ParameterValue
GTIN4046356919166
NoteMade to Order (non-returnable)
(Note)Surge protection
Orderkey2905135
(General)0.25 mm² ... 1.5 mm² (Ferrules without plastic sleeve)
Catalog pagePage 455 (C-7-2015)
Packing unit1 pc
Country of originDE (Germany)
Color (Output data)green
Custom tariff number85371098
Status display (Note)Green LED
Supply voltage (Note)24 V DC
Insulation (Dimensions)Basic insulation
Conformance (Dimensions)CE-compliant
Designation (Dimensions)Air clearances and creepage distances between the power circuits
Protective circuit (Note)Reverse polarity protection
Depth (Ambient conditions)87 mm
Stripping length (General)9 mm
Width (Ambient conditions)50 mm
Connection method (General)Push-in connection
Height (Ambient conditions)111 mm
Supply voltage range (Note)19.2 V DC ... 26.4 V DC
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Input voltage (Power supply)24 V DC
Operating mode (Output data)100% operating factor
Number of positions (General)10
Status display (Power supply)Yellow LED
Mounting position (Output data)any
Number of connections (General)1
Number of inputs (Power supply)8 (2 configurable as analog)
Degree of pollution (Dimensions)2
Rated surge voltage (Dimensions)0.8 kV
Overvoltage category (Dimensions)III
Degree of protection (Output data)IP20
Maximum input current at UN (Note)120 mA
Standards/regulations (Dimensions)DIN EN 50178
Assembly instructions (Output data)can be plugged onto 8 x PLC-INTERFACE terminal blocks
Input voltage (Input data (analog))19 V DC
Weight per Piece (excluding packing)136.000 g
Conductor cross section AWG (General)26 ... 16
Rated insulation voltage (Dimensions)50 V
Realtime clock accuracy (Output data)±2 s/d
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Input resistance (Input data (analog))< 100 mΩ
Number of inputs (Input data (analog))≤ 8
Signal level "0" signal (Power supply)< 5 V
Signal level "1" signal (Power supply)> 11 V
Conductor cross section solid (General)0.14 mm² ... 1.5 mm²
Description of the input (Power supply)EN 61131-2, type 3
Input current "0" signal (Power supply)< 1 mA
Input current "1" signal (Power supply)typ. 2.5 mA
Input resistance (Input data (digital))> 3.5 kΩ
Number of inputs (Input data (digital))2 (IN6 and IN7 are configurable as analog)
Realtime clock buffer time (Output data)24 h (Capacitor)
Conductor cross section flexible (General)0.14 mm² ... 1.5 mm²
Input voltage range (Input data (digital))0 V ... 10 V
Nominal current (Input data (PLC-INTERFACE))9 mA
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Description of the input (Input data (analog))technical data depends on the PLC-INTERFACE terminal block used
Number of outputs (Input data (PLC-INTERFACE))≤ 8
Connection method (Connection data (PLC V8C bus))S-PORT (socket)
Typical current consumption (Input data (analog))4 mA
Nominal output voltage (Input data (PLC-INTERFACE))24 V DC
Number of positions (Connection data (PLC V8C bus))12
Number of connections (Connection data (PLC V8C bus))1
Connection method (Connection data (INTERFACE system))Insulation displacement connection
Number of positions (Connection data (INTERFACE system))4
Ambient temperature (operation) (Connection data (memory))-20 °C ... 45 °C
Number of connections (Connection data (INTERFACE system))1
Stripping length (Connection data (programming interface))6 mm
Connection method (Connection data (programming interface))Spring-cage connection
Number of positions (Connection data (programming interface))3
Connection method (Connection data (supply and digital inputs))Micro USB type B
Number of connections (Connection data (programming interface))1
Ambient temperature (storage/transport) (Connection data (memory))-20 °C ... 70 °C
Number of connections (Connection data (supply and digital inputs))1
Conductor cross section AWG (Connection data (programming interface))26 ... 20
Conductor cross section solid (Connection data (programming interface))0.14 mm² ... 0.5 mm²
Max. permissible relative humidity (operation) (Connection data (memory))95 %
Conductor cross section flexible (Connection data (programming interface))0.2 mm² ... 0.5 mm²