| Parameter | Value |
|---|---|
| GTIN | 4046356078993 |
| Orderkey | 2708863 |
| Catalog page | Page 318 (C-6-2017) |
| Depth (Note) | 105 mm |
| Packing unit | 1 pc |
| Width (Note) | 35 mm |
| (Dimensions) | ≤ 2000 m (When used in EX zone 2) |
| Height (Note) | 99 mm |
| Country of origin | DE (Germany) |
| (Digital outputs) | Class I, Div. 2, Groups A, B, C, D |
| (Serial interface) | 150 V AC (0.46 A) |
| Custom tariff number | 85176200 |
| (Ambient conditions) | Class I, Div. 2, Groups A, B, C, D |
| Altitude (Dimensions) | ≤ 5000 m (For restrictions see manufacturer's declaration) |
| ATEX (Digital outputs) | II 3 G Ex nA nC IIC T4 Gc X |
| Signal (Digital outputs) | ± 1 kV |
| ATEX (Ambient conditions) | II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| MTBF (Ambient conditions) | 1136 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| MTTF (Ambient conditions) | 1638 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| Color (Ambient conditions) | green |
| Comments (Digital outputs) | Criterion B |
| Dimensional drawing (Note) | |
| Interface 1 (Power supply) | PROFIBUS acc. to IEC 61158, RS-485 2-conductor |
| Noise immunity (Dimensions) | EN 61000-4-2 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Conformance (Digital outputs) | CE-compliant |
| Designation (Digital outputs) | Air clearances and creepage distances |
| Operating mode (Power supply) | Through PROFIBUS connector |
| Output current (Power supply) | 50 mA |
| Test result (Digital outputs) | 15g, 11 ms period, half-sine shock pulse |
| Bit delay (Ambient conditions) | 1 bit (Direct mode) |
| Output name (Serial interface) | Relay output |
| Supply voltage range (General) | 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
| Type of test (Digital outputs) | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
| Net weight (Ambient conditions) | 212.4 g |
| Conformance (Ambient conditions) | CE-compliant |
| Connection method (Power supply) | D-SUB-9 female connector |
| Noise emission (Digital outputs) | EN 55011 |
| Noise immunity (Digital outputs) | EN 61000-4-2 |
| Nominal supply voltage (General) | 24 V DC (With UL approval) |
| UL, USA/Canada (Digital outputs) | cULus listed UL 508 |
| Degree of protection (Dimensions) | IP20 |
| File format/coding (Power supply) | UART (11 Bit, NRZ) |
| Frequency range (Digital outputs) | 80 MHz ... 3 GHz |
| Noxious gas test (Digital outputs) | ISA-S71.04-1985 G3 Harsh Group A |
| Transmission length (Power supply) | ≤ 1200 m (Depends on transmission speed and cable type) |
| Transmission medium (Power supply) | 2-wire twisted pair, shielded |
| Contact discharge (Digital outputs) | ± 6 kV |
| Noise emission (Ambient conditions) | EN 55011 |
| Termination resistor (Power supply) | external |
| UL, USA/Canada (Ambient conditions) | cULus listed UL 508 |
| Number of outputs (Serial interface) | 1 |
| Weight per Piece (excluding packing) | 212.400 g |
| Housing material (Ambient conditions) | PA 6.6-FR |
| Output description (Serial interface) | Alarm output |
| Output nominal voltage (Power supply) | 5 V DC ±5 % |
| Typical current consumption (General) | < 90 mA (24 V DC) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Data direction switching (Power supply) | Automatic control, min. station response time 2 bits |
| Standards/regulations (Digital outputs) | DIN EN 50178, DIN EN 60950 |
| Electrical isolation (Ambient conditions) | VCC // TBUS // PROFIBUS (A) // PROFIBUS (B) |
| Bit distortion, input (Ambient conditions) | max. ± 35 % |
| Transmission channels (Ambient conditions) | 2 (1/1), TD, RD, half duplex |
| Bit distortion, output (Ambient conditions) | < 6.25 % |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 60 °C |
| Maximum switching voltage (Serial interface) | 30 V DC (1 A) |
| Permissible humidity (operation) (Dimensions) | 30 % ... 95 % (non-condensing) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Conductor cross section AWG max. (Power supply) | 14 |
| Conductor cross section AWG min. (Power supply) | 24 |
| Electromagnetic compatibility (Digital outputs) | Conformance with EMC Directive 2014/30/EU |
| Conductor cross section solid max. (Power supply) | 2.5 mm² |
| Conductor cross section solid min. (Power supply) | 0.2 mm² |
| Test voltage data interfaces (Ambient conditions) | 1.5 kV |
| Connection in acc. with standard (Digital outputs) | CUL |
| Electromagnetic compatibility (Ambient conditions) | Conformance with EMC Directive 2014/30/EU |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Conductor cross section flexible max. (Power supply) | 2.5 mm² |
| Conductor cross section flexible min. (Power supply) | 0.2 mm² |
| Test voltage data interface/power supply (Ambient conditions) | 1.5 kVrms(50 Hz, 1 min.) |
| Free from substances that could impair the application of coating (Digital outputs) | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
Technical specifications and performance data