Service time: Monday to Friday 9:00-18:00
PSR-SPP-230AC/ESAM2/3X1/1X2/B - PSR-SPP-230AC/ESAM2/3X1/1X2/B 2901431 PHOENIX CONTACT Safety relays
In Stock Hot Product

PSR-SPP-230AC/ESAM2/3X1/1X2/B

PSR-SPP-230AC/ESAM2/3X1/1X2/B 2901431 PHOENIX CONTACT Safety relays

$0.00USD
3968 in stock
Key Specifications
GTIN:4046356592178
Orderkey:2901431
Catalog page:Page 260 (C-6-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356592178
Orderkey2901431
Catalog pagePage 260 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
(Input data)6 A gL/gG NEOZED (Signaling current paths)
Height (Note)112 mm
(Output data)IP54
Country of originDE (Germany)
(Connection data)1 (up to SIL 3 depending on the application)
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)Surge protection Varistor
Net weight (Output data)99.9 g
Output fuse (Input data)10 A gL/gG NEOZED (Enabling current paths)
Relay type (Output data)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data)3 enabling current paths
Category (Connection data)1 (up to Cat. 4 depending on the application)
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
Mounting type (Output data)DIN rail mounting
(Standards and Regulations)No hazardous substances above threshold values
Contact material (Input data)AgSnO2, gold-flashed
Designation (Connection data)EN ISO 13849
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Sq. Total current (Input data)72 A2
Mounting position (Output data)any
Stop category (Connection data)0
Degree of protection (Output data)IP20
Recovery time (Ambient conditions)1 s
Maximum inrush current (Input data)6 A
Status display (Ambient conditions)2 x green LEDs
Inrush current, minimum (Input data)10 mA
Mechanical service life (Input data)approx. 107cycles
Nominal operating mode (Output data)100% operating factor
Switching capacity min. (Input data)100 mW
Weight per Piece (excluding packing)99.900 g
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Maximum switching voltage (Input data)250 V AC/DC
Minimum switching voltage (Input data)10 V AC/DC
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Protective circuit (Ambient conditions)Surge protection Suppressor diode
Limiting continuous current (Input data)6 A (N/O contact)
Performance level (PL) (Connection data)c (up to PL e depending on the application)
Typical release time (Ambient conditions)20 ms (when controlled via S11/S12)
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g
Typical response time (Ambient conditions)50 ms (manual start)
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Nominal input voltage UN (Ambient conditions)230 V AC
Utilization restriction (Key Commercial Data)1
Operating voltage display (Ambient conditions)Green LED
Safety Integrity Level (SIL) (Connection data)1 (up to SIL 3 depending on the application)
Switching capacity (360/h cycles) (Input data)6 A (24 V DC)
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Typ. starting time with Us (Ambient conditions)300 ms (when controlled via A1 or S11/S12)
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Maximum switching frequency (Ambient conditions)0.5 Hz
Typical input current at UN (Ambient conditions)22 mA
Interrupting rating (ohmic load) max. (Input data)144 W (at 24 V DC)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Degree of pollution (Safety-related characteristic data)2
Maximum interrupting rating (inductive load) (Input data)48 W (at 24 V DC)
Min. degree of protection of inst. location (Output data)IP54
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178/VDE 0160
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g
Input voltage range in reference to UN (Ambient conditions)0.85 ... 1.1
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)1 (up to SILCL 3 depending on the application)
Voltage at input/start and feedback circuit (Ambient conditions)~ 24 V DC
Max. permissible overall conductor resistance (Ambient conditions)50 Ω
Rated surge voltage/insulation (Safety-related characteristic data)4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths)

Product Description

Safety relay for emergency stop and safety doors up to SIL 1, SIL CL 1, cat. 1, PL c, depending on the application up to SIL 3, SIL CL 3, cat. 4, PL e, single-channel operation, 3 trip circuits, nomin