Key Specifications
:Surge protection
Note:Device supply and 8 x inputs
Depth:82.5 mm
Width:50 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Surge protection
NoteDevice supply and 8 x inputs
Depth82.5 mm
Width50 mm
Height48.5 mm
GeneralFor proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met.
Data rate19200 Baud
InsulationBasic insulation
Product typeBase unit
Buffer period96 h (Capacitor)
Input voltage24 V DC
Mounting typePlug-in mounting
Operating mode100% operating factor
Product familyPLC logic
Realtime clockYes
Status displayYellow LED
Supply voltage24 V DC
Nominal current9 mA
Input resistance> 3.5 kΩ
Number of inputs8 (2 configurable as analog)
Pollution degree2
Stripping length9 mm
Connection methodPush-in connection
Cross section AWG(converted acc. to IEC)
Mounting positionany
Number of outputs≤ 8
Protective circuitReverse polarity protection
Dimensional drawing
Input voltage range0 V ... 10 V
Number of positions10
Protocols supportedModbus/RTU
Rated surge voltage0.8 kV
Degree of protectionIP20
Overvoltage categoryIII
Supply voltage range19.2 V DC ... 26.4 V DC
Termination resistor150 Ω
Assembly instructionscan be plugged onto 8 x PLC-INTERFACE terminal blocks
Number of connections1
Standards/regulationsDIN EN 50178
Nominal output voltage24 V DC
Accuracy realtime clock±2 s/d
Signal level "0" signal< 5 V
Signal level "1" signal> 11 V
Description of the inputEN 61131-2, type 3
Input current "0" signal< 1 mA
Input current "1" signal2.5 mA
Rated insulation voltage50 V
Conductor cross section AWG26 ... 16
Maximum input current at UN160 mA
Typical current consumption4 mA
Typical input current at UN40 mA
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Ambient temperature (operation)-20 °C ... 50 °C
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Ambient temperature (storage/transport)-20 °C ... 70 °C
Max. permissible relative humidity (operation)95 %

Product Description

PLC logic expansion module with 16 I/Os for plug-in connection to 8 PLC-INTERFACE terminals for expansion of the basic module (maximum 2 expansion modules can be connected to one basic module),
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide