Service time: Monday to Friday 9:00-18:00
PLC-RPT-72UC/21-21/RW - PLC-RPT- 72UC/21-21/RW 2900347 PHOENIX CONTACT Relay Module
In Stock Hot Product

PLC-RPT-72UC/21-21/RW

PLC-RPT- 72UC/21-21/RW 2900347 PHOENIX CONTACT Relay Module

$0.00USD
4553 in stock
Key Specifications
:Surge protection; Freewheeling diode
EMC:B
Color:gray (RAL 7042)
Depth:94 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Surge protection; Freewheeling diode
EMCB
Colorgray (RAL 7042)
Depth94 mm
Width14 mm
Height80 mm
HumidityA
EnclosureRequired protection according to the Rules shall be provided upon installation on board
VibrationB/C
InsulationBasic insulation
ApplicationRailway applications
CertificateCE-compliant
TemperatureD
Product typeRelay Module
Assembly notein rows with zero spacing
Mounting typeDIN rail mounting
IdentificationISA-S71.04. G3 Harsh Group
Operating mode100% operating factor
Product familyPLC-INTERFACE
Article revision07
Contact materialAgNi
Drive (polarity)polarized
Pollution degree2
Stripping length10 mm
Connection methodPush-in connection
Mounting positionany
Drive and functionmonostable
Protective circuitBridge rectifier
Switching capacity2 A (at 24 V, DC13)
Input voltage range50.4 V DC ... 90 V DC
Rated surge voltage6 kV
Overvoltage categoryIII
Typical release time11 ms
Installation locationAttached to the vehicle body
Low Voltage DirectiveConformance with Low Voltage Directive
Standards/regulationsIEC 60947-5-1
Typical response time5 ms
Contact switching type2 changeover contacts
Maximum inrush current15 A (300 ms)
Min. switching current10 mA (5 V)
Type of switch contactSingle contact
Mechanical service lifeapprox. 3x 107cycles
Nominal input voltage UN72 V DC
Rated insulation voltage250 V AC
Maximum switching voltage250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum switching voltage5 V (10 mA)
Operating voltage displayYellow LED
Conductor cross section AWG26 ... 14
Limiting continuous current6 A
Typical input current at UN6 mA
Date of last data management08.07.2024
Degree of protection (Relay)RT III (Relay)
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Electromagnetic compatibilityConformance with EMC directive
Test voltage (Winding/contact)5 kVrms(50 Hz, 1 min., winding/contact)
Ambient temperature (operation)-40 °C ... 70 °C (Temperature class TX)
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Degree of protection (Relay base)IP20 (Relay base)
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Flammability rating according to UL 94V0 (Housing)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum power dissipation for nominal condition0.43 W
Nominal voltage (plugged-in electromechanical relay)48 V DC
Test voltage (Changeover contact/changeover contact)2.5 kVrms(50 Hz, 1 min., changeover contact/changeover contact)

Product Description

PLC-INTERFACE for railway applications, consisting of base terminal block with push-in connection and plug-in miniature relay with power contact, range: 0.7 x UN to 1.25 x UN, TX temperature class: -4
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top