Technical Specifications

ParameterValue
GTIN4046356729246
NoteMade to Order (non-returnable)
Orderkey2903260
Catalog pagePage 266 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
(Input data)4 A gL/gG NEOZED (for low-demand applications)
Height (Note)112.2 mm
Country of originDE (Germany)
(Connection data)3
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)min. 7.5 ms (Test pulse rate; for all equivalent inputs)
Screw thread (General)M3
Net weight (Output data)99.99 g
Output fuse (Input data)6 A gL/gG NEOZED (N/O contact)
Relay type (Output data)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
Contact type (Input data)4 enabling current paths
Category (Connection data)4
Stripping length (General)7 mm
Connection method (General)Screw connection
Housing color (Output data)yellow
Mounting type (Output data)DIN rail mounting
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Input data)AgCuNi, +0.2 -0.4 µm Au
Designation (Connection data)EN 50156
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Sq. Total current (Input data)72 A2(ITH2= I12+ I22+ I32+ I42)
Mounting position (Output data)vertical or horizontal
Stop category (Connection data)0
Filter time (Ambient conditions)max. 1.5 ms (Test pulse duration; for all equivalent inputs)
Degree of protection (Output data)IP20
Recovery time (Ambient conditions)1 s (Availability time after activation of sensor circuit: 100ms)
Assembly instructions (Output data)See derating curve
Maximum inrush current (Input data)6 A
Status display (Ambient conditions)5 green LEDs
Inrush current, minimum (Input data)10 mA
Mechanical service life (Input data)10x 106cycles
Nominal operating mode (Output data)100% operating factor
Switching capacity min. (Input data)0.1 W
Weight per Piece (excluding packing)99.990 g
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Maximum switching voltage (Input data)250 V AC/DC
Minimum switching voltage (Input data)10 V AC/DC
Protective circuit (Ambient conditions)Surge protection Suppressor diode
Current consumption (Ambient conditions)typ. 5 mA (Imax/Ixinputs)
Limiting continuous current (Input data)6 A (N/O contact)
Performance level (PL) (Connection data)e (5 A DC13; 3 A AC15; 8760 cycles/year)
Typical release time (Ambient conditions)25 ms (when controlled via S11/S12 and S21/S22)
Concurrence input 1/2 (Ambient conditions)
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Typical response time (Ambient conditions)175 ms (monitored/manual start)
Ambient temperature (operation) (Dimensions)-20 °C ... 45 °C (see derating curve)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Nominal input voltage UN (Ambient conditions)24 V DC
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Operating voltage display (Ambient conditions)1 x green LED
Safety Integrity Level (SIL) (Connection data)3
Switching capacity (360/h cycles) (Input data)5 A (0,1 Hz; DC13; 24 V)
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Typ. starting time with Us (Ambient conditions)250 ms (when controlled via A1)
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Maximum switching frequency (Ambient conditions)0.5 Hz
Typical input current at UN (Ambient conditions)125 mA (with actuated relays)
Interrupting rating (ohmic load) max. (Input data)1500 VA (250 V AC, τ = 0 ms)
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 85 °C
Degree of pollution (Safety-related characteristic data)2
Maximum interrupting rating (inductive load) (Input data)48 W (24 V DC, τ = 40 ms)
Min. degree of protection of inst. location (Output data)IP54
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178/VDE 0160
Input voltage range in reference to UN (Ambient conditions)0.85 ... 1.1
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3
Voltage at input/start and feedback circuit (Ambient conditions)24 V -15 %; +10 % (first channel: 24 V; second channel: 0 V)
Max. permissible overall conductor resistance (Ambient conditions)100 Ω
Rated surge voltage/insulation (Safety-related characteristic data)4 kV/basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit, enabling current paths and safety circuit 1 (13/14, 23/24) and safety circuit 2 (43/44, 53/54).)

Product Description

Multifunctional safety relay for emergency stop, protection doors and light grids up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 NO contacts, 3 safety functions, 2 discon
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top