Service time: Monday to Friday 9:00-18:00
PSR-MC32-3NO-1NC-24-230UC-SC - PSR-MC32-3NO-1NC-24-230UC-SC 2700524 PHOENIX CONTACT Safety relays
In Stock Hot Product

PSR-MC32-3NO-1NC-24-230UC-SC

PSR-MC32-3NO-1NC-24-230UC-SC 2700524 PHOENIX CONTACT Safety relays

$0.00USD
3725 in stock
Key Specifications
GTIN:4046356912693
Orderkey:2700524
Catalog page:Page 253 (C-6-2017)
Depth (Note):114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356912693
Orderkey2700524
Catalog pagePage 253 (C-6-2017)
Depth (Note)114.5 mm
Packing unit1 pc
Width (Note)22.5 mm
Height (Note)112.2 mm
(Power supply)Test pulse rate = 5 x Test pulse width
(Digital inputs)4 A gL/gG (for low-demand applications)
Country of originDE (Germany)
Net weight (Times)243.8 g
Relay type (Times)Electromechanical relay with forcibly guided contacts in accordance with EN 50205
pluggable (General)Yes
Custom tariff number85371098
(Ambient conditions)2.9 W (with AC)
Housing color (Times)yellow
Mounting type (Times)DIN rail mounting
Screw thread (General)M3
Status display (Times)3 x green LED
Housing material (Times)PBT
Mounting position (Times)vertical or horizontal
Category (Connection data)4
Filter time (Power supply)max. 1.5 ms (to S10-S12; test pulse width; at 24 V DC)
Stripping length (General)7 mm
Connection method (General)Screw connection
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Degree of protection (Times)IP20
Output fuse (Digital inputs)6 A gL/gG
Output name (Digital inputs)Enabling current path
Assembly instructions (Times)See derating curve
Contact type (Digital inputs)3 enabling current paths
Designation (Connection data)EN 62061
Inrush current (Power supply)< 5 mA (with Us/Ixat S10/S12/S13)
Maximum altitude (Dimensions)≤ 2000 m (Above sea level)
Nominal operating mode (Times)100% operating factor
Inrush current (Digital inputs)min. 10 mA
Stop category (Connection data)0
Filter time (Ambient conditions)2 ms (at A1 in the event of voltage dips at Us)
Contact material (Digital inputs)AgSnO2
Operating voltage display (Times)1 x green LED
Type of protection (Power supply)Inputs: protection against polarity reversal, surge protection
Current consumption (Power supply)< 5 mA (at Us/Ixto S10/S12/S13/S34/S35)
Number of outputs (Digital inputs)3 (undelayed)
Sq. Total current (Digital inputs)72 A2(observe derating)
Switching voltage (Digital inputs)min. 5 V AC/DC
Apparent power (Ambient conditions)typ. 5 VA (at US)
Inrush current (Ambient conditions)< 80 A (Δt = 50 µs at Us)
Output description (Digital inputs)safety-related N/O contacts
Switching capacity (Digital inputs)min. 50 mW
Concurrence input 1/2 (Power supply)
Switching frequency (Digital inputs)max. 1 Hz
Weight per Piece (excluding packing)243.800 g
(Safety-related characteristic data)Safe isolation, reinforced insulation 6 kV between all other circuits
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
(Relay outputs: enabling current path)4 A gL/gG (for low-demand applications)
Protective circuit (Ambient conditions)US: surge protection 275 V varistor / 411 V suppressor diode
Mechanical service life (Digital inputs)10x 106cycles
Performance level (PL) (Connection data)e
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)24
Shock (Safety-related characteristic data)15g
Protective circuit/component (Power supply)38.6 V suppressor diode
Ambient temperature (operation) (Dimensions)-40 °C ... 55 °C (observe derating)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Limiting continuous current (Digital inputs)6 A (observe derating)
Power consumption at US (Ambient conditions)2.7 W (with DC)
Input current range "0" signal (Power supply)0 mA ... 2 mA (for safe Off; at S10/S12/S13)
Input voltage range "0" signal (Power supply)0 V DC ... 5 V DC (for safe Off; at S10/S12/S13)
Utilization restriction (Key Commercial Data)1
Safety Integrity Level (SIL) (Connection data)3
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Conformance (Safety-related characteristic data)CE-compliant
Designation (Safety-related characteristic data)Air clearances and creepage distances between the power circuits
Output fuse (Relay outputs: enabling current path)6 A gL/gG
Output name (Relay outputs: enabling current path)Signaling current path
Contact type (Relay outputs: enabling current path)1 signaling current path
Min. degree of protection of inst. location (Times)IP54
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Rated control supply current IS (Ambient conditions)typ. 103 mA (24 V DC)
Inrush current (Relay outputs: enabling current path)min. 10 mA
Interrupting rating (ohmic load) max. (Digital inputs)1500 VA (250 V AC, τ = 0 ms)
(Relay outputs: return current/signaling current path)< 100 ms (manual, monitored start)
Contact material (Relay outputs: enabling current path)AgSnO2
Degree of pollution (Safety-related characteristic data)2
Number of outputs (Relay outputs: enabling current path)1 (undelayed)
Switching voltage (Relay outputs: enabling current path)min. 5 V AC/DC
Output description (Relay outputs: enabling current path)non-safety-related N/C contact
Overvoltage category (Safety-related characteristic data)III
Switching capacity (Relay outputs: enabling current path)min. 50 mW
Max. permissible humidity (storage/transport) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data)DIN EN 50178; EN 60947-5-1
Switching frequency (Relay outputs: enabling current path)1 Hz
Vibration (operation) (Safety-related characteristic data)10 Hz ... 150 Hz, 2g
Voltage at input/start and feedback circuit (Power supply)24 V DC -20 % / +25 %
Max. permissible relative humidity (operation) (Dimensions)75 % (on average, 85% infrequently, non-condensing)
Max. permissible overall conductor resistance (Power supply)150 Ω
Rated control circuit supply voltage US (Ambient conditions)24 V AC/DC ... 230 V AC/DC -15 % / +10 %
Maximum interrupting rating (inductive load) (Digital inputs)48 W (24 V DC, τ = 40 ms)
Rated insulation voltage (Safety-related characteristic data)250 V AC
Safety Integrity Level Claim Limit (SIL CL) (Connection data)3
Mechanical service life (Relay outputs: enabling current path)10x 106cycles
Switching capacity according to IEC 60947-5-1 (Digital inputs)5 A (24 V (DC13))
Limiting continuous current (Relay outputs: enabling current path)6 A
Rated surge voltage/insulation (Safety-related characteristic data)Basic insulation 4 kV between enabling current path (23/24) and enabling current path (33/34) and signaling current path (41/42)
Restart time (Relay outputs: return current/signaling current path)< 1 s
Recovery time (Relay outputs: return current/signaling current path)< 500 ms
Typical pickup time at US (Relay outputs: return current/signaling current path)< 200 ms (when controlled via A1)
Typical release time at US (Relay outputs: return current/signaling current path)< 20 ms (when actuation is via the sensor circuit)
Typical response time at US (Relay outputs: return current/signaling current path)< 150 ms (automatic start)

Product Description

Safety relay for emergency stop, protection doors and light curtain up to SIL3, cat.4, PLe, 1 or 2 channel service, automatic or manual monitored start, 3 trip circuits, 1 warning current circuit, US=
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top