Key Specifications
:100 V AC ... 109 V AC -15 % ... +10 % (PN= 100 W)
Time:24000 h
Color:green
Depth:125 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
100 V AC ... 109 V AC -15 % ... +10 % (PN= 100 W)
Time24000 h
Colorgreen
Depth125 mm
Input4 kV (Test Level 4 - asymmetrical)
Width40 mm
rigid0.5 mm² ... 2.5 mm²
Height124 mm
Output2 kV (Test Level 3 - asymmetrical)
Current5 A
LED offSupply voltage input AC not present (Off)
Voltage10 V (Test Level 3)
CommentsCriterion A
FunctionVisual operating state display
Position1.x
flexible0.5 mm² ... 2.5 mm²
Frequency50 Hz
Rise time< 2 s (UOut= 10 % ... 90 %)
EN 61010-1II (≤ 3000 m)
Efficiencytyp. 87 % (120 V AC)
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Temperature40 °C
Voltage dip70 %
rigid (AWG)20 ... 14 (Cu)
Crest factortyp. 1.5 (120 V AC)
Hood versionStainless steel
Input/Outputasymmetrical
Product typePower supply
Mounting typeDIN rail mounting
No-load proofyes
Climatic class3K22 (in accordance with EN 60721-3-3)
Identification1.1 (), 1.2 (L), 1.3 (N)
Inrush currenttyp. 43 A (at 25 °C)
Noise emissionEN 55016
Product familyESSENTIAL POWER
Switch-on timetyp. 1 s
Additional text120 V AC
Frequency range0 kHz ... 2 kHz
Residual rippletyp. 70 mVPP(with nominal values)
Discharge in air8 kV (Test Level 3)
Housing materialMetal
Maximum altitude≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Number of phases1.00
Protection classI
Stripping length6.5 mm
Connection methodScrew connection
Contact discharge6 kV (Test Level 3)
Control deviation< 2 % (change in load, static 10 % ... 90 %)
Device mains fuse3.15 A internal (device protection), fast-blow
Mounting positionhorizontal DIN rail NS 35, EN 60715
Number of periods25 periods
Output power (PN)120 W (240 V AC)
Shock (operation)15 ms, 15 g, per spatial direction (IEC 60068-2-27)
Tightening torque0.5 Nm ... 0.6 Nm
Protective circuitTransient protection; Varistor
Types of signalingLED DC OK – signal state operation (UN= 24 V DC, IOut= IN)
Current consumptionmax. 2 A (120 W)
Degree of pollution2
Foot latch materialSheet steel, zinc-plated
Input voltage range110 V AC ... 240 V AC ±10 % (PN= 120 W)
Short-circuit-proofyes
Test field strength10 V/m (Test Level 3)
Connection in seriesyes, for increased output voltage
Degree of protectionIP20
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 15 ms (120 V AC)
Side element versionAluminum
Standard designationElectrical safety
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically
Drive form screw headSlotted L
Interference emissionInterference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
LED on (green), DC OKUOUT> 15 V (On (green), DC OK)
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Standards/regulationsEN 61000-3-2
Vibration (operation)10 Hz ... 50 Hz, amplitude ±0.2 mm
Connection in parallelyes, for increasing power and redundancy with diode
Nominal output voltage24 V DC
Discharge current to PE< 3.5 mA
MTBF (Telcordia SR-332)> 2470000 h (25 °C)
With protective coatingNo
Conducted noise emissionEN 55016
Standards/specificationsIEC 61010-2-201 (SELV)
Integrated fuse protectionno
Feedback voltage resistance≤ 35 V DC
Nominal input voltage range100 V AC ... 240 V AC
Nominal output current (IN)max. 5 A (PN= 120 W)
Supply system configurationTN, TT, IT (PE)
Power loss nominal load max.< 16 W (230 V AC)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Inrush current integral (I2t)typ. 0.7 A2s
Insulation voltage input / PE3.5 kV AC (type test)
Typical national grid voltage120 V AC
Voltage type of supply voltageAC
Ambient temperature (operation)-20 °C ... 70 °C (Derating >45°C: 2.5%/K)
Insulation voltage input/output4 kV AC (type test)
Installation distance right/left10 mm / 10 mm
Installation distance top/bottom30 mm / 30 mm
Maximum no-load power dissipation< 1 W (230 V AC)
Minimum no-load power dissipation< 1 W (120 V AC)
EMC requirements for noise immunityEN 61000-6-2
Minimum nominal load power dissipation< 20 W (120 V AC)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Recommended breaker for input protection10 A ... 16 A (Characteristic B, C, D, K or comparable)
flexible with ferrule with plastic sleeve0.5 mm² ... 2.5 mm²
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
flexible with ferrule without plastic sleeve0.5 mm² ... 2.5 mm²
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Protection against overvoltage at the output (OVP)≤ 35 V DC

Product Description

Primary Switching Power Supplies, ESSENTIAL POWER, Screw Connection, Rail Mount, Output: 24 VDC / 5 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top