| Parameter | Value |
|---|---|
| GTIN | 4046356729802 |
| Orderkey | 2903256 |
| Catalog page | Page 267 (C-6-2017) |
| Depth (Note) | 114.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 22.5 mm |
| (Input data) | 4 A gL/gG NEOZED (for low-demand applications) |
| Height (Note) | 106.4 mm |
| Country of origin | DE (Germany) |
| (Connection data) | 3 |
| pluggable (General) | no |
| Custom tariff number | 85371098 |
| (Ambient conditions) | min. 7.5 ms (Test pulse rate; for all equivalent inputs) |
| Net weight (Output data) | 204.9 g |
| Output fuse (Input data) | 6 A gL/gG NEOZED (N/O contact) |
| Relay type (Output data) | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
| Contact type (Input data) | 4 enabling current paths |
| Category (Connection data) | 4 |
| Stripping length (General) | 10 mm |
| Connection method (General) | Push-in connection |
| Housing color (Output data) | yellow |
| Mounting type (Output data) | DIN rail mounting |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Contact material (Input data) | AgCuNi, +0.2 -0.4 µm Au |
| Designation (Connection data) | EN 50156 |
| Maximum altitude (Dimensions) | ≤ 2000 m (Above sea level) |
| Sq. Total current (Input data) | 72 A2(ITH2= I12+ I22+ I32+ I42) |
| Mounting position (Output data) | vertical or horizontal |
| Stop category (Connection data) | 0 |
| Filter time (Ambient conditions) | max. 1.5 ms (Test pulse duration; for all equivalent inputs) |
| Degree of protection (Output data) | IP20 |
| Recovery time (Ambient conditions) | 1 s (Availability time after activation of sensor circuit: 100ms) |
| Assembly instructions (Output data) | See derating curve |
| Maximum inrush current (Input data) | 6 A |
| Status display (Ambient conditions) | 5 green LEDs |
| Inrush current, minimum (Input data) | 10 mA |
| Mechanical service life (Input data) | 10x 106cycles |
| Nominal operating mode (Output data) | 100% operating factor |
| Switching capacity min. (Input data) | 0.1 W |
| Weight per Piece (excluding packing) | 204.900 g |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Maximum switching voltage (Input data) | 250 V AC/DC |
| Minimum switching voltage (Input data) | 10 V AC/DC |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Protective circuit (Ambient conditions) | Surge protection Suppressor diode |
| Current consumption (Ambient conditions) | typ. 5 mA (Imax/Ixinputs) |
| Limiting continuous current (Input data) | 6 A (N/O contact) |
| Performance level (PL) (Connection data) | e (5 A DC13; 3 A AC15; 8760 cycles/year) |
| Typical release time (Ambient conditions) | 25 ms (when controlled via S11/S12 and S21/S22) |
| Concurrence input 1/2 (Ambient conditions) | ∞ |
| Conductor cross section AWG max. (General) | 12 |
| Conductor cross section AWG min. (General) | 24 |
| Typical response time (Ambient conditions) | 175 ms (monitored/manual start) |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 45 °C (see derating curve) |
| Conductor cross section solid max. (General) | 2.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Operating voltage display (Ambient conditions) | 1 x green LED |
| Safety Integrity Level (SIL) (Connection data) | 3 |
| Switching capacity (360/h cycles) (Input data) | 5 A (0,1 Hz; DC13; 24 V) |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Typ. starting time with Us (Ambient conditions) | 250 ms (when controlled via A1) |
| Designation (Safety-related characteristic data) | Air clearances and creepage distances between the power circuits |
| Maximum switching frequency (Ambient conditions) | 0.5 Hz |
| Typical input current at UN (Ambient conditions) | 125 mA (with actuated relays) |
| Interrupting rating (ohmic load) max. (Input data) | 1500 VA (250 V AC, τ = 0 ms) |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Degree of pollution (Safety-related characteristic data) | 2 |
| Maximum interrupting rating (inductive load) (Input data) | 48 W (24 V DC, τ = 40 ms) |
| Min. degree of protection of inst. location (Output data) | IP54 |
| Overvoltage category (Safety-related characteristic data) | III |
| Max. permissible humidity (storage/transport) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Standards/regulations (Safety-related characteristic data) | DIN EN 50178/VDE 0160 |
| Input voltage range in reference to UN (Ambient conditions) | 0.85 ... 1.1 |
| Max. permissible relative humidity (operation) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Rated control circuit supply voltage US (Ambient conditions) | |
| Rated insulation voltage (Safety-related characteristic data) | 250 V AC |
| Safety Integrity Level Claim Limit (SIL CL) (Connection data) | 3 |
| Voltage at input/start and feedback circuit (Ambient conditions) | 24 V -15 %; +10 % (first channel: 24 V; second channel: 0 V) |
| Max. permissible overall conductor resistance (Ambient conditions) | 100 Ω |
| Rated surge voltage/insulation (Safety-related characteristic data) | 4 kV/basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit, enabling current paths and safety circuit 1 (13/14, 23/24) and safety circuit 2 (43/44, 53/54).) |