Service time: Monday to Friday 9:00-18:00
PSR-MC42-2NO-1DO-24DC-SC - PSR-MC42-2NO-1DO-24DC-SC 2702901 PHOENIX CONTACT Safety relay with IO-Link for emergency stop, safety doors,..
In Stock Hot Product

PSR-MC42-2NO-1DO-24DC-SC

PSR-MC42-2NO-1DO-24DC-SC 2702901 PHOENIX CONTACT Safety relay with IO-Link for emergency stop, safety doors,..

$0.00USD
3122 in stock
Key Specifications
GTIN:4055626458540
Orderkey:2702901
(Drawings):
Catalog page:Page 224 (C-6-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626458540
Orderkey2702901
(Drawings)
Catalog pagePage 224 (C-6-2019)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)17.5 mm
Height (Note)112.2 mm
(Alarm outputs)< 20 ms (on demand via A1)
Torque (General)0.5 Nm ... 0.6 Nm
(Digital inputs)max. 16 Byte (Output data)
(IO-Link inputs)4 A gL/gG (for low-demand applications)
Country of originDE (Germany)
ETIM 5.0 (eCl@ss)EC001449
ETIM 6.0 (eCl@ss)EC001449
ETIM 7.0 (eCl@ss)EC001449
Net weight (Times)157.28 g
Relay type (Times)Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205)
pluggable (General)Yes
Custom tariff number85371098
Housing color (Times)yellow
Mounting type (Times)DIN rail mounting
Screw thread (General)M3
Status display (Times)5x LED green
Block diagram (Drawings)
Housing material (Times)PBT
Mounting position (Times)vertical or horizontal
Category (Connection data)4
Designation (Power supply)L+/L-
Port type (Digital inputs)Class A
Stripping length (General)7 mm
Connection method (General)Screw connection
Cycle Time (Digital inputs)5 ms
Input name (Digital inputs)C/Q
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Degree of protection (Times)IP20
Designation (Digital inputs)IO-Link
Output fuse (IO-Link inputs)6 A gL/gG
Output name (IO-Link inputs)Enabling current path
Restart time (Alarm outputs)< 1 s (Boot time)
eCl@ss 5.1 (Classifications)27371901
eCl@ss 6.0 (Classifications)27371819
eCl@ss 8.0 (Classifications)27371819
eCl@ss 9.0 (Classifications)27371819
Assembly instructions (Times)See derating curve
Contact type (IO-Link inputs)2 enabling current paths
Designation (Connection data)EN 62061
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Recovery time (Alarm outputs)< 500 ms
(Supply of the IO-Link ports)> -5 mA (typically with USat S34/0 V)
Nominal operating mode (Times)100% operating factor
Specification (Digital inputs)Version 1.1
Inrush current (IO-Link inputs)min. 3 mA
Stop category (Connection data)0
Designation (Ambient conditions)A1/A2
Filter time (Ambient conditions)1 ms (at A1 in the event of voltage dips at Us)
Number of ports (Digital inputs)1
Contact material (IO-Link inputs)AgSnO2
Number of inputs (Digital inputs)1
Operating voltage display (Times)1 x green, yellow, red LED
Type of protection (Power supply)Serial protection against polarity reversal
Connection method (Digital inputs)Screw connection
Current consumption (Power supply)typ. 16 mA
Number of outputs (IO-Link inputs)2 (undelayed)
Sq. Total current (IO-Link inputs)72 A2(observe derating)
Switching voltage (IO-Link inputs)min. 12 V AC/DC
Utilization restriction (Drawings)EMC: class A product, see manufacturer's declaration in the download area
Inrush current (Ambient conditions)typ. 2.5 A (Δt = 500 µs at Us)
Output description (IO-Link inputs)safety-related N/O contacts
Switching capacity (IO-Link inputs)min. 60 mW
Transmission speed (Digital inputs)230 kbps (COM3)
Process data update (Digital inputs)5 ms
Switching frequency (IO-Link inputs)0.5 Hz
Weight per Piece (excluding packing)180.000 g
(Safety-related characteristic data)Safe isolation, reinforced insulation 4 kV between input circuit and enabling current path (13/14) and enabling current path (23/24)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Connection technology (Digital inputs)3-wire
REACh SVHC (Standards and Regulations)Lead 7439-92-1
(Relay outputs: enabling current path)non-safety-related
Amount of process data (Digital inputs)max. 31 Byte (Input data)
Protective circuit (Ambient conditions)Serial protection against polarity reversal Suppressor diode
Input name (Supply of the IO-Link ports)Start circuit
Mechanical service life (IO-Link inputs)10x 106cycles
Performance level (PL) (Connection data)e (4 A DC13; 5 A AC15; 8760 switching cycles/year)
Description of the input (Digital inputs)IO-Link switching and communication cable
Filter time (Supply of the IO-Link ports)max. 1.5 ms (Test pulse width of low test pulses)
Typical pickup time at US (Alarm outputs)< 250 ms (when controlled via A1)
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g
Typical release time at US (Alarm outputs)< 20 ms (on demand via the sensor circuit)
Protective circuit/component (Power supply)Suppressor diode
Typical response time at US (Alarm outputs)< 220 ms (automatic start)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C (observe derating)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Inrush current (Supply of the IO-Link ports)< 10 mA (typically with US, Δt = 100 ms)
Limiting continuous current (IO-Link inputs)6 A
Power consumption at US (Ambient conditions)typ. 1.44 W
Nominal voltage for I/O supply (Power supply)24 V DC -20 % / +25 % (is provided via the IO-Link interface of the IO-Link master.)
Current (Relay outputs: enabling current path)max. 100 mA
Number of inputs (Supply of the IO-Link ports)1
Safety Integrity Level (SIL) (Connection data)3
Voltage (Relay outputs: enabling current path)approx. 22 V DC (Us- 2 V)
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Conformance (Safety-related characteristic data)CE-compliant
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Current consumption (Supply of the IO-Link ports)< 5 mA (typically with USat S34/24 V)
Input voltage range (Supply of the IO-Link ports)0 V DC ... 30 V DC
Designation (Relay outputs: enabling current path)M1
Concurrence input 1/2 (Supply of the IO-Link ports)
Min. degree of protection of inst. location (Times)IP54
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Rated control supply current IS (Ambient conditions)typ. 60 mA
Description of the input (Supply of the IO-Link ports)NPN (manual start), PNP (autostart)
Degree of pollution (Safety-related characteristic data)2
Number of outputs (Relay outputs: enabling current path)1
Output description (Relay outputs: enabling current path)PNP
Overvoltage category (Safety-related characteristic data)II
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Protective circuit/component (Supply of the IO-Link ports)Suppressor diode
Standards/regulations (Safety-related characteristic data)DIN EN 60947-1
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Input current range "0" signal (Supply of the IO-Link ports)0 mA ... 2 mA
Input voltage range "0" signal (Supply of the IO-Link ports)0 V DC ... 5 V DC
Input voltage range "1" signal (Supply of the IO-Link ports)19.2 V DC ... 30 V DC (manual start, autostart: 0 V)
Rated control circuit supply voltage US (Ambient conditions)24 V DC -20 % / +25 % (provide external protection)
Maximum inrush current (Relay outputs: enabling current path)500 mA (Δt = 1 ms at Us)
Rated insulation voltage (Safety-related characteristic data)320 V
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3
Switching capacity according to IEC 60947-5-1 (IO-Link inputs)4 A (24 V (DC13))
Protective circuit/component (Relay outputs: enabling current path)Suppressor diode
Rated surge voltage/insulation (Safety-related characteristic data)Basic insulation 4 kV between all current paths and housing
Max. permissible overall conductor resistance (Supply of the IO-Link ports)150 Ω

Product Description

Safety relay with IO-Link for emergency stop, protection doors and light barrier up to SIL 3, cat. 4, PL e, 2 sensor circuits, monitored start, manual or automatic, 2 trip circuits, 1 message output,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide