| Parameter | Value |
|---|---|
| GTIN | 4046356117265 |
| Orderkey | 2981813 |
| Catalog page | Page 261 (C-6-2017) |
| Depth (Note) | 114.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 22.5 mm |
| (Input data) | 23 W (220 V DC, τ = 40 ms) |
| Height (Note) | 112 mm |
| (Output data) | IP54 |
| Country of origin | DE (Germany) |
| (Connection data) | 1 |
| pluggable (General) | Yes |
| Custom tariff number | 85371098 |
| (Ambient conditions) | 1 s (Electric torque) |
| Net weight (Output data) | 166.88 g |
| Output fuse (Input data) | 10 A gL/gG NEOZED (N/O contact) |
| Relay type (Output data) | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
| Contact type (Input data) | 4 enabling current paths |
| Category (Connection data) | 4 |
| Stripping length (General) | 8 mm |
| Connection method (General) | Spring-cage connection |
| Mounting type (Output data) | DIN rail mounting |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Contact material (Input data) | AgSnO2 |
| Designation (Connection data) | EN ISO 13849 |
| Maximum altitude (Dimensions) | ≤ 2000 m (Above sea level) |
| Sq. Total current (Input data) | 120 A2(see to derating) |
| Mounting position (Output data) | any |
| Stop category (Connection data) | 0 |
| Degree of protection (Output data) | IP20 |
| Recovery time (Ambient conditions) | 330 ms (Restart) |
| Maximum inrush current (Input data) | 6 A |
| Status display (Ambient conditions) | LED K1/K2 and K3(t)/K4(t), green |
| Inrush current, minimum (Input data) | 25 mA |
| Mechanical service life (Input data) | approx. 107cycles |
| Nominal operating mode (Output data) | 100% operating factor |
| Switching capacity min. (Input data) | 0.4 W |
| Weight per Piece (excluding packing) | 166.880 g |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Maximum switching voltage (Input data) | 250 V AC/DC |
| Minimum switching voltage (Input data) | 15 V AC/DC |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Protective circuit (Ambient conditions) | Suppressor diode, 33 V DC |
| Limiting continuous current (Input data) | 6 A (N/O contact) |
| Performance level (PL) (Connection data) | e |
| Typical release time (Ambient conditions) | 20 ms (Undelayed contacts) |
| Conductor cross section AWG max. (General) | 16 |
| Conductor cross section AWG min. (General) | 24 |
| Shock (Safety-related characteristic data) | 15g |
| Typical response time (Ambient conditions) | 150 ms (Monitored/manual and auto-start) |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 45 °C |
| Conductor cross section solid max. (General) | 1.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Operating voltage display (Ambient conditions) | Green LED |
| Safety Integrity Level (SIL) (Connection data) | 3 |
| Switching capacity (360/h cycles) (Input data) | on request |
| Conductor cross section flexible max. (General) | 1.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Typical release time range (Ambient conditions) | 0.1 s ... 30 s |
| Designation (Safety-related characteristic data) | Air clearances and creepage distances between the power circuits |
| Typical input current at UN (Ambient conditions) | 75 mA DC |
| Interrupting rating (ohmic load) max. (Input data) | 144 W (24 V DC, τ = 0 ms) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 70 °C |
| Degree of pollution (Safety-related characteristic data) | 2 |
| Maximum interrupting rating (inductive load) (Input data) | 42 W (24 V DC, τ = 40 ms) |
| Min. degree of protection of inst. location (Output data) | IP54 |
| Overvoltage category (Safety-related characteristic data) | II |
| Max. permissible humidity (storage/transport) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Standards/regulations (Safety-related characteristic data) | DIN EN 60947-1 |
| Vibration (operation) (Safety-related characteristic data) | 10 Hz ... 150 Hz, 2g |
| Input voltage range in reference to UN (Ambient conditions) | 0.85 ... 1.1 |
| Max. permissible relative humidity (operation) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Rated control circuit supply voltage US (Ambient conditions) | |
| Rated insulation voltage (Safety-related characteristic data) | 250 V |
| Safety Integrity Level Claim Limit (SIL CL) (Connection data) | 3 |
| Voltage at input/start and feedback circuit (Ambient conditions) | approx. 24 V DC |
| Max. permissible overall conductor resistance (Ambient conditions) | 50 Ω (Input and reset circuit at UN) |
| Rated surge voltage/insulation (Safety-related characteristic data) | 4 kV / basic insulation |
Technical specifications and performance data
Installation and operation guide