| Parameter | Value |
|---|---|
| 100 V AC ... 109 V AC -15 % ... +10 % (PN= 200 W) | |
| Time | 23000 h |
| Color | green |
| Depth | 125 mm |
| Input | 4 kV (Test Level 4 - asymmetrical) |
| Width | 60 mm |
| rigid | 0.75 mm² ... 2.5 mm² |
| Height | 124 mm |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Current | 10 A |
| LED off | Supply voltage input AC not present (Off) |
| Voltage | 10 V (Test Level 3) |
| Comments | Criterion A |
| Function | Visual operating state display |
| Position | 1.x |
| flexible | 0.75 mm² ... 2.5 mm² |
| Frequency | 50 Hz |
| Rise time | < 100 ms (UOut= 10 % ... 90 %) |
| EN 61010-1 | II (≤ 3000 m) |
| Efficiency | typ. 91 % (120 V AC) |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Temperature | 40 °C |
| Voltage dip | 70 % |
| rigid (AWG) | 18 ... 14 (Cu) |
| Crest factor | typ. 1.5 (120 V AC) |
| Hood version | Stainless steel |
| Input/Output | asymmetrical |
| Product type | Power supply |
| Mounting type | DIN rail mounting |
| No-load proof | yes |
| Climatic class | 3K22 (in accordance with EN 60721-3-3) |
| Identification | 1.1 (), 1.2 (L), 1.3 (N) |
| Inrush current | typ. 30 A (at 25 °C) |
| Noise emission | EN 55016 |
| Product family | ESSENTIAL POWER |
| Switch-on time | typ. 1 s |
| Additional text | 120 V AC |
| Frequency range | 0 kHz ... 2 kHz |
| Residual ripple | typ. 70 mVPP(with nominal values) |
| Discharge in air | 8 kV (Test Level 3) |
| Housing material | Metal |
| Maximum altitude | ≤ 3000 m (> 2000 m, Derating: 10 %/1000 m) |
| Number of phases | 1.00 |
| Protection class | I |
| Stripping length | 6.5 mm |
| Connection method | Screw connection |
| Contact discharge | 6 kV (Test Level 3) |
| Control deviation | < 2 % (change in load, static 10 % ... 90 %) |
| Device mains fuse | 5 A internal (device protection), fast-blow |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Number of periods | 25 periods |
| Output power (PN) | 240 W (240 V AC) |
| Shock (operation) | 15 ms, 15 g, per spatial direction (IEC 60068-2-27) |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Protective circuit | Transient protection; Varistor |
| Types of signaling | LED DC OK – signal state operation (UN= 24 V DC, IOut= IN) |
| Current consumption | max. 3 A (240 W) |
| Degree of pollution | 2 |
| Foot latch material | Sheet steel, zinc-plated |
| Input voltage range | 110 V AC ... 240 V AC ±10 % (PN= 240 W) |
| Short-circuit-proof | yes |
| Test field strength | 10 V/m (Test Level 3) |
| Connection in series | yes, for increased output voltage |
| Degree of protection | IP20 |
| Frequency range (fN) | 50 Hz ... 60 Hz ±10 % |
| Mains buffering time | typ. 30 ms (120 V AC) |
| Side element version | Aluminum |
| Standard designation | Electrical safety |
| Assembly instructions | alignable: 0 mm horizontally, 30 mm vertically |
| Drive form screw head | Slotted L |
| Interference emission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| LED on (green), DC OK | UOUT> 11 V (On (green), DC OK) |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Standards/regulations | EN 61000-3-2 |
| Vibration (operation) | 10 Hz ... 50 Hz, amplitude ±0.2 mm |
| Connection in parallel | yes, for increasing power and redundancy with diode |
| Nominal output voltage | 24 V DC |
| Discharge current to PE | < 3.5 mA |
| MTBF (Telcordia SR-332) | > 1170000 h (25 °C) |
| With protective coating | No |
| Conducted noise emission | EN 55016 |
| Standards/specifications | IEC 61010-2-201 (SELV) |
| Integrated fuse protection | no |
| Feedback voltage resistance | ≤ 35 V DC |
| Nominal input voltage range | 100 V AC ... 240 V AC |
| Nominal output current (IN) | max. 10 A (PN= 240 W) |
| Supply system configuration | TN, TT, IT (PE) |
| Power loss nominal load max. | < 20 W (230 V AC) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Inrush current integral (I2t) | typ. 0.2 A2s |
| Insulation voltage input / PE | 3.5 kV AC (type test) |
| Typical national grid voltage | 120 V AC |
| Voltage type of supply voltage | AC |
| Ambient temperature (operation) | -20 °C ... 70 °C (Derating >45°C: 2.5%/K) |
| Insulation voltage input/output | 4 kV AC (type test) |
| Installation distance right/left | 10 mm / 10 mm |
| Installation distance top/bottom | 30 mm / 30 mm |
| Maximum no-load power dissipation | < 3 W (230 V AC) |
| Minimum no-load power dissipation | < 3 W (120 V AC) |
| EMC requirements for noise immunity | EN 61000-6-2 |
| Minimum nominal load power dissipation | < 24 W (120 V AC) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Recommended breaker for input protection | 6 A ... 16 A (Characteristic B, C, D, K or comparable) |
| flexible with ferrule with plastic sleeve | 0.75 mm² ... 2.5 mm² |
| Setting range of the output voltage (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| flexible with ferrule without plastic sleeve | 0.75 mm² ... 2.5 mm² |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Protection against overvoltage at the output (OVP) | ≤ 35 V DC |
Technical specifications and performance data
Installation and operation guide