| Parameter | Value |
|---|---|
| GTIN | 4055626458564 |
| Orderkey | 2702902 |
| (Drawings) | |
| Catalog page | Page 224 (C-6-2019) |
| Depth (Note) | 114.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 17.5 mm |
| Height (Note) | 116.6 mm |
| (Alarm outputs) | < 20 ms (on demand via A1) |
| (Digital inputs) | max. 16 Byte (Output data) |
| (IO-Link inputs) | 4 A gL/gG (for low-demand applications) |
| Country of origin | DE (Germany) |
| ETIM 5.0 (eCl@ss) | EC001449 |
| ETIM 6.0 (eCl@ss) | EC001449 |
| ETIM 7.0 (eCl@ss) | EC001449 |
| Net weight (Times) | 150.98 g |
| Relay type (Times) | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
| pluggable (General) | Yes |
| Custom tariff number | 85371098 |
| Housing color (Times) | yellow |
| Mounting type (Times) | DIN rail mounting |
| Status display (Times) | 5x LED green |
| Block diagram (Drawings) | |
| Housing material (Times) | PBT |
| Mounting position (Times) | vertical or horizontal |
| Designation (Power supply) | L+/L- |
| Port type (Digital inputs) | Class A |
| Stripping length (General) | 8 mm |
| Connection method (General) | Push-in spring connection |
| Cycle Time (Digital inputs) | 5 ms |
| Input name (Digital inputs) | C/Q |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Degree of protection (Times) | IP20 |
| Designation (Digital inputs) | IO-Link |
| Output fuse (IO-Link inputs) | 6 A gL/gG |
| Output name (IO-Link inputs) | Enabling current path |
| Restart time (Alarm outputs) | < 1 s (Boot time) |
| eCl@ss 5.1 (Classifications) | 27371901 |
| eCl@ss 6.0 (Classifications) | 27371819 |
| eCl@ss 8.0 (Classifications) | 27371819 |
| eCl@ss 9.0 (Classifications) | 27371819 |
| Assembly instructions (Times) | See derating curve |
| Contact type (IO-Link inputs) | 2 enabling current paths |
| Maximum altitude (Dimensions) | ≤ 2000 m (Above sea level) |
| Recovery time (Alarm outputs) | < 500 ms |
| (Supply of the IO-Link ports) | > -5 mA (typically with USat S34/0 V) |
| Category (Connection capacity) | 4 |
| Nominal operating mode (Times) | 100% operating factor |
| Specification (Digital inputs) | Version 1.1 |
| Inrush current (IO-Link inputs) | min. 3 mA |
| Designation (Ambient conditions) | A1/A2 |
| Filter time (Ambient conditions) | 1 ms (at A1 in the event of voltage dips at Us) |
| Number of ports (Digital inputs) | 1 |
| Contact material (IO-Link inputs) | AgSnO2 |
| Designation (Connection capacity) | EN 62061 |
| Number of inputs (Digital inputs) | 1 |
| Operating voltage display (Times) | 1 x green, yellow, red LED |
| Type of protection (Power supply) | Serial protection against polarity reversal |
| Connection method (Digital inputs) | Spring-cage connection |
| Current consumption (Power supply) | typ. 16 mA |
| Number of outputs (IO-Link inputs) | 2 (undelayed) |
| Sq. Total current (IO-Link inputs) | 72 A2(observe derating) |
| Switching voltage (IO-Link inputs) | min. 12 V AC/DC |
| Utilization restriction (Drawings) | EMC: class A product, see manufacturer's declaration in the download area |
| Inrush current (Ambient conditions) | typ. 2.5 A (Δt = 500 µs at Us) |
| Output description (IO-Link inputs) | safety-related N/O contacts |
| Stop category (Connection capacity) | 0 |
| Switching capacity (IO-Link inputs) | min. 60 mW |
| Transmission speed (Digital inputs) | 230 kbps (COM3) |
| Process data update (Digital inputs) | 5 ms |
| Switching frequency (IO-Link inputs) | 0.5 Hz |
| Weight per Piece (excluding packing) | 180.000 g |
| (Safety-related characteristic data) | Safe isolation, reinforced insulation 4 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Connection technology (Digital inputs) | 3-wire |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| (Relay outputs: enabling current path) | non-safety-related |
| Amount of process data (Digital inputs) | max. 31 Byte (Input data) |
| Conductor cross section solid (General) | 0.2 mm² ... 1.5 mm² |
| Protective circuit (Ambient conditions) | Serial protection against polarity reversal Suppressor diode |
| Input name (Supply of the IO-Link ports) | Start circuit |
| Mechanical service life (IO-Link inputs) | 10x 106cycles |
| Description of the input (Digital inputs) | IO-Link switching and communication cable |
| Filter time (Supply of the IO-Link ports) | max. 1.5 ms (Test pulse width of low test pulses) |
| Typical pickup time at US (Alarm outputs) | < 250 ms (when controlled via A1) |
| Conductor cross section flexible (General) | 0.2 mm² ... 1.5 mm² |
| Shock (Safety-related characteristic data) | 15g |
| Typical release time at US (Alarm outputs) | < 20 ms (on demand via the sensor circuit) |
| Protective circuit/component (Power supply) | Suppressor diode |
| Typical response time at US (Alarm outputs) | < 220 ms (automatic start) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 60 °C (observe derating) |
| Inrush current (Supply of the IO-Link ports) | < 10 mA (typically with US, Δt = 100 ms) |
| Limiting continuous current (IO-Link inputs) | 6 A |
| Performance level (PL) (Connection capacity) | e (4 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Power consumption at US (Ambient conditions) | typ. 1.44 W |
| Conductor cross section AWG / kcmil (General) | 24 ... 16 |
| Nominal voltage for I/O supply (Power supply) | 24 V DC -20 % / +25 % (is provided via the IO-Link interface of the IO-Link master.) |
| Current (Relay outputs: enabling current path) | max. 100 mA |
| Number of inputs (Supply of the IO-Link ports) | 1 |
| Voltage (Relay outputs: enabling current path) | approx. 22 V DC (Us- 2 V) |
| Conformance (Safety-related characteristic data) | CE-compliant |
| Designation (Safety-related characteristic data) | Air clearances and creepage distances between the power circuits |
| Current consumption (Supply of the IO-Link ports) | < 5 mA (typically with USat S34/24 V) |
| Input voltage range (Supply of the IO-Link ports) | 0 V DC ... 30 V DC |
| Designation (Relay outputs: enabling current path) | M1 |
| Safety Integrity Level (SIL) (Connection capacity) | 3 |
| Concurrence input 1/2 (Supply of the IO-Link ports) | ∞ |
| Min. degree of protection of inst. location (Times) | IP54 |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Rated control supply current IS (Ambient conditions) | typ. 60 mA |
| Description of the input (Supply of the IO-Link ports) | NPN (manual start), PNP (autostart) |
| Degree of pollution (Safety-related characteristic data) | 2 |
| Number of outputs (Relay outputs: enabling current path) | 1 |
| Output description (Relay outputs: enabling current path) | PNP |
| Overvoltage category (Safety-related characteristic data) | II |
| Max. permissible humidity (storage/transport) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Protective circuit/component (Supply of the IO-Link ports) | Suppressor diode |
| Standards/regulations (Safety-related characteristic data) | DIN EN 60947-1 |
| Vibration (operation) (Safety-related characteristic data) | 10 Hz ... 150 Hz, 2g |
| Max. permissible relative humidity (operation) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Input current range "0" signal (Supply of the IO-Link ports) | 0 mA ... 2 mA |
| Input voltage range "0" signal (Supply of the IO-Link ports) | 0 V DC ... 5 V DC |
| Input voltage range "1" signal (Supply of the IO-Link ports) | 19.2 V DC ... 30 V DC (manual start, autostart: 0 V) |
| Rated control circuit supply voltage US (Ambient conditions) | 24 V DC -20 % / +25 % (provide external protection) |
| Maximum inrush current (Relay outputs: enabling current path) | 500 mA (Δt = 1 ms at Us) |
| Rated insulation voltage (Safety-related characteristic data) | 320 V |
| Switching capacity according to IEC 60947-5-1 (IO-Link inputs) | 4 A (24 V (DC13)) |
| Safety Integrity Level Claim Limit (SIL CL) (Connection capacity) | 3 |
| Protective circuit/component (Relay outputs: enabling current path) | Suppressor diode |
| Rated surge voltage/insulation (Safety-related characteristic data) | Basic insulation 4 kV between all current paths and housing |
| Max. permissible overall conductor resistance (Supply of the IO-Link ports) | 150 Ω |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (General) | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross section flexible, with ferrule without plastic sleeve (General) | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
Technical specifications and performance data
Installation and operation guide