| Parameter | Value |
|---|---|
| GTIN | 4046356458290 |
| Orderkey | 1770416 |
| Catalog page | Page 473 (C-1-2013) |
| Packing unit | 25 pc |
| Country of origin | SK (Slovakia) |
| Custom tariff number | 85369010 |
| Minimum order quantity | 25 pc |
| Pitch (Key Commercial Data) | 10 mm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Height (Key Commercial Data) | 29 mm |
| Stripping length (Dimensions) | 18 mm |
| Range of articles (Dimensions) | PLH 16/ |
| Nominal current IN (Dimensions) | 76 A |
| Solder pin surface (Dimensions) | |
| Insulating material (Dimensions) | PA |
| Number of positions (Dimensions) | 4 |
| Dimension a (Key Commercial Data) | 30 mm |
| Pin spacing (Key Commercial Data) | 12.5 mm |
| Rated voltage (II/2) (Dimensions) | 800 V |
| Width [ w ] (Key Commercial Data) | 41.4 mm |
| Height [ h ] (Key Commercial Data) | 33.5 mm |
| Length [ l ] (Key Commercial Data) | 30.5 mm |
| Nominal cross section (Dimensions) | 16 mm² |
| Rated voltage (III/2) (Dimensions) | 400 V |
| Rated voltage (III/3) (Dimensions) | 400 V |
| Hole diameter (Key Commercial Data) | 1.6 mm |
| Solder pin [P] (Key Commercial Data) | 4.5 mm |
| Weight per Piece (excluding packing) | 32.810 g |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Insulating material group (Dimensions) | I |
| Rated surge voltage (II/2) (Dimensions) | 4 kV |
| Rated surge voltage (III/2) (Dimensions) | 4 kV |
| Rated surge voltage (III/3) (Dimensions) | 4 kV |
| Conductor cross section AWG max. (General) | 4 |
| Conductor cross section AWG min. (General) | 18 |
| Conductor cross section solid max. (General) | 16 mm² |
| Conductor cross section solid min. (General) | 0.75 mm² |
| Conductor cross section flexible max. (General) | 25 mm² |
| Conductor cross section flexible min. (General) | 0.75 mm² |
| Connection in acc. with standard (Connection data) | UL |
| Flammability rating according to UL 94 (Dimensions) | V0 |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (General) | 10 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (General) | 0.75 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (General) | 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (General) | 0.75 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (General) | 4 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (General) | 0.75 mm² |
Technical specifications and performance data