Service time: Monday to Friday 9:00-18:00
PLC-RPT-60DC/21-21 - PLC-RPT- 60DC/21-21 2900334 PHOENIX CONTACT PLC-INTERFACE, consisting of PLC-BPT.../21-21 basic terminal blo..
In Stock Hot Product

PLC-RPT-60DC/21-21

PLC-RPT- 60DC/21-21 2900334 PHOENIX CONTACT PLC-INTERFACE, consisting of PLC-BPT.../21-21 basic terminal blo..

$0.00USD
3345 in stock
Key Specifications
:Free-wheeling diode Damping diode
Depth:94 mm
Width:14 mm
Height:80 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Free-wheeling diode Damping diode
Depth94 mm
Width14 mm
Height80 mm
DesignationStandards/regulations
Contact type2 PDT
Operating mode100% operating factor
Connection nameCoil side
Contact materialAgNi
Pollution degree2
Stripping length8 mm
Connection methodPush-in connection
Mounting positionany
Protective circuitProtection against polarity reversal Polarity protection diode
Degree of protectionRT III (Relay)
Overvoltage categoryIII
Typical release time10 ms
Assembly instructionsIn rows with zero spacing
Standards/regulationsIEC 60664
Typical response time8 ms
Maximum inrush current15 A (300 ms)
Min. switching current10 mA (At 5 V)
Mechanical service life3 x 107cycles
Nominal input voltage UN60 V DC
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage5 V AC/DC (at 10 mA)
Operating voltage displayYellow LED
Conductor cross section AWG26 ... 14
Limiting continuous current6 A
Typical input current at UN10 mA
Conductor cross section solid0.14 mm² ... 2.5 mm²
Rated surge voltage/insulation6 kV (safe isolation: control side / contact side)
Ambient temperature (operation)-40 °C ... 60 °C
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Flammability rating according to UL 94V0
Ambient temperature (storage/transport)-40 °C ... 85 °C
Power dissipation for nominal condition0.6 W
Switching capacity in acc. with DIN VDE 0660/IEC 609472 A (at 24 V, DC13)

Product Description

PLC-INTERFACE, consists of a PLC-BPT.../21-21 base terminal block with push-in connection and plug-in miniature relay with power contact, for installation on symmetrical rail NS 35/7.5, 2 inverter con
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top