| Parameter | Value |
|---|---|
| GTIN | 4055626807560 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1081233 |
| (General) | 31.2 mm |
| Packing unit | 50 pc |
| Pitch (General) | 8.2 mm |
| Width (General) | 8.2 mm |
| Height (General) | 49.3 mm |
| Length (General) | 21 mm |
| Country of origin | PL (Poland) |
| Custom tariff number | 85366990 |
| (Key Commercial Data) | Plant engineering |
| Minimum order quantity | 50 pc |
| Color (Key Commercial Data) | orange |
| Stripping length (Dimensions) | 12 mm |
| Connection method (Dimensions) | Push-in connection |
| Potentials (Key Commercial Data) | 1 |
| Weight per Piece (excluding packing) | 7.500 g |
| Open side panel (Key Commercial Data) | No |
| Internal cylindrical gage (Dimensions) | A5 |
| Number of levels (Key Commercial Data) | 1 |
| Nominal current IN (Key Commercial Data) | 41 A |
| Nominal voltage UN (Key Commercial Data) | 1000 V |
| Area of application (Key Commercial Data) | Railway industry |
| Degree of pollution (Key Commercial Data) | 3 |
| Insulating material (Key Commercial Data) | PA |
| Number of positions (Key Commercial Data) | 1 |
| Rated surge voltage (Key Commercial Data) | 8 kV |
| Maximum load current (Key Commercial Data) | 41 A (with 6 mm² conductor cross section) |
| Overvoltage category (Key Commercial Data) | III |
| Nominal cross section (Key Commercial Data) | 6 mm² |
| Number of connections (Key Commercial Data) | 1 |
| Conductor cross section AWG max. (Dimensions) | 8 |
| Conductor cross section AWG min. (Dimensions) | 20 |
| Connection in acc. with standard (Dimensions) | IEC 61984 |
| Conductor cross section solid max. (Dimensions) | 10 mm² |
| Conductor cross section solid min. (Dimensions) | 0.5 mm² |
| Insulating material group (Key Commercial Data) | I |
| Conductor cross section flexible max. (Dimensions) | 6 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.5 mm² |
| Connection in acc. with standard (Connection data) | IEC 61984 |
| Max. AWG conductor cross section, flexible (Dimensions) | 10 |
| Min. AWG conductor cross section, flexible (Dimensions) | 20 |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Maximum power dissipation for nominal condition (Key Commercial Data) | 1.31 W |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 6 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 6 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) | 1.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) | 0.5 mm² |
Technical specifications and performance data