Key Specifications
GTIN:4055626133201
Orderkey:2702355
Catalog page:Page 276 (C-6-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626133201
Orderkey2702355
Catalog pagePage 276 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
Height (Note)112.2 mm
Country of originDE (Germany)
Net weight (Times)150.1 g
(Measuring inputs)max. 5 A
pluggable (General)Yes
Custom tariff number85389091
(Ambient conditions)Protection against polarity reversal for rated control circuit supply voltage
Housing color (Times)yellow
Mounting type (Times)DIN rail mounting
Screw thread (General)M3
Status display (Times)4 x LED Bi-Colour
Housing material (Times)PBT
Mounting position (Times)vertical or horizontal
Category (Connection data)3
Stripping length (General)7 mm
Connection method (General)Screw connection
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Degree of protection (Times)IP20
Assembly instructions (Times)See derating curve
Designation (Connection data)EN 62061
Maximum altitude (Dimensions)max. 2000 m (Above sea level)
Response time (Alarm outputs)typ. 20 ms (at 50 Hz input frequency)
Limit frequency (Power supply)max. 3 kHz (At voltages > 2 VRMS)
Nominal operating mode (Times)100% operating factor
Output fuse (Measuring inputs)5 A gL/gG
Output name (Measuring inputs)Enabling current path
Contact type (Measuring inputs)1 enabling current path
Stop category (Connection data)0
Delay time range (Alarm outputs)0.5 s ... 20 s ±1 % (K1, K2 can be parameterized)
Filter time (Ambient conditions)1 ms (at A1 in the event of voltage dips at Us)
Inrush current (Measuring inputs)min. 3 mA
Current consumption (Power supply)max. 0.35 mA (at L1/L2/L3)
Contact material (Measuring inputs)AgSnO2
Inrush current (Ambient conditions)5.6 A (Δt = 400 µs at Us)
Voltage input signal (Power supply)max. 690 V AC/DC (at L1/L2/L3)
Number of outputs (Measuring inputs)1 (undelayed)
Sq. Total current (Measuring inputs)25 A2(observe derating)
Switching voltage (Measuring inputs)min. 24 V AC/DC
Weight per Piece (excluding packing)150.100 g
(Safety-related characteristic data)Safe isolation, reinforced insulation 6 kV:between A1/A2 and 13/14between MO/FO and 13/14Safe isolation, reinforced insulation 8 kV:between L1/L2/L3 and A1/A2between L1/L2/L3 and MO/FObetween L1/L2/L3 and 13/14
Output description (Measuring inputs)safety-related N/O contacts
Switching capacity (Measuring inputs)min. 72 mW
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Switching frequency (Measuring inputs)max. 0.5 Hz
Protective circuit (Ambient conditions)Surge protection Suppressor diode
Performance level (PL) (Connection data)e (4 A DC13; 5 A AC15; 17520 switching cycles/year)
Typical pickup time at US (Alarm outputs)< 1 s
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Mechanical service life (Measuring inputs)10x 106cycles
Shock (Safety-related characteristic data)15g
Ambient temperature (operation) (Dimensions)-20 °C ... 55 °C (observe derating)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Power consumption at US (Ambient conditions)typ. 1.2 W
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Current (Relay outputs: enabling current path)max. 100 mA
Limiting continuous current (Measuring inputs)5 A (observe derating)
Safety Integrity Level (SIL) (Connection data)3 (4 A DC13; 5 A AC15; 17520 switching cycles/year)
Voltage (Relay outputs: enabling current path)23 V DC (US- 1 V)
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Conformance (Safety-related characteristic data)CE-compliant
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Min. degree of protection of inst. location (Times)IP54
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Rated control supply current IS (Ambient conditions)typ. 50 mA
Degree of pollution (Safety-related characteristic data)2
Number of outputs (Relay outputs: enabling current path)2 (digital, PNP)
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178
Vibration (operation) (Safety-related characteristic data)10 Hz ...150 Hz, 2g
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)24 V DC -15 % / +10 %
Maximum inrush current (Relay outputs: enabling current path)500 mA
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3 (4 A DC13; 5 A AC15; 17520 switching cycles/year)
Short-circuit protection (Relay outputs: enabling current path)Yes
Rated surge voltage/insulation (Safety-related characteristic data)Basic insulation 4 kV:between all current paths and housingBasic insulation 8 kV:between L1 and L2between L1 and L3between L2 and L3

Product Description

Safety switching device for sensorless stop control in three-phase and single-phase motors up to SIL 3, category 3, PL e, two-channel evaluation of the recall voltage of alternating, three-phase and d
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top