| Parameter | Value |
|---|---|
| GTIN | 4055626276953 |
| Orderkey | 2702412 |
| Catalog page | Page 254 (C-6-2017) |
| Depth (Note) | 114.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 22.5 mm |
| Height (Note) | 117.4 mm |
| (Power supply) | Unless switch-on pulses/light tests are safety-related, they should be disabled. |
| (Digital inputs) | 5 A (250 V (AC15)) |
| Country of origin | DE (Germany) |
| Net weight (Times) | 202.5 g |
| Relay type (Times) | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
| pluggable (General) | Yes |
| Custom tariff number | 85371098 |
| (Ambient conditions) | Protection against polarity reversal for rated control circuit supply voltage |
| Housing color (Times) | yellow |
| Mounting type (Times) | DIN rail mounting |
| Status display (Times) | 3 x green LED |
| Mounting position (Times) | vertical or horizontal |
| Category (Connection data) | 4 |
| Filter time (Power supply) | max. 3 ms (at S12, S22; test pulse width; blanking pulses/dark test) |
| Stripping length (General) | 8 mm |
| Connection method (General) | Spring-cage connection |
| Degree of protection (Times) | IP20 |
| Output fuse (Digital inputs) | 6 A gL/gG (N/O contact) |
| Output name (Digital inputs) | Enabling current path |
| Restart time (Alarm outputs) | < 1 s (Boot time) |
| Assembly instructions (Times) | See derating curve |
| Contact type (Digital inputs) | 3 enabling current paths |
| Designation (Connection data) | EN 62061 |
| Inrush current (Power supply) | < 5 mA (Δt = 500 µs, for Us/Ix at S12) |
| Maximum altitude (Dimensions) | ≤ 2000 m (Above sea level) |
| Recovery time (Alarm outputs) | < 500 ms |
| Nominal operating mode (Times) | 100% operating factor |
| Inrush current (Digital inputs) | min. 10 mA |
| Stop category (Connection data) | 0 |
| Contact material (Digital inputs) | AgSnO2 |
| Operating voltage display (Times) | 1 x green LED |
| Current consumption (Power supply) | < 4 mA (with Us/Ixto S12/S22) |
| Number of outputs (Digital inputs) | 3 (undelayed) |
| Sq. Total current (Digital inputs) | 72 A2(observe derating) |
| Switching voltage (Digital inputs) | min. 5 V AC/DC |
| Inrush current (Ambient conditions) | 2 A (Δt = 300 µs at Us) |
| Output description (Digital inputs) | safety-related N/O contacts |
| Switching capacity (Digital inputs) | min. 50 mW |
| Switching frequency (Digital inputs) | 0.5 Hz |
| Weight per Piece (excluding packing) | 202.500 g |
| (Safety-related characteristic data) | Basic insulation 4 kV between all current paths and housing |
| (Relay outputs: enabling current path) | max. 6 A (Δt = 100 ms) |
| Protective circuit (Ambient conditions) | Surge protection Suppressor diode |
| Mechanical service life (Digital inputs) | 10x 106cycles |
| Performance level (PL) (Connection data) | e (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Typical pickup time at US (Alarm outputs) | < 100 ms (when controlled via A1) |
| Conductor cross section AWG max. (General) | 16 |
| Conductor cross section AWG min. (General) | 24 |
| Shock (Safety-related characteristic data) | 15g for Δt = 11 ms (continuous shock: 10g for Δt = 16 ms) |
| Typical release time at US (Alarm outputs) | < 20 ms (when controlled via A1 or S12) |
| Typical response time at US (Alarm outputs) | < 100 ms (automatic start) |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 60 °C (observe derating) |
| Conductor cross section solid max. (General) | 1.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Limiting continuous current (Digital inputs) | 6 A (observe derating) |
| Power consumption at US (Ambient conditions) | typ. 1.68 W |
| Input current range "0" signal (Power supply) | 0 mA ... 2 mA (for safe Off; at S12 and S22) |
| Input voltage range "0" signal (Power supply) | 0 V DC ... 5 V DC (for safe Off; at S12 and S22) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Safety Integrity Level (SIL) (Connection data) | 3 |
| Conductor cross section flexible max. (General) | 1.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Conformance (Safety-related characteristic data) | CE-compliant |
| Designation (Safety-related characteristic data) | Air clearances and creepage distances between the power circuits |
| Output fuse (Relay outputs: enabling current path) | 1 A gL/gG |
| Output name (Relay outputs: enabling current path) | Signaling current path |
| Contact type (Relay outputs: enabling current path) | 1 signaling current path |
| Min. degree of protection of inst. location (Times) | IP54 |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Rated control supply current IS (Ambient conditions) | typ. 70 mA |
| Inrush current (Relay outputs: enabling current path) | min. 10 mA |
| Interrupting rating (ohmic load) max. (Digital inputs) | 1500 VA (250 V AC, τ = 0 ms) |
| Contact material (Relay outputs: enabling current path) | AgSnO2 |
| Degree of pollution (Safety-related characteristic data) | 2 |
| Number of outputs (Relay outputs: enabling current path) | 1 (undelayed) |
| Sq. Total current (Relay outputs: enabling current path) | 1 A2 |
| Switching voltage (Relay outputs: enabling current path) | min. 5 V AC/DC |
| Output description (Relay outputs: enabling current path) | non-safety-related N/C contact |
| Overvoltage category (Safety-related characteristic data) | II |
| Switching capacity (Relay outputs: enabling current path) | min. 50 mW |
| Max. permissible humidity (storage/transport) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Standards/regulations (Safety-related characteristic data) | DIN EN 60664-1:2008 |
| Switching frequency (Relay outputs: enabling current path) | 0.5 Hz |
| Vibration (operation) (Safety-related characteristic data) | 10 Hz ... 150 Hz, 2g |
| Voltage at input/start and feedback circuit (Power supply) | 24 V DC -20 % / +25 % |
| Max. permissible relative humidity (operation) (Dimensions) | 75 % (on average, 85% infrequently, non-condensing) |
| Rated control circuit supply voltage US (Ambient conditions) | 24 V DC -20 % / +25 % |
| Maximum interrupting rating (inductive load) (Digital inputs) | 48 W (24 V DC, τ = 40 ms) |
| Rated insulation voltage (Safety-related characteristic data) | 250 V AC |
| Safety Integrity Level Claim Limit (SIL CL) (Connection data) | 3 |
| Current (Relay outputs: return current/signaling current path) | max. 100 mA |
| Mechanical service life (Relay outputs: enabling current path) | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 (Digital inputs) | 5 A (24 V (DC13)) |
| Voltage (Relay outputs: return current/signaling current path) | 23 V DC (Us- 1 V) |
| Limiting continuous current (Relay outputs: enabling current path) | 1 A |
| Rated surge voltage/insulation (Safety-related characteristic data) | Basic insulation 4 kV between all current paths |
| Number of outputs (Relay outputs: return current/signaling current path) | 1 (digital) |
| Output description (Relay outputs: return current/signaling current path) | non-safety-related |
| Maximum inrush current (Relay outputs: return current/signaling current path) | 1 A (Δt = 5 ms at Us) |
| Short-circuit protection (Relay outputs: return current/signaling current path) | Yes |
Technical specifications and performance data