = 0 ms) |
| (Outputs notice) | IP54 |
| Country of origin | DE (Germany) |
| plug-in (Overview) | yes |
| Depth (Observation) | 114.5 mm |
| Width (Observation) | 22.5 mm |
| Height (Observation) | 112 mm |
| Tariff number tariff | Ninety million three hundred twenty eight thousand nine hundred |
| Voltage (Output data) | 24 V DC |
| Name (Data connection) | En 62061 |
| Output fuse (Data entry) | 6 To gL |
| Category (Data connection) | Three |
| (Environmental conditions) | Limitation of voltage ≥ 33 V PTC Resistance |
| Height of fixing (Measures) | max. 2000 m (via NN) |
| Length desaislar (Overview) | 8 mm |
| Net weight (Outputs notice) | 176,8 g |
| Mechanical life (Data entry) | 1x 10Sevenoperations |
| Type of contact (Data entry) | 1 firing circuit |
| Contact Material (Data entry) | AgNi, + 5 µm Au |
| Type of connection (Overview) | Connection by spring |
| Color housing (Outputs notice) | yellow |
| Mounting type (Outputs notice) | Mounting on a rail |
| Type of relay (Outputs notice) | Electromechanical relay with contacts driving enforced according to en 50205 |
| (Standards and specifications) | No dangerous substances above the thresholds |
| Number of outputs (Output data) | 2 (MO / fOut) |
| Stop category (Data connection) | Zero |
| Unit weight (excluding packaging) | 176,800 g |
| Constant current limit (Data entry) | 2 A (open contact) |
| Constant current limit (Output data) | 100 mA |
| Current minimum closing (Data entry) | 1 mA |
| Index of protection (Outputs notice) | IP20 |
| Restriction of use (Data commercial) | EMC: class A product, see manufacturer's declaration in the download center |
| Name (Technical parameters of safety) | Lines of flight and air spaces between the circuits |
| Room temperature (service) (Measures) | -10 °C ... 60 °C |
| Breaking capacity minimum (Data entry) | 60 mW |
| Switching voltage maximum (Data entry) | 250 V AC/DC |
| Current maximum connection (Data entry) | 2 A (open contact) |
| Core cross-section rigid min. (Overview) | 0,2 mm2 |
| Performance Level (PL) (Data connection) | d |
| Section of conductor AWG max. (Overview) | Sixteen |
| Section of conductor AWG min. (Overview) | Twenty four |
| China RoHS (Standards and specifications) | Space of time for the intended use: unlimited = FEUP-e |
| Position to the mounting (Outputs notice) | discretionary |
| Frequency limit (Environmental conditions) | 1 kHz |
| Minimum voltage of activation (Data entry) | 0.1 V AC/DC |
| Section of conductor rigid max. (Overview) | 1.5 mm2 |
| Type of operation nominal (Outputs notice) | Working time 100 % |
| Circuit protection (Environmental conditions) | Prot. surge suppressor Diode |
| Section of flexible conductor max. (Overview) | 1.5 mm2 |
| Safety Integrity Level (SIL) (Data connection) | Two |
| Section of flexible conductor, min. (Overview) | 0,2 mm2 |
| Category surge (Technical parameters of safety) | II |
| Pollution degree (Technical parameters of safety) | Two |
| Rated voltage input OrN (Environmental conditions) | 24 V DC (PELV) |
| Ambient temperature (storage / transport) (Measures) | -40 °C ... 70 °C |
| Breaking capacity (resistive load) maximum (Data entry) | 48 W (24 V DC, t = 0 ms) |
| Input current typical with UN (Environmental conditions) | 70 mA DC |
| Isolation voltage design (Technical parameters of safety) | 250 V |
| Standards/specifications (Technical parameters of safety) | DIN EN 50178/VDE 0160 |
| Safety Integrity Level Claim Limit (SIL CL) (Data connection) | Two |
| Indication of the operating voltage (Environmental conditions) | Green LED |
| Input voltage range referred to OrN (Environmental conditions) | 0,85 ... 1,1 |
| Supply voltage rated control circuit OrS (Environmental conditions) | |
| Degree of protection minimum of the place of assembly (Outputs notice) | IP54 |
| Transient voltage design / insulation (Technical parameters of safety) | 4 kV / basic insulation |