Key Specifications
GTIN:4055626446899
(Times):IP67 (with SAC cabling)
Orderkey:2702972
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626446899
(Times)IP67 (with SAC cabling)
Orderkey2702972
Packing unit1 pc
(Power supply)max. 150 mA (per safety output)
(Alarm outputs)approx. 100 ms (Test pulse interval)
(Safety outputs)max. 1 V DC (LOW)
Country of originDE (Germany)
Net weight (Times)41.5 g
pluggable (General)no
Custom tariff number85365019
(Ambient conditions)max. 8 A (to be performed externally)
Housing color (Times)yellow
Mounting type (Times)not flush
Status display (Times)2 LEDs
Housing material (Times)PBT
Minimum distance (Times)140 mm (between two safety circuits)
Protection class (Times)III
Mounting position (Times)any
Category (Connection data)4
Delay time (Alarm outputs)typ. 5 ms (Risk time delay per device)
Designation (Power supply)FO1A, FO1B
Connection method (General)Connector
Depth (Key Commercial Data)18 mm
Switching frequency (Times)max. 1 Hz
Test pulses (Alarm outputs)typ. 300 µs (Test pulse duration)
Width (Key Commercial Data)26.5 mm
Degree of protection (Times)IP65/IP67/IP69/IP69K
Designation (Safety outputs)DGN
Height (Key Commercial Data)40 mm
Assembly instructions (Times)Note EN ISO 14119
Current IDGN (Safety outputs)min. 1 mA
Designation (Connection data)EN ISO 13849
Number of positions (General)8
Output voltage (Power supply)min. (UB- 1.5 V (HIGH FO1A, FO1B))
Short-circuit current (Times)typ. 100 A (conditional short-circuit current)
Switch-on time (Alarm outputs)max. 400 ms (for the safety outputs)
Connection technology (General)M12 connector
Output voltage (Safety outputs)min. (UB- 1.5 V (HIGH))
Protection (Ambient conditions)min. 0.25 A (to be performed externally)
Residual current (Power supply)≤ 0.25 mA
Switch-on delay (Alarm outputs)typ. 5 s (after switching UBon)
Discrepancy time (Alarm outputs)max. 10 ms (between the safety outputs)
Number of outputs (Power supply)2
Switching current (Power supply)min. 1 mA (per safety output)
Output description (Power supply)Semiconductor outputs, p-wired
Number of outputs (Safety outputs)1
Short-circuit-proof (Power supply)yes
Output description (Safety outputs)p-wired
Supply voltage (Ambient conditions)24 V DC ±15 % (PELV, controlled, residual ripple
Short-circuit-proof (Safety outputs)yes
Weight per Piece (excluding packing)41.500 g
Current consumption (Ambient conditions)max. 40 mA
Performance level (PL) (Connection data)e
Dimensional drawing (Key Commercial Data)
Note on protection circuit (Power supply)NOTE: Protect the outputs under inductive loads with a freewheeling diode.
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Safety Integrity Level (SIL) (Connection data)3
Risk time according to EN 60947-5-3 (Alarm outputs)max. 260 ms (Stand-alone device)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 70 °C
EMC conformance (Safety-related characteristic data)EN 60947-5-3
Degree of pollution (Safety-related characteristic data)3
Rated surge voltage (Safety-related characteristic data)max. 1.5 kV
Vibration (operation) (Safety-related characteristic data)in accordance with EN 60947-5-2
Rated insulation voltage (Safety-related characteristic data)max. 300 V
Utilization category in accordance with IEC 60947-5-2 (Power supply)150 mA (24 V (DC13))

Product Description

Non-contact safety switch up to cat. 4, PL e (EN ISO 13849), SIL 3 (IEC 61508), Unicode sensor with RFID coding, construction type 4 (EN ISO 14119), manual or automatic start, integrated diagnostics,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty