Key Specifications
:max. 250 V AC/DC
Link:Screw connection
Depth:114.5 mm
Shock:15g
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
max. 250 V AC/DC
LinkScrew connection
Depth114.5 mm
Shock15g
width22.5 mm
ThreadM3
height99 mm
MarkingCE Compliance
plug-inYes
Category4 (in combination with a suitable measuring device)
Relay TypeElectromagnetic relay with forcibly guided contacts according to IEC/EN 61810-3
Reset Time< 1 s
ApplicationExpansion module
Output fuse10 A gL/gG
Product TypeSafety Relays
Mounting typeRail Mounting
Stop category0
Product FamilyPSRclassic
Mechanical life10x 106Manoeuvring cycles
Contact materialAgSnO2
Housing MaterialPolyamide
Number of inputs1
Stripping length7 mm
Switchable powerMin. 100 mW
Duty cycle report100 % ED
Number of outputs5
Tightening torque0.5 Nm ... 0.6 Nm
Output Descriptioneach 2 NO in series, safe, potential-free
Protection CircuitDiode Suppressor
Switchable voltageMin. 10 V
Current consumptiontip. 75 mA
Switching frequencymax. 1 Hz
arit. Total current72 A2(take into account derating)
Degree of protectionIp20
Entrance descriptionSecurity-oriented
Standards/ProvisionsEN 60947-1
Installation LocationVertical or horizontal
Instantaneous currentMin. 10 mA
Typical Drop-Out Time< 20 ms (Us/command via A1)
Vibration (operation)10 Hz ... 150 Hz, 0.15 mm amplitude, 2g
Contact Switching Type5 safety contacts
Performance Level (PL)and (in combination with a suitable measuring device)
Permanent Load Current6 A (take into account derating)
Signal input range "1"19.2 V ... 26.4 V
Rated insulation voltage250 V
Installation instructionsSee Derating curve
AWG conductor cross-section24 ... 12
Operating voltage indication1 x Green LEDs
Safety Integrity Level (SIL)3 (in combination with a suitable measuring device)
Tip. Excitation time with Us< 25 ms (Us/command via A1)
Rigid conductor cross-section0.2 mm² ... 2.5 mm²
Ambient temperature (operating)-20 °C ... 55 °C (take into account derating)
Breaking capacity IEC 60947-5-13 A (AC15)
Flexible conductor cross-section0.2 mm² ... 2.5 mm²
Impulse voltage sizing/isolationSee chapter Insulation coordination
Max. permissible cable resistance25 Ω
Ambient temperature (storage/transport)-40 °C ... 70 °C
Maximum permissible humidity (operation)75 %
Max. humidity. Permitted (storage/transport)75 %
Degree of protection Installation location min.IP54
Maximum power dissipation under nominal conditions16.6 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.2 W + 14.4 W)

Product Description

Extension of 1 or 2 channel contacts, 5 NO contacts, 1 NC contact, 1 feedback loop, together with base equipment safe separation up to cat.4 PLe depending on ENISO13849, width: 22.5mm, plug-in screw t
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top