Key Specifications
GTIN:4017918987794
Orderkey:2981457
Catalog page:Page 279 (C-6-2017)
Depth (Note):50.1 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918987794
Orderkey2981457
Catalog pagePage 279 (C-6-2017)
Depth (Note)50.1 mm
Packing unit1 pc
Width (Note)40 mm
(Input data)6 A gL/gG (N/C contact)
Height (Note)114.5 mm
Country of originDE (Germany)
pluggable (General)no
Custom tariff number85364900
Net weight (Output data)117 g
Output fuse (Input data)10 A gL/gG (N/O contact)
Relay type (Output data)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data)4 enabling current paths
Category (Connection data)1
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
Housing color (Output data)green
Mounting type (Output data)DIN rail mounting
(Standards and Regulations)No hazardous substances above threshold values
Contact material (Input data)AgSnO2
Designation (Connection data)EN ISO 13849
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Sq. Total current (Input data)72 A2
Mounting position (Output data)vertical or horizontal
Stop category (Connection data)0
Switching capacity (Input data)min. 50 mW
Degree of protection (Output data)IP20
Recovery time (Ambient conditions)< 500 ms
Maximum inrush current (Input data)6 A
Inrush current, minimum (Input data)10 mA
Mechanical service life (Input data)10x 106cycles
Nominal operating mode (Output data)100% operating factor
Weight per Piece (excluding packing)117.000 g
(Safety-related characteristic data)Basic insulation 4 kV between all output current paths
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Maximum switching voltage (Input data)230 V AC/DC (Observe the load curve)
Minimum switching voltage (Input data)5 V AC/DC
Limiting continuous current (Input data)6 A
Performance level (PL) (Connection data)c
Typical release time (Ambient conditions)typ. 10 ms (when controlled via A1)
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.)
Ambient temperature (operation) (Dimensions)-20 °C ... 55 °C
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Power consumption at US (Ambient conditions)typ. 1.25 W
Utilization restriction (Key Commercial Data)1
Operating voltage display (Ambient conditions)1 x green LED
Safety Integrity Level (SIL) (Connection data)1
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Typ. starting time with Us (Ambient conditions)typ. 10 ms (when controlled via A1)
Conformance (Safety-related characteristic data)CE-compliant
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Maximum switching frequency (Ambient conditions)0.5 Hz
Interrupting rating (ohmic load) max. (Input data)For additional values, see load curve
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Rated control supply current IS (Ambient conditions)typ. 52 mA
Degree of pollution (Safety-related characteristic data)2
Maximum interrupting rating (inductive load) (Input data)48 W (N/O contact, 24 V DC, τ = 40 ms)
Min. degree of protection of inst. location (Output data)IP54
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178
Switching capacity according to IEC 60947-5-1 (Input data)5 A (24 V (DC13))
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 2 ms.)
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)24 V AC/DC -20 % / +10 %
Rated insulation voltage (Safety-related characteristic data)250 V
Safety Integrity Level Claim Limit (SIL CL) (Connection data)1
Rated surge voltage/insulation (Safety-related characteristic data)Safe isolation, reinforced insulation 6 kV between input circuit (A1/A2) and all output current paths

Product Description

Secure coupling relay with forced-conduction contacts, 4 normally open contacts, 2 normally closed contacts, fixed spring connection terminal, width: 40 mm
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top