Service time: Monday to Friday 9:00-18:00
PSR-SCP-24DC/TS/SDOR4/4X1 - PSR-SCP- 24DC/TS/SDOR4/4X1 2986096 PHOENIX CONTACT Extension module
In Stock Hot Product

PSR-SCP-24DC/TS/SDOR4/4X1

PSR-SCP- 24DC/TS/SDOR4/4X1 2986096 PHOENIX CONTACT Extension module

$0.00USD
3330 in stock
Key Specifications
GTIN:4046356536554
(Times):IP54
Orderkey:2986096
(General):5 lbf-in. ... 7 lbf-in.
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356536554
(Times)IP54
Orderkey2986096
(General)5 lbf-in. ... 7 lbf-in.
Catalog pagePage 294 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
Height (Note)99 mm
(Power supply)4 A (gL/gG for low-demand applications)
Torque (General)0.5 Nm ... 0.6 Nm
Country of originDE (Germany)
(Connection data)3 (2-channel parameterization)
Net weight (Times)220 g
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)54 mA (At 24 V DC, relay outputs not set)
Housing color (Times)yellow
Mounting type (Times)DIN rail mounting
Screw thread (General)M3
Housing material (Times)Polyamide PA non-reinforced
Mounting position (Times)On horizontal DIN rail
Category (Connection data)1 (1-channel parameterization)
Output fuse (Power supply)6 A (gL / gG)
Stripping length (General)7 mm
Connection method (General)Screw connection
Contact type (Power supply)4 relay output contacts
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Degree of protection (Times)IP20
Designation (Connection data)EN 50156
Maximum altitude (Dimensions)max. 2000 m (See Appendix "Using PSR-TRISAFE modules at altitudes greater than 2000 m above sea level")
Recovery time (Alarm outputs)< 10 s
Response time (Alarm outputs)max. 50 ms
Status display (Power supply)4 x green LEDs
Nominal operating mode (Times)100% operating factor
Contact material (Power supply)AgSnO2(From HW03)AgCuNi + 0.2 - 0.4 μm Au (up to HW02)
Stop category (Connection data)0
Number of outputs (Power supply)4 (Single-channel)
Switching current (Power supply)min. 3 mA (from HW 03)
Switching voltage (Power supply)min. 12 V AC/DC (from HW 03)
Output description (Power supply)Relay contacts, safety-related N/O contacts
Switching capacity (Power supply)min. 60 mW
Status display (Ambient conditions)1 x green LED, 1 x red LED
Weight per Piece (excluding packing)220.000 g
(Safety-related characteristic data)10g (Δt = 16 ms, continuous shock, 1000 shocks in each space direction)
Air pressure (operation) (Dimensions)70 kPa ... 108 kPa (up to 3000 m above sea level)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Mechanical service life (Power supply)10x 106cycles
Protective circuit (Ambient conditions)Yes, within the scope of the operating voltage limits
Performance level (PL) (Connection data)c (1-channel parameterization)
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Limiting continuous current (Power supply)4 A (see to derating)
Ambient temperature (operation) (Dimensions)-20 °C ... 55 °C (see to derating)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Air pressure (storage/transport) (Dimensions)66 kPa ... 108 kPa (up to 3500 m above sea level)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Safety Integrity Level (SIL) (Connection data)max. 3 (Reference IEC 61508)
Voltage (Relay outputs: enabling current path)24 V DC (Supply via A1/A2)
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Min. degree of protection of inst. location (Times)IP54
Ambient temperature (storage/transport) (Dimensions)-20 °C ... 70 °C
Rated control supply current IS (Ambient conditions)Electrical supply via PSR-TBUS
Shock (operation) (Safety-related characteristic data)10g (Δt = 11 ms, three shocks in each space direction)
Degree of pollution (Safety-related characteristic data)2
Number of outputs (Relay outputs: enabling current path)4
Output description (Relay outputs: enabling current path)Digital
Overvoltage category (Safety-related characteristic data)III
Type of protection (Relay outputs: enabling current path)Yes, within the scope of the operating voltage limits
Max. permissible humidity (storage/transport) (Dimensions)75 % (On average, 85 % occasionally)
Standards/regulations (Safety-related characteristic data)DIN EN 50178
Vibration (operation) (Safety-related characteristic data)2g
Max. permissible relative humidity (operation) (Dimensions)75 % (On average, 85 % occasionally)
Rated control circuit supply voltage US (Ambient conditions)24 V DC (Electrical supply via PSR-TBUS)
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)1 (1-channel parameterization)
Short-circuit protection (Relay outputs: enabling current path)Yes
Limiting continuous current (Relay outputs: enabling current path)50 mA
Rated surge voltage/insulation (Safety-related characteristic data)4 kV / basic insulation between output contact current paths (13/14, 23/24, 33/34, 43/44); 6 kV / safe isolation, reinforced insulation between output contact current paths (13/14, 23/24, 33/34, 43/44) and the other circuits

Product Description

Relay output expansion module of the PSR-TRISAFE-M with 4 safe relay output contacts (optionally 4 single-channel relay contacts or 2 two-channel relay contacts), 4 salt. of notice; up to SIL 3, cat.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top