PSR-SPP-24DC/ESD/5X1/1X2/T10S - PSR-SPP- 24DC/ESD/5X1/1X2/T10S 2981509 PHOENIX CONTACT Safety relays
In Stock Hot Product

PSR-SPP-24DC/ESD/5X1/1X2/T10S

PSR-SPP- 24DC/ESD/5X1/1X2/T10S 2981509 PHOENIX CONTACT Safety relays

$0.00USD
3126 in stock
Key Specifications
GTIN:4017918981105
Orderkey:2981509
Depth (Note):114.5 mm
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918981105
Orderkey2981509
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)45 mm
(Input data)6 A gL/gG (N/C contact)
Height (Note)112 mm
(Output data)IP54
Country of originDE (Germany)
(Connection data)3 (delayed contacts)
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)Test pulse rate = 5 x Test pulse width
Net weight (Output data)452 g
Output fuse (Input data)10 A gL/gG (N/O contact)
Relay type (Output data)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data)5 enabling current paths
Category (Connection data)4 (Undelayed contacts)
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
Housing color (Output data)yellow
Mounting type (Output data)DIN rail mounting
(Standards and Regulations)No hazardous substances above threshold values
Contact material (Input data)AgSnO2
Designation (Connection data)EN 62061
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Housing material (Output data)PBT
Sq. Total current (Input data)55 A2(observe derating)
Delay time (Ambient conditions)K3(t), K4(t) fixed depending on model
Mounting position (Output data)any
Stop category (Connection data)0
Filter time (Ambient conditions)1 ms (at A1 in the event of voltage dips at Us)
Degree of protection (Output data)IP20
Recovery time (Ambient conditions)< 1 s
Inrush current (Ambient conditions)200 mA (at US)
Maximum inrush current (Input data)20 A (Δt  100 ms, undelayed contacts)
Status display (Ambient conditions)4 x green LEDs
Inrush current, minimum (Input data)10 mA
Mechanical service life (Input data)10x 106cycles
Nominal operating mode (Output data)100% operating factor
Switching capacity min. (Input data)50 mW
Weight per Piece (excluding packing)452.000 g
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Maximum switching voltage (Input data)250 V AC/DC (Observe the load curve)
Minimum switching voltage (Input data)5 V AC/DC
Protective circuit (Ambient conditions)Surge protection Suppressor diode
Current consumption (Ambient conditions)< 40 mA (with Us/Ixto S10)
Limiting continuous current (Input data)6 A (N/O contact, pay attention to the derating)
Performance level (PL) (Connection data)e (for delayed contacts PL d)
Typical release time (Ambient conditions)< 20 ms (when controlled via S11/S12 and S21/S22)
Concurrence input 1/2 (Ambient conditions)
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g
Typical response time (Ambient conditions)< 600 ms (automatic start)
Ambient temperature (operation) (Dimensions)-20 °C ... 55 °C (observe derating)
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Power consumption at US (Ambient conditions)typ. 3.6 W
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Operating voltage display (Ambient conditions)1 x green LED
Safety Integrity Level (SIL) (Connection data)3 (for delayed contacts SIL 2)
Switching capacity (360/h cycles) (Input data)4 A (24 V DC)
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Typ. starting time with Us (Ambient conditions)< 600 ms (when controlled via A1)
Conformance (Safety-related characteristic data)CE-compliant
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Maximum switching frequency (Ambient conditions)0.5 Hz
Interrupting rating (ohmic load) max. (Input data)144 W (24 V DC, τ = 0 ms)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 70 °C
Rated control supply current IS (Ambient conditions)typ. 150 mA
Degree of pollution (Safety-related characteristic data)2
Maximum interrupting rating (inductive load) (Input data)42 W (24 V DC, τ = 40 ms, delayed contacts: 48 W)
Min. degree of protection of inst. location (Output data)IP54
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178/VDE 0160
Vibration (operation) (Safety-related characteristic data)10 Hz ...150 Hz, 2g
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)24 V DC -15 % / +10 %
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3 (for delayed contacts SILCL 2)
Voltage at input/start and feedback circuit (Ambient conditions)24 V DC -15 % / +10 %
Max. permissible overall conductor resistance (Ambient conditions)approx. 11 Ω (Input and start circuits at US)
Rated surge voltage/insulation (Safety-related characteristic data)Basic insulation 4 kV:between all current paths and housingSafe isolation, reinforced insulation 6 kV:between 13/14, 23/24, 33/34, and the remaining current pathsbetween 13/14, 23/24, 33/34 among one another

Product Description

Safety relay for emergency stop monitoring and safety doors up to SIL 3 or cat. 4, PLe according to EN ISO 13849, automatic or manual activation, 3 NO contacts, 1 NC contact, 2 NO contacts with 10.0 s
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top