Service time: Monday to Friday 9:00-18:00
PSR-MC37-3NO-1NC-24DC-SP - PSR-MC37-3NO-1NC-24DC-SP 2702412 PHOENIX CONTACT Safety relays
In Stock Hot Product

PSR-MC37-3NO-1NC-24DC-SP

PSR-MC37-3NO-1NC-24DC-SP 2702412 PHOENIX CONTACT Safety relays

$0.00USD
3579 in stock
Key Specifications
GTIN:4055626276953
Orderkey:2702412
Catalog page:Page 254 (C-6-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626276953
Orderkey2702412
Catalog pagePage 254 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
Height (Note)117.4 mm
(Power supply)Unless switch-on pulses/light tests are safety-related, they should be disabled.
(Digital inputs)5 A (250 V (AC15))
Country of originDE (Germany)
Net weight (Times)202.5 g
Relay type (Times)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)Protection against polarity reversal for rated control circuit supply voltage
Housing color (Times)yellow
Mounting type (Times)DIN rail mounting
Status display (Times)3 x green LED
Mounting position (Times)vertical or horizontal
Category (Connection data)4
Filter time (Power supply)max. 3 ms (at S12, S22; test pulse width; blanking pulses/dark test)
Stripping length (General)8 mm
Connection method (General)Spring-cage connection
Degree of protection (Times)IP20
Output fuse (Digital inputs)6 A gL/gG (N/O contact)
Output name (Digital inputs)Enabling current path
Restart time (Alarm outputs)< 1 s (Boot time)
Assembly instructions (Times)See derating curve
Contact type (Digital inputs)3 enabling current paths
Designation (Connection data)EN 62061
Inrush current (Power supply)< 5 mA (Δt = 500 µs, for Us/Ix at S12)
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Recovery time (Alarm outputs)< 500 ms
Nominal operating mode (Times)100% operating factor
Inrush current (Digital inputs)min. 10 mA
Stop category (Connection data)0
Contact material (Digital inputs)AgSnO2
Operating voltage display (Times)1 x green LED
Current consumption (Power supply)< 4 mA (with Us/Ixto S12/S22)
Number of outputs (Digital inputs)3 (undelayed)
Sq. Total current (Digital inputs)72 A2(observe derating)
Switching voltage (Digital inputs)min. 5 V AC/DC
Inrush current (Ambient conditions)2 A (Δt = 300 µs at Us)
Output description (Digital inputs)safety-related N/O contacts
Switching capacity (Digital inputs)min. 50 mW
Switching frequency (Digital inputs)0.5 Hz
Weight per Piece (excluding packing)202.500 g
(Safety-related characteristic data)Basic insulation 4 kV between all current paths and housing
(Relay outputs: enabling current path)max. 6 A (Δt = 100 ms)
Protective circuit (Ambient conditions)Surge protection Suppressor diode
Mechanical service life (Digital inputs)10x 106cycles
Performance level (PL) (Connection data)e (5 A DC13; 5 A AC15; 8760 switching cycles/year)
Typical pickup time at US (Alarm outputs)< 100 ms (when controlled via A1)
Conductor cross section AWG max. (General)16
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g for Δt = 11 ms (continuous shock: 10g for Δt = 16 ms)
Typical release time at US (Alarm outputs)< 20 ms (when controlled via A1 or S12)
Typical response time at US (Alarm outputs)< 100 ms (automatic start)
Ambient temperature (operation) (Dimensions)-40 °C ... 60 °C (observe derating)
Conductor cross section solid max. (General)1.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Limiting continuous current (Digital inputs)6 A (observe derating)
Power consumption at US (Ambient conditions)typ. 1.68 W
Input current range "0" signal (Power supply)0 mA ... 2 mA (for safe Off; at S12 and S22)
Input voltage range "0" signal (Power supply)0 V DC ... 5 V DC (for safe Off; at S12 and S22)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Safety Integrity Level (SIL) (Connection data)3
Conductor cross section flexible max. (General)1.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Conformance (Safety-related characteristic data)CE-compliant
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Output fuse (Relay outputs: enabling current path)1 A gL/gG
Output name (Relay outputs: enabling current path)Signaling current path
Contact type (Relay outputs: enabling current path)1 signaling current path
Min. degree of protection of inst. location (Times)IP54
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Rated control supply current IS (Ambient conditions)typ. 70 mA
Inrush current (Relay outputs: enabling current path)min. 10 mA
Interrupting rating (ohmic load) max. (Digital inputs)1500 VA (250 V AC, τ = 0 ms)
Contact material (Relay outputs: enabling current path)AgSnO2
Degree of pollution (Safety-related characteristic data)2
Number of outputs (Relay outputs: enabling current path)1 (undelayed)
Sq. Total current (Relay outputs: enabling current path)1 A2
Switching voltage (Relay outputs: enabling current path)min. 5 V AC/DC
Output description (Relay outputs: enabling current path)non-safety-related N/C contact
Overvoltage category (Safety-related characteristic data)II
Switching capacity (Relay outputs: enabling current path)min. 50 mW
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 60664-1:2008
Switching frequency (Relay outputs: enabling current path)0.5 Hz
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g
Voltage at input/start and feedback circuit (Power supply)24 V DC -20 % / +25 %
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions)24 V DC -20 % / +25 %
Maximum interrupting rating (inductive load) (Digital inputs)48 W (24 V DC, τ = 40 ms)
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3
Current (Relay outputs: return current/signaling current path)max. 100 mA
Mechanical service life (Relay outputs: enabling current path)10x 106cycles
Switching capacity according to IEC 60947-5-1 (Digital inputs)5 A (24 V (DC13))
Voltage (Relay outputs: return current/signaling current path)23 V DC (Us- 1 V)
Limiting continuous current (Relay outputs: enabling current path)1 A
Rated surge voltage/insulation (Safety-related characteristic data)Basic insulation 4 kV between all current paths
Number of outputs (Relay outputs: return current/signaling current path)1 (digital)
Output description (Relay outputs: return current/signaling current path)non-safety-related
Maximum inrush current (Relay outputs: return current/signaling current path)1 A (Δt = 5 ms at Us)
Short-circuit protection (Relay outputs: return current/signaling current path)Yes

Product Description

Safety relay for emergency stop and guard doors as well as elevator applications up to SIL 3, cat. 4, PL e, 1 or 2 channel service, automatic or manual start, short circuit detection, 3 trip circuits,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top