Service time: Monday to Friday 9:00-18:00
PSR-SCP- 24DC/ESD/5X1/1X2/ T 2 - PSR-SCP- 24DC/ESD/5X1/1X2/ T 2 2981125 PHOENIX CONTACT Safety relay for emergency stop and safety door monit..
In Stock Hot Product

PSR-SCP- 24DC/ESD/5X1/1X2/ T 2

PSR-SCP- 24DC/ESD/5X1/1X2/ T 2 2981125 PHOENIX CONTACT Safety relay for emergency stop and safety door monit..

$0.00USD
3471 in stock
Key Specifications
:< 40 mA (with Us/Ixto S12)
Depth:114.5 mm
Shock:15g
Width:45 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
< 40 mA (with Us/Ixto S12)
Depth114.5 mm
Shock15g
Width45 mm
Height99 mm
Controlone and two channel
pluggableYes
Net weight450.6 g
Relay typeElectromechanical relay with forcibly guided contacts in accordance with EN 50205
Filter time1 ms (at A1 in the event of voltage dips at Us)
Output fuse6 A gL/gG (N/C contact)
Contact type3 enabling current paths undelayed
Screw threadM3
Mounting typeDIN rail mounting
Recovery time< 1 s
Stop category0 (For non-delayed contacts)
Status display4 x green LEDs
Contact materialAgSnO2
Housing materialPBT
Maximum altitude≤ 2000 m (Above sea level)
Stripping length7 mm
Connection methodScrew connection
Mounting positionany
Sq. Total current55 A2(see to derating)
Current consumption< 40 mA (with Us/Ixto S10)
Degree of protectionIP54
Typical pick-up time< 600 ms (when controlled via A1)
Typical release time< 20 ms (with Us / when controlled via S11/S12 and S21/S22(K1/K2))
Concurrence input 1/2
Typical response time< 70 ms (Monitored/manual start)
Vibration (operation)10 Hz ...150 Hz, 2g
Maximum inrush current6 A
Typical inrush current200 mA
Inrush current, minimum25 mA
Mechanical service lifeApprox. 107cycles
Power consumption at UStyp. 3.6 W
Switching capacity min.0.4 W
Parameters for IEC 615083
Maximum switching voltage250 V AC/DC
Minimum switching voltage15 V AC/DC
Limiting continuous current6 A (N/O contact)
Maximum switching frequency0.5 Hz
Parameters as per EN ISO 138494 (undelayed contacts)
Ambient temperature (operation)-20 °C ... 55 °C (observe derating)
Rated control supply current IStyp. 150 mA
Conductor cross section AWG max.12
Conductor cross section AWG min.24
Conductor cross section solid max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Interrupting rating (ohmic load) max.144 W (24 V DC, τ = 0 ms)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Rated control circuit supply voltage US24 V DC -15 % / +10 %
Min. degree of protection of inst. locationIP54
Voltage at input/start and feedback circuitapprox. 23 V DC
Maximum interrupting rating (inductive load)42 W (24 V DC, τ = 40 ms)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistanceapprox. 11 Ω (Input and start circuits at UN)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top