Service time: Monday to Friday 9:00-18:00
PSR-SPP-24DC/ESD/4X1/30 - PSR-SPP- 24DC/ESD/4X1/30 2981813 PHOENIX CONTACT Safety relays
In Stock Hot Product

PSR-SPP-24DC/ESD/4X1/30

PSR-SPP- 24DC/ESD/4X1/30 2981813 PHOENIX CONTACT Safety relays

$0.00USD
4677 in stock
Key Specifications
GTIN:4046356117265
Orderkey:2981813
Catalog page:Page 261 (C-6-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356117265
Orderkey2981813
Catalog pagePage 261 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
(Input data)23 W (220 V DC, τ = 40 ms)
Height (Note)112 mm
(Output data)IP54
Country of originDE (Germany)
(Connection data)1
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)1 s (Electric torque)
Net weight (Output data)166.88 g
Output fuse (Input data)10 A gL/gG NEOZED (N/O contact)
Relay type (Output data)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data)4 enabling current paths
Category (Connection data)4
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
Mounting type (Output data)DIN rail mounting
(Standards and Regulations)No hazardous substances above threshold values
Contact material (Input data)AgSnO2
Designation (Connection data)EN ISO 13849
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Sq. Total current (Input data)120 A2(see to derating)
Mounting position (Output data)any
Stop category (Connection data)0
Degree of protection (Output data)IP20
Recovery time (Ambient conditions)330 ms (Restart)
Maximum inrush current (Input data)6 A
Status display (Ambient conditions)LED K1/K2 and K3(t)/K4(t), green
Inrush current, minimum (Input data)25 mA
Mechanical service life (Input data)approx. 107cycles
Nominal operating mode (Output data)100% operating factor
Switching capacity min. (Input data)0.4 W
Weight per Piece (excluding packing)166.880 g
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Maximum switching voltage (Input data)250 V AC/DC
Minimum switching voltage (Input data)15 V AC/DC
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Protective circuit (Ambient conditions)Suppressor diode, 33 V DC
Limiting continuous current (Input data)6 A (N/O contact)
Performance level (PL) (Connection data)e
Typical release time (Ambient conditions)20 ms (Undelayed contacts)
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g
Typical response time (Ambient conditions)150 ms (Monitored/manual and auto-start)
Ambient temperature (operation) (Dimensions)-20 °C ... 45 °C
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Nominal input voltage UN (Ambient conditions)24 V DC
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Operating voltage display (Ambient conditions)Green LED
Safety Integrity Level (SIL) (Connection data)3
Switching capacity (360/h cycles) (Input data)on request
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Typical release time range (Ambient conditions)0.1 s ... 30 s
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Typical input current at UN (Ambient conditions)75 mA DC
Interrupting rating (ohmic load) max. (Input data)144 W (24 V DC, τ = 0 ms)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 70 °C
Degree of pollution (Safety-related characteristic data)2
Maximum interrupting rating (inductive load) (Input data)42 W (24 V DC, τ = 40 ms)
Min. degree of protection of inst. location (Output data)IP54
Overvoltage category (Safety-related characteristic data)II
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 60947-1
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g
Input voltage range in reference to UN (Ambient conditions)0.85 ... 1.1
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)
Rated insulation voltage (Safety-related characteristic data)250 V
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3
Voltage at input/start and feedback circuit (Ambient conditions)approx. 24 V DC
Max. permissible overall conductor resistance (Ambient conditions)50 Ω (Input and reset circuit at UN)
Rated surge voltage/insulation (Safety-related characteristic data)4 kV / basic insulation

Product Description

Safety relay for emergency stop monitoring and safety doors up to SIL 3 or cat. 4, PLe according to EN ISO 13849, automatic or manual activation, 2 NO contacts with 0.1 s disconnect delay ... 30 s, pl
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide