| Parameter | Value |
|---|---|
| GTIN | 4046356147330 |
| Orderkey | 2982663 |
| (General) | EN 50178 |
| Catalog page | Page 420 (C-5-2017) |
| Depth (Note) | 86 mm |
| Packing unit | 10 pc |
| Width (Note) | 6.2 mm |
| (Input data) | UVN- UR;in blocking state |
| Height (Note) | 80 mm |
| Country of origin | DE (Germany) |
| (Connection data 2) | EN 50178 |
| Custom tariff number | 85364190 |
| Insulation (General) | Basic insulation |
| (Ambient conditions) | 0 mA ... 0.35 mA (In the event of a wire break) |
| Designation (General) | Air clearances and creepage distances |
| Indication (Input data) | Red LED |
| Designation (Input data) | Alarm output |
| Status display (Input data) | Green LED |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Connection name (Output data) | Input side |
| Degree of pollution (General) | 2 |
| Rated surge voltage (General) | 0.4 kV |
| Overvoltage category (General) | I |
| Stripping length (Output data) | 8 mm |
| Connection method (Output data) | Screw connection |
| Designation (Connection data 2) | Air clearances and creepage distances |
| Standards/regulations (General) | IEC 60664 |
| Type of protection (Input data) | Surge protection |
| Designation (Ambient conditions) | Control circuit |
| Cable length (Ambient conditions) | < 30 m |
| Degree of protection (Dimensions) | IP20 |
| Operating mode (Connection data 2) | 100% operating factor |
| Rated insulation voltage (General) | 50 V DC |
| Connection name (Connection data 1) | Output side |
| Output nominal voltage (Input data) | UVN- URes |
| Transmission frequency (Input data) | approx. 350 Hz |
| Stripping length (Connection data 1) | 8 mm |
| Switching point (Ambient conditions) | ≥ 2.1 mA (In conductive state) |
| Weight per Piece (excluding packing) | 35.540 g |
| Connection method (Connection data 1) | Screw connection |
| Mounting position (Connection data 2) | any |
| Non-load voltage (Ambient conditions) | 8.2 V DC ±10 % |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Degree of pollution (Connection data 2) | 2 |
| Type of protection (Ambient conditions) | Surge protection |
| Input voltage range (Ambient conditions) | 19.2 V DC ... 28.8 V DC |
| Internal resistance (Ambient conditions) | approx. 1 kΩ |
| Limiting continuous current (Input data) | 50 mA |
| Overvoltage category (Connection data 2) | I |
| Assembly instructions (Connection data 2) | In rows with zero spacing |
| Conductor cross section AWG (Output data) | 26 ... 12 |
| Protective circuit/component (Input data) | Suppressor diode |
| Standards/regulations (Connection data 2) | IEC 60664 |
| Switching hysteresis (Ambient conditions) | approx. 0.2 mA |
| Conductor cross section solid (Output data) | 0.14 mm² ... 2.5 mm² |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 50 °C |
| Max. current consumption (Ambient conditions) | approx. 70 mA (at 50 mA output current) |
| Nominal input voltage UN (Ambient conditions) | 8.2 V DC ±10 % |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Conductor cross section flexible (Output data) | 0.14 mm² ... 2.5 mm² |
| Operating voltage display (Ambient conditions) | Green LED |
| Conductor cross section AWG (Connection data 1) | 26 ... 12 |
| Flammability rating according to UL 94 (General) | V0 |
| Typical input current at UN (Ambient conditions) | approx. 14 mA |
| Conductor cross section solid (Connection data 1) | 0.14 mm² ... 2.5 mm² |
| Protective circuit/component (Ambient conditions) | Suppressor diode |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Conductor cross section flexible (Connection data 1) | 0.14 mm² ... 2.5 mm² |
| Flammability rating according to UL 94 (Connection data 2) | V0 |
| Input voltage range in reference to UN (Ambient conditions) | 0.8 ... 1.2 |
| Power dissipation for nominal condition (Ambient conditions) | 0.34 W |
| Voltage drop at max. limiting continuous current (Input data) | ≤ 2 V (URest) |