Key Specifications
GTIN:4046356952477
Orderkey:2702095
Catalog page:Page 258 (C-6-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356952477
Orderkey2702095
Catalog pagePage 258 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)12.5 mm
Height (Note)116.6 mm
(Power supply)Test pulse rate = 7 x Test pulse width
(Alarm outputs)< 5 ms (when interrupted via A1; applicative deactivation via A1/A2 is not permitted)
(Digital inputs)4 A gL/gG (for low-demand applications)
Country of originDE (Germany)
Net weight (Times)126.6 g
Relay type (Times)Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205)
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)Protection against polarity reversal for rated control circuit supply voltage
Housing color (Times)yellow
Mounting type (Times)DIN rail mounting
Status display (Times)5 x bi-color LED
Housing material (Times)PBT
Mounting position (Times)vertical or horizontal
Category (Connection data)1 (up to Cat. 3 depending on the application)
Filter time (Power supply)max. 3 ms (at S12, S22, S34; test pulse width)
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
(Standards and Regulations)No hazardous substances above threshold values
Degree of protection (Times)IP20
Output fuse (Digital inputs)6 A gL/gG (N/O contact)
Output name (Digital inputs)Enabling current path
Restart time (Alarm outputs)< 1 s (Boot time)
Assembly instructions (Times)See derating curve
Contact type (Digital inputs)2 enabling current paths
Designation (Connection data)EN 62061
Inrush current (Power supply)< 11 mA (with Us/Ixto S12/S22)
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Nominal operating mode (Times)100% operating factor
Inrush current (Digital inputs)min. 3 mA
Stop category (Connection data)1
Delay time range (Alarm outputs)0.2 s ... 60 s ±5 % (can be set for 27/28)
Filter time (Ambient conditions)10 ms (For the logic. At A1 in the event of voltage dips at Us)
Contact material (Digital inputs)AgSnO2
Current consumption (Power supply)< 4.1 mA (with Us/Ixto S12/S22)
Number of outputs (Digital inputs)1 (undelayed, single-channel)
Sq. Total current (Digital inputs)72 A2(observe derating)
Switching voltage (Digital inputs)min. 12 V AC/DC
Inrush current (Ambient conditions)typ. 25 A (Δt = 10 µs at Us)
Output description (Digital inputs)safety-related N/O contacts
Switching capacity (Digital inputs)min. 60 mW
Concurrence input 1/2 (Power supply)
Switching frequency (Digital inputs)1 Hz
Weight per Piece (excluding packing)126.600 g
(Safety-related characteristic data)250 V AC
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Protective circuit (Ambient conditions)Surge protection Suppressor diode
Mechanical service life (Digital inputs)10x 106cycles
Performance level (PL) (Connection data)c (up to PL e depending on the application)
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g
Typical release time at US (Alarm outputs)< 20 ms (when controlled via S12 (only for undelayed contact 13/14))
Typical response time at US (Alarm outputs)< 35 ms (automatic start)
Ambient temperature (operation) (Dimensions)-35 °C ... 60 °C (observe derating)
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Limiting continuous current (Digital inputs)6 A (observe derating)
Power consumption at US (Ambient conditions)typ. 1.2 W
Input current range "0" signal (Power supply)0 mA ... 2 mA (for safe Off)
Input voltage range "0" signal (Power supply)0 V DC ... 5 V DC (for safe Off)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Current (Relay outputs: enabling current path)max. 100 mA
Safety Integrity Level (SIL) (Connection data)1 (up to SIL 3 depending on the application)
Voltage (Relay outputs: enabling current path)23 V DC (US- 1 V)
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Conformance (Safety-related characteristic data)CE-compliant
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Min. degree of protection of inst. location (Times)IP54
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Rated control supply current IS (Ambient conditions)typ. 50 mA
Degree of pollution (Safety-related characteristic data)2
Number of outputs (Relay outputs: enabling current path)1 (digital, PNP)
Output description (Relay outputs: enabling current path)non-safety-related
Overvoltage category (Safety-related characteristic data)III
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178
Vibration (operation) (Safety-related characteristic data)10 Hz ...150 Hz, 2g
Voltage at input/start and feedback circuit (Power supply)24 V DC -20 % / +25 %
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistance (Power supply)150 Ω
Rated control circuit supply voltage US (Ambient conditions)24 V DC -20 % / +25 %
Maximum inrush current (Relay outputs: enabling current path)500 mA (Δt = 1 ms at Us)
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)1 (up to SILCL 3 depending on the application)
Short-circuit protection (Relay outputs: enabling current path)Yes
Rated surge voltage/insulation (Safety-related characteristic data)Basic insulation 4 kV: between all current paths and housingSafe isolation, reinforced insulation 6 kV:between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14)between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (27/28)between enabling current paths

Product Description

Safety relay for emergency stop, safety doors, light curtains up to SIL 1, category 1, PL c, 1 or 2 channel operation, transverse short circuit detection, reactivatable, return/excitation delay 0.2 s
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide