Service time: Monday to Friday 9:00-18:00
PSR-SPP-24DC/ESP4/2X1/1X2 - PSR-SPP- 24DC/ESP4/2X1/1X2 2981017 PHOENIX CONTACT Safety relays
In Stock Hot Product

PSR-SPP-24DC/ESP4/2X1/1X2

PSR-SPP- 24DC/ESP4/2X1/1X2 2981017 PHOENIX CONTACT Safety relays

$0.00USD
4571 in stock
Key Specifications
:Process technology
Depth:114.5 mm
Shock:15g
Width:22.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Process technology
Depth114.5 mm
Shock15g
Width22.5 mm
Height112 mm
Category4
pluggableyes
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
ApplicationEmergency stop
Filter timemax. 3 ms (Test pulse width of low test pulses)
Output fuse10 A gL/gG
Product typeSafety relays
Restart time< 1 s (Boot time)
Mounting typeDIN rail mounting
Recovery time≥ 1 s (following demand of the safety function)
Stop category0
IdentificationCE-compliant
Inrush currentmax. 1 A (typ. with US, Δt =
Product familyPSRclassic
Status displayLED (green)
Color (Housing)yellow (RAL 1018)
Article revision08
Contact materialAgSnO2
Housing materialPolyamide
Maximum altitude≤ 2000 m (Above sea level)
Number of inputs1
Stripping length8 mm
Connection methodPush-in connection
Mounting positionOn horizontal and vertical DIN rail
Number of outputs2
Sq. Total current72 A2(observe derating)
Switching voltagemin. 10 V
Output description2 N/O contacts each in series, safety-related, floating
Protective circuitSuppressor diode
Switching capacitymin. 100 mW
Current consumption65 mA (typ. with US)
Note on applicationOnly for industrial use
Switching frequencymax. 0.5 Hz
Degree of protectionIP20
Typical release timetyp. 20 ms (At Us/on demand via A1)
Standards/regulationsDIN EN 60947-1
Typical response timetyp. 60 ms (For Usmanual, monitored start)
Vibration (operation)10 Hz ... 150 Hz, 2g
Contact switching type2 enabling current paths
Nominal operating mode100% operating factor
Performance level (PL)e
Mechanical service lifeapprox. 107cycles
Description of the inputsafety-related
Rated insulation voltage250 V
Operating voltage displayGreen LED
Typ. starting time with Us60 ms (At Us/on demand via A1)
Conductor cross-section AWG24 ... 16
Limiting continuous current6 A (Observe derating and load limit curve)
Safety Integrity Level (SIL)3
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Input voltage range "1" signal20.4 V ... 26.4 V
Rated surge voltage/insulationSee section “Insulation coordination”
Ambient temperature (operation)-20 °C ... 55 °C (observe derating)
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Interrupting rating (ohmic load) max.Observe derating and load limit curve
Ambient temperature (storage/transport)-40 °C ... 70 °C
Min. degree of protection of inst. locationIP54
Maximum interrupting rating (inductive load)Observe derating and load limit curve
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistance50 Ω
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Maximum power dissipation for nominal condition16.12 W (At US= 26.4 V, IL² = 72 A², PTotal max= 1.72 W + 14.4 W)
Switching capacity in accordance with IEC 60947-5-15 A (AC15)
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Product Description

Safety relay for SIL 3 high- and low-demand applications, also approved according to EN 50156, Germanischer Lloyd and EN ISO 13849, emergency stop and safety door monitoring, single-channel, 2 trip ci
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top