Key Specifications
GTIN:4055626496566
Orderkey:1015526
(Drawings):
Catalog page:Page 227 (C-6-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626496566
Orderkey1015526
(Drawings)
Catalog pagePage 227 (C-6-2019)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
Height (Note)117.5 mm
(Power supply)max. 1 Hz
(Alarm outputs)non-safety-related
(Clock outputs)< 5 ms (when controlled via A1; applicative deactivation via A1/A2 is not permitted)
(Digital inputs)4 A gL/gG (for low-demand applications)
Country of originDE (Germany)
ETIM 5.0 (eCl@ss)EC001449
ETIM 6.0 (eCl@ss)EC001449
ETIM 7.0 (eCl@ss)EC001449
Net weight (Times)155.43 g
Relay type (Times)Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205)
pluggable (General)Yes
Custom tariff number85371098
Housing color (Times)yellow
Mounting type (Times)DIN rail mounting
(Connection capacity)1
Status display (Times)5 x bi-color LED
Current (Alarm outputs)max. 100 mA
Voltage (Alarm outputs)corresponds to US
Block diagram (Drawings)
Housing material (Times)PBT
Input name (Power supply)Start circuit
Mounting position (Times)vertical or horizontal
Filter time (Power supply)max. 3 ms (Test pulse width of low test pulses)
Stripping length (General)8 mm
Connection method (General)Push-in spring connection
Designation (Alarm outputs)S11, S21
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Cable length (Alarm outputs)max. 150 m
Degree of protection (Times)IP20
Output fuse (Digital inputs)6 A gL/gG
Output name (Digital inputs)Enabling current paths
Restart time (Clock outputs)< 1 s (Boot time)
eCl@ss 8.0 (Classifications)27371819
eCl@ss 9.0 (Classifications)27371819
Assembly instructions (Times)See derating curve
Contact type (Digital inputs)5 enabling current paths
Inrush current (Power supply)< 8.6 mA (typically with US)
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Recovery time (Clock outputs)500 ms (following demand of the safety function)
Category (Connection capacity)4
Limit frequency (Power supply)min. 0 Hz
Nominal operating mode (Times)100% operating factor
Inrush current (Digital inputs)min. 3 mA
Number of inputs (Power supply)1
Delay time range (Clock outputs)0.2 s ... 300 s ±5 % (can be set for 47/48/58)
Designation (Ambient conditions)A1/A2
Filter time (Ambient conditions)10 ms (For the logic. At A1 in the event of voltage dips at Us)
Contact material (Digital inputs)AgSnO2
Designation (Connection capacity)EN 62061
Number of outputs (Alarm outputs)2
Current consumption (Power supply)< 3.2 mA (typically with US)
Number of outputs (Digital inputs)3 (undelayed: 13/14, 23/24/34)
Output description (Alarm outputs)PNP
Sq. Total current (Digital inputs)108 A2(observe derating)
Switching voltage (Digital inputs)min. 12 V AC/DC
Utilization restriction (Drawings)EMC: class A product, see manufacturer's declaration in the download area
Inrush current (Ambient conditions)typ. 28 A (Δt = 30 µs at Us)
Output description (Digital inputs)2 N/O contacts each in series, safety-related, floating
Stop category (Connection capacity)0
Switching capacity (Digital inputs)min. 60 mW
Concurrence input 1/2 (Power supply)
Switching frequency (Digital inputs)0.5 Hz (depending on the set delay time)
Weight per Piece (excluding packing)0.000 g
(Safety-related characteristic data)Safe isolation, reinforced insulation 6 kV between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14) and enabling current path (23/24/34) and enabling current path (47/48/58)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Maximum inrush current (Alarm outputs)500 mA (Δt = 10 ms at Us)
REACh SVHC (Standards and Regulations)Lead 7439-92-1
(Relay outputs: enabling current path)non-safety-related
Conductor cross section solid (General)0.2 mm² ... 1.5 mm²
Description of the input (Power supply)non-safety-related
Protective circuit (Ambient conditions)Serial protection against polarity reversal Suppressor diode
Mechanical service life (Digital inputs)10x 106cycles
Short-circuit protection (Alarm outputs)Yes
Typical pickup time at US (Clock outputs)500 ms (with Uswhen controlled via A1)
Conductor cross section flexible (General)0.2 mm² ... 1.5 mm²
Shock (Safety-related characteristic data)10g (operation), 15g (transport)
Typical release time at US (Clock outputs)< 25 ms (when controlled via S12 and S22 (only for undelayed contacts))
Protective circuit/component (Power supply)Varistor
Typical response time at US (Clock outputs)< 40 ms (automatic start)
Ambient temperature (operation) (Dimensions)-35 °C ... 60 °C (observe derating)
Limiting continuous current (Digital inputs)6 A
Performance level (PL) (Connection capacity)e (4 A DC13; 5 A AC15; 8760 switching cycles/year)
Power consumption at US (Ambient conditions)typ. 1.92 W
Protective circuit/component (Alarm outputs)Suppressor diode
Conductor cross section AWG / kcmil (General)24 ... 16
Input current range "0" signal (Power supply)0 mA ... 2 mA
Input voltage range "0" signal (Power supply)0 V DC ... 5 V DC
Input voltage range "1" signal (Power supply)11 V DC ... 30 V DC
Current (Relay outputs: enabling current path)max. 100 mA
Voltage (Relay outputs: enabling current path)approx. 23 V DC (US- 1 V)
Conformance (Safety-related characteristic data)CE-compliant
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Designation (Relay outputs: enabling current path)M1
Safety Integrity Level (SIL) (Connection capacity)3
Min. degree of protection of inst. location (Times)IP54
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Rated control supply current IS (Ambient conditions)typ. 80 mA
Degree of pollution (Safety-related characteristic data)2
Number of outputs (Relay outputs: enabling current path)1
Output description (Relay outputs: enabling current path)PNP
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistance (Power supply)150 Ω
Rated control circuit supply voltage US (Ambient conditions)24 V DC -20 % / +25 %
Maximum inrush current (Relay outputs: enabling current path)500 mA (Δt = 10 ms at Us)
Rated insulation voltage (Safety-related characteristic data)250 V AC
Switching capacity according to IEC 60947-5-1 (Digital inputs)4 A (24 V (DC13))
Short-circuit protection (Relay outputs: enabling current path)Yes
Safety Integrity Level Claim Limit (SIL CL) (Connection capacity)3
Protective circuit/component (Relay outputs: enabling current path)Suppressor diode
Rated surge voltage/insulation (Safety-related characteristic data)Basic insulation 4 kV between all current paths and housing
Conductor cross section, flexible, with ferrule, with plastic sleeve (General)0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve (General)0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Product Description

Safety relay for emergency stop, safety doors, light curtains up to SIL 3, category 4, PL e, 1 or 2 channel operation, transverse short circuit detection, reactivatable, return/excitation delay 0.2 s
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top