| Parameter | Value |
|---|---|
| GTIN | 4055626285627 |
| Note | Made to Order (non-returnable) |
| Orderkey | 3211289 |
| (General) | 25.6 mm |
| Catalog page | Page 296 (C-1-2017) |
| Packing unit | 25 pc |
| Pitch (General) | 5.2 mm |
| Width (General) | 52 mm |
| Height (General) | 41.2 mm |
| Length (General) | 16 mm |
| Country of origin | PL (Poland) |
| Custom tariff number | 85366990 |
| (Key Commercial Data) | Plant engineering |
| Minimum order quantity | 25 pc |
| Color (Key Commercial Data) | gray |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Stripping length (Dimensions) | 8 mm ... 10 mm |
| Connection method (Dimensions) | Push-in connection |
| Potentials (Key Commercial Data) | 10 |
| Weight per Piece (excluding packing) | 34.540 g |
| Open side panel (Key Commercial Data) | No |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Internal cylindrical gage (Dimensions) | A3 |
| Number of levels (Key Commercial Data) | 1 |
| Nominal current IN (Key Commercial Data) | 24 A |
| Nominal voltage UN (Key Commercial Data) | 800 V |
| Area of application (Key Commercial Data) | Machine building |
| Degree of pollution (Key Commercial Data) | 3 |
| Insulating material (Key Commercial Data) | PA |
| Number of positions (Key Commercial Data) | 10 |
| Rated surge voltage (Key Commercial Data) | 6 kV |
| Maximum load current (Key Commercial Data) | 24 A (with 4 mm² conductor cross section) |
| Overvoltage category (Key Commercial Data) | III |
| Nominal cross section (Key Commercial Data) | 2.5 mm² |
| Number of connections (Key Commercial Data) | 10 |
| Conductor cross section AWG max. (Dimensions) | 12 |
| Conductor cross section AWG min. (Dimensions) | 26 |
| Connection in acc. with standard (Dimensions) | IEC 61984 |
| Conductor cross section solid max. (Dimensions) | 4 mm² |
| Conductor cross section solid min. (Dimensions) | 0.14 mm² |
| Insulating material group (Key Commercial Data) | I |
| Conductor cross section flexible max. (Dimensions) | 2.5 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.14 mm² |
| Connection in acc. with standard (Connection data) | IEC 61984 |
| Max. AWG conductor cross section, flexible (Dimensions) | 14 |
| Min. AWG conductor cross section, flexible (Dimensions) | 26 |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Maximum power dissipation for nominal condition (Key Commercial Data) | 0.77 W (the value is based on one connection block and is multiplied according to the pin assignment) |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 2.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.14 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) | 0.5 mm² |
Technical specifications and performance data
Installation and operation guide