| Parameter | Value |
|---|---|
| < 5 ms (when interrupted via A1; applicative deactivation via A1/A2 is not permitted) | |
| Color | yellow |
| Depth | 114.5 mm |
| Shock | 15g |
| Width | 12.5 mm |
| Height | 116.6 mm |
| Current | max. 100 mA |
| Voltage | 22 V DC (Us- 2 V) |
| Category | 4 (4 A DC13; 5 A AC15; 8760 switching cycles/year) |
| pluggable | yes |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Type class | IIIC |
| Application | Two-hand control |
| Concurrence | |
| Designation | A1/A2 |
| Filter time | 10 ms (For the logic. At A1 in the event of voltage dips at Us) |
| Output fuse | 6 A gL/gG (N/O contact) |
| Product type | Safety relays |
| Restart time | < 2 s (Boot time) |
| Assembly note | See derating curve |
| Mounting type | DIN rail mounting |
| Recovery time | < 500 ms |
| Stop category | 0 |
| Identification | CE-compliant |
| Inrush current | typ. 20 A (Δt = 10 µs at Us) |
| Product family | PSRmini |
| Status display | 5 x bi-color LED |
| Article revision | 04 |
| Contact material | AgSnO2(enabling current path) |
| Housing material | Polyamide |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Number of inputs | 2 |
| Stripping length | 8 mm |
| Connection method | Push-in connection |
| Mounting position | vertical or horizontal |
| Number of outputs | 2 (undelayed) |
| Sq. Total current | 72 A2(observe derating) |
| Switching voltage | min. 12 V AC/DC |
| Output description | safety-related N/O contacts |
| Protective circuit | Surge protection; Suppressor diode |
| Switching capacity | min. 60 mW |
| Current consumption | < 4.2 mA (with Us/Ixto S12/S22) |
| Switching frequency | 0.1 Hz |
| Degree of protection | IP20 |
| Typical release time | < 10 ms (when controlled via S12/S22) |
| Standards/regulations | DIN EN 50178 |
| Typical response time | < 50 ms |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Contact switching type | 2 enabling current paths |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Nominal operating mode | 100% operating factor |
| Performance level (PL) | e (4 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Mechanical service life | 10x 106cycles |
| Power consumption at US | typ. 0.96 W |
| Description of the input | safety-related sensor inputs |
| Rated insulation voltage | 250 V AC |
| Short-circuit protection | Yes |
| Conductor cross-section AWG | 24 ... 16 |
| Limiting continuous current | 6 A |
| Safety Integrity Level (SIL) | 3 (4 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
| Ambient temperature (operation) | -35 °C ... 60 °C (observe derating) |
| Rated control supply current IS | typ. 40 mA |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Rated control circuit supply voltage US | 19.2 V DC ... 30 V DC |
| Min. degree of protection of inst. location | IP54 |
| Voltage at input/start and feedback circuit | 24 V DC -20 % / +25 % |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible overall conductor resistance | 150 Ω |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum power dissipation for nominal condition | 5.09 W (at US= 30 V, IL² = 72 A²) |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
Technical specifications and performance data
Installation and operation guide