| Parameter | Value |
|---|---|
| GTIN | 4046356912884 |
| Orderkey | 2700398 |
| Catalog page | Page 283 (C-6-2017) |
| Depth (Note) | 102.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 6.8 mm |
| Height (Note) | 93.1 mm |
| Torque (General) | 0.5 Nm ... 0.6 Nm |
| (Digital inputs) | 4 A gL/gG (for low-demand applications) |
| Country of origin | DE (Germany) |
| Indication (Times) | 1 x red LED |
| Net weight (Times) | 123.9 g |
| Relay type (Times) | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
| pluggable (General) | no |
| Custom tariff number | 85364900 |
| (Ambient conditions) | ≥ 100 ms (at A1-A2; test pulse rate) |
| Housing color (Times) | yellow |
| Mounting type (Times) | DIN rail mounting |
| Screw thread (General) | M3 |
| Status display (Times) | 2 x green LEDs |
| Housing material (Times) | PBT |
| Input name (Power supply) | Start circuit |
| Mounting position (Times) | vertical, horizontal, with front of module upward |
| Stripping length (General) | 12 mm |
| Connection method (General) | Screw connection |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Degree of protection (Times) | IP20 |
| Output fuse (Digital inputs) | 6 A gL/gG |
| Output name (Digital inputs) | Enabling current path |
| Assembly instructions (Times) | See derating curve |
| Contact type (Digital inputs) | 1 enabling current path |
| Designation (Connection data) | EN 50156 |
| Inrush current (Power supply) | < 10 mA |
| Maximum altitude (Dimensions) | ≤ 2000 m (Above sea level) |
| Recovery time (Alarm outputs) | 500 ms |
| Nominal operating mode (Times) | 100% operating factor |
| Inrush current (Digital inputs) | min. 3 mA |
| Number of inputs (Power supply) | 2 (Non-safety-related start inputs: Y1/Y2) |
| Stop category (Connection data) | 0 |
| Filter time (Ambient conditions) | max. 2 ms (at A1-A2; test pulse width) |
| Contact material (Digital inputs) | AgSnO2 |
| Operating voltage display (Times) | 1 x yellow LED |
| Current consumption (Power supply) | < 5 mA |
| Number of outputs (Digital inputs) | 1 (safety-related N/O contacts: 13/14) |
| Sq. Total current (Digital inputs) | 36 A2(observe derating) |
| Switching voltage (Digital inputs) | min. 12 V AC/DC |
| Inrush current (Ambient conditions) | typ. 400 mA (Δt s) |
| Output description (Digital inputs) | 2 N/O contacts in series, without delay, floating |
| Switching capacity (Digital inputs) | min. 60 mW |
| Switching frequency (Digital inputs) | max. 0.5 Hz |
| Weight per Piece (excluding packing) | 123.900 g |
| (Safety-related characteristic data) | Class I, Div. 2, Groups A, B, C, D, T4 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| GL (Safety-related characteristic data) | C, EMC2 |
| Protective circuit (Ambient conditions) | Serial protection against polarity reversal 33 V suppressor diode |
| Mechanical service life (Digital inputs) | 10x 106cycles |
| Typical pickup time at US (Alarm outputs) | < 200 ms (when controlled via A1, automatic start) |
| Conductor cross section AWG max. (General) | 12 |
| Conductor cross section AWG min. (General) | 26 |
| Shock (Safety-related characteristic data) | 15g |
| Typical release time at US (Alarm outputs) | < 35 ms (when controlled via A1) |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 70 °C (observe derating) |
| Conductor cross section solid max. (General) | 2.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Limiting continuous current (Digital inputs) | 6 A (High demand) |
| Power consumption at US (Ambient conditions) | typ. 1.2 W |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Current (Relay outputs: enabling current path) | max. 100 mA |
| Safety Integrity Level (SIL) (Connection data) | 3 |
| Voltage (Relay outputs: enabling current path) | approx. 22 V DC (Us- 2 V) |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Conformance (Safety-related characteristic data) | CE-compliant |
| Designation (Safety-related characteristic data) | Air clearances and creepage distances between the power circuits |
| Output fuse (Relay outputs: enabling current path) | 150 mA fast blow |
| Min. degree of protection of inst. location (Times) | IP54 |
| UL, USA/Canada (Safety-related characteristic data) | cULus |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Rated control supply current IS (Ambient conditions) | typ. 50 mA (depending on load M1 +100 mA) |
| Degree of pollution (Safety-related characteristic data) | 2 |
| Number of outputs (Relay outputs: enabling current path) | 1 (non-safety-related) |
| Output description (Relay outputs: enabling current path) | PNP |
| Overvoltage category (Safety-related characteristic data) | III |
| Max. permissible humidity (storage/transport) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Standards/regulations (Safety-related characteristic data) | DIN EN 50178, EN 60079-15 |
| Vibration (operation) (Safety-related characteristic data) | 10 Hz ...150 Hz, 2g |
| Voltage at input/start and feedback circuit (Power supply) | 24 V DC -15 % / +10 % |
| Max. permissible relative humidity (operation) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible overall conductor resistance (Power supply) | 150 Ω |
| Rated control circuit supply voltage US (Ambient conditions) | 24 V DC -15 % / +10 % (A1/A2) |
| Maximum inrush current (Relay outputs: enabling current path) | 500 mA (Δt = 1 ms at Us) |
| Rated insulation voltage (Safety-related characteristic data) | 250 V AC |
| Switching capacity according to IEC 60947-5-1 (Digital inputs) | 4 A (24 V (DC13)) |
| Short-circuit protection (Relay outputs: enabling current path) | no |
| Environmental simulation test (Safety-related characteristic data) | ISA-S71.04 (G3) |
| Rated surge voltage/insulation (Safety-related characteristic data) | Safe isolation, reinforced insulation 6 kV from control circuit, start circuit, signal output to the enabling current path; 4 kV / basic insulation between all current paths and housing |
Technical specifications and performance data
Installation and operation guide