| Parameter | Value |
|---|---|
| • The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product. | |
| Note | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
| Pitch | 10 mm |
| Width [w] | 54.4 mm |
| Height [h3] | 43 mm |
| Height [h4] | 42.8 mm |
| Length [l1] | 25.7 mm |
| Length [l2] | 20.27 mm |
| Safety note | • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. |
| Product type | Panel feed-through terminal block |
| Specification | IEC 60947-1:2007-06 + A1:2010-12 |
| Product family | PLW 16 |
| Color (Housing) | gray (7042) |
| Article revision | 03 |
| Connector system | PLW 16-6 |
| Contact material | Cu alloy |
| Stripping length | 18 mm |
| Connection method | Push-lock connection |
| Type of packaging | packed in cardboard |
| Nominal current IN | 41 A |
| Nominal voltage UN | 1000 V |
| Dimensional drawing | |
| Insulating material | PA |
| Number of positions | 3 |
| Number of potentials | 2 |
| Rated voltage (II/2) | 1000 V |
| Nominal cross section | 16 mm² |
| Number of connections | 2 |
| Rated voltage (III/2) | 1000 V |
| Rated voltage (III/3) | 1000 V |
| Surface characteristics | tin-plated |
| Insulating material group | I |
| Solder pins per potential | 1 |
| CTI according to IEC 60112 | 600 |
| Rated surge voltage (II/2) | 6 kV |
| Rated surge voltage (III/2) | 8 kV |
| Rated surge voltage (III/3) | 8 kV |
| Conductor cross section rigid | 2.5 mm² ... 16 mm² |
| Ambient temperature (assembly) | -5 °C ... 105 °C |
| Ambient temperature (operation) | -40 °C ... 100 °C (Depending on the current carrying capacity/derating curve) |
| Rated insulation voltage (II/2) | 1000 V |
| Conductor cross section flexible | 2.5 mm² ... 25 mm² |
| Rated insulation voltage (III/2) | 1000 V |
| Rated insulation voltage (III/3) | 1000 V |
| minimum creepage distance (II/2) | 5 mm |
| minimum creepage distance (III/2) | 5 mm |
| minimum creepage distance (III/3) | 12.5 mm |
| Relative humidity (storage/transport) | 30 % ... 70 % |
| Flammability rating according to UL 94 | V0 |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Comparative tracking index (IEC 60112) | CTI 600 |
| minimum clearance value - non-homogenous field (II/2) | 5.5 mm |
| minimum clearance value - non-homogenous field (III/2) | 8 mm |
| minimum clearance value - non-homogenous field (III/3) | 8 mm |
| Connection direction of the conductor to plug-in direction | 0 ° |
| Glow wire flammability index GWFI according to EN 60695-2-12 | 850 |
| Glow wire ignition temperature GWIT according to EN 60695-2-13 | 775 |
| Temperature for the ball pressure test according to EN 60695-10-2 | 125 °C |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 2.5 mm² ... 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 2.5 mm² ... 16 mm² |