Service time: Monday to Friday 9:00-18:00
PLC-RSC-120UC/21HC/EX - PLC-RSC-120UC/21HC/EX 2909520 PHOENIX CONTACT Relay Module
In Stock Hot Product

PLC-RSC-120UC/21HC/EX

PLC-RSC-120UC/21HC/EX 2909520 PHOENIX CONTACT Relay Module

$0.00USD
4901 in stock
Key Specifications
GTIN:4055626363486
Note:Made to Order (non-returnable)
Orderkey:2909520
(General):2x 0.5 mm² ... 1.5 mm² ()
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626363486
NoteMade to Order (non-returnable)
Orderkey2909520
(General)2x 0.5 mm² ... 1.5 mm² ()
(Coil side)6 A (at 250 V, AC15)
Catalog pagePage 459 (C-5-2017)
Depth (Note)94 mm
Packing unit10 pc
Width (Note)14 mm
(Dimensions)-40 °C ... 60 °C (ATEX / IECEx)
Height (Note)80 mm
(Contact side)IP20 (Relay base)
Country of originDE (Germany)
ATEX (Contact side) II 3G Ex ec nC IIC T4 Gc
Custom tariff number85364900
IECEx (Contact side)Ex ec nC IIC T4 Gc
(Ambient conditions)110 V DC
Minimum order quantity10 pc
Screw thread (General)M3
UL, USA (Contact side)Class I, Zone 2, AEx nA nC IIC T6
Contact type (Coil side)1 PDT
Connection name (General)Coil side
UL, Canada (Contact side)Class I, Zone 2, Ex nA nC IIC Gc T6 X
Stripping length (General)8 mm
Connection method (General)Screw connection
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Coil side)AgNi
(Connection data input side)2x 0.5 mm² ... 1.5 mm² ()
Operating mode (Contact side)100% operating factor
UL, USA/Canada (Contact side)Class I, Div. 2, Groups A, B, C, D
(Connection data output side)EN 60079-0, -7, -15
Switching capacity (Coil side)2 A (at 24 V, DC13)
Net weight (SAP) (Contact side)70.63 g
IECEx certificate (Contact side)IECEx IBE 16.0029X
Mounting position (Contact side)any
ATEX (Connection data output side) II 3G Ex ec nC IIC T4 Gc
Maximum inrush current (Coil side)30 A (300 ms)
Min. switching current (Coil side)10 mA (at 12 V)
Type of switch contact (Coil side)Single contact
Degree of protection (Contact side)RT II (Relay)
IECEx (Connection data output side)Ex ec nC IIC T4 Gc
Assembly instructions (Contact side)In rows with zero spacing
Weight per Piece (excluding packing)70.630 g
Conductor cross section AWG (General)26 ... 14
Maximum switching voltage (Coil side)250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage (Coil side)12 V (at 10 mA)
UL, USA (Connection data output side)Class I, Zone 2, AEx nA nC IIC T6
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Mechanical service life (Contact side)3x 107cycles
Conductor cross section solid (General)0.14 mm² ... 2.5 mm²
Limiting continuous current (Coil side)10 A
Protective circuit (Ambient conditions)Bridge rectifier Bridge rectifier
Insulation (Connection data output side)Safe isolation, reinforced insulation
UL, Canada (Connection data output side)Class I, Zone 2, Ex nA nC IIC Gc T6 X
Conformance (Connection data output side)CE-compliant
Designation (Connection data output side)Standards/regulations
Screw thread (Connection data input side)M3
Typical release time (Ambient conditions)10 ms
Conductor cross section flexible (General)0.14 mm² ... 2.5 mm²
Typical response time (Ambient conditions)7 ms
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C (UL)
Connection name (Connection data input side)Contact side
UL, USA/Canada (Connection data output side)Class I, Div. 2, Groups A, B, C, D
Nominal input voltage UN (Ambient conditions)120 V AC
Stripping length (Connection data input side)8 mm
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Connection method (Connection data input side)Screw connection
EU-type examination certificate (Contact side)IBExU16ATEXB015 X
Operating voltage display (Ambient conditions)Yellow LED
Typical input current at UN (Ambient conditions)4.5 mA
Degree of pollution (Connection data output side)2
Interrupting rating (ohmic load) max. (Coil side)240 W (at 24 V DC)
Rated surge voltage (Connection data output side)6 kV
Overvoltage category (Connection data output side)III
Standards/regulations (Connection data output side)IEC 60664
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Rated insulation voltage (Connection data output side)250 V AC
Test voltage relay winding/relay contact (Contact side)4 kV AC (50 Hz, 1 min.)
Conductor cross section AWG (Connection data input side)26 ... 14
Interrupting rating (ohmic load) max. bridged (Coil side)144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Conductor cross section solid (Connection data input side)0.14 mm² ... 2.5 mm²
Power dissipation for nominal condition (Ambient conditions)0.54 W
Conductor cross section flexible (Connection data input side)0.14 mm² ... 2.5 mm²
Flammability rating according to UL 94 (Connection data output side)V0

Product Description

PLC-INTERFACE, consisting of a 14 mm rail-mounted base terminal block with screw connection and plug-in relay with 10 A power contact, 1 switched contact, input voltage 120 V AC/110 V DC. Approved acc
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top