Service time: Monday to Friday 9:00-18:00
PLC-RPT- 48DC/21HC/MS - PLC-RPT- 48DC/21HC/MS 2910532 PHOENIX CONTACT Relay Module
In Stock Hot Product

PLC-RPT- 48DC/21HC/MS

PLC-RPT- 48DC/21HC/MS 2910532 PHOENIX CONTACT Relay Module

$0.00USD
4857 in stock
Key Specifications
GTIN:4055626486833
Note:Made to Order (non-returnable)
Orderkey:2910532
(General):cUL 508 Recognized
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626486833
NoteMade to Order (non-returnable)
Orderkey2910532
(General)cUL 508 Recognized
(Coil side)1.5 A (230 V, AC15)
Depth (Note)104 mm
Packing unit10 pc
Width (Note)14 mm
Height (Note)80 mm
(Contact side)2x 0.5 mm² ... 1 mm² ()
Country of originDE (Germany)
UL, USA (General)UL 508
Custom tariff number85364190
Insulation (General)Safe isolation, reinforced insulation
Designation (General)Standards/regulations
Contact type (Coil side)1 PDT
UL, USA/Canada (General)cUL 508
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Coil side)AgNi
(Connection data input side)2x 0.5 mm² ... 1 mm² ()
Degree of pollution (General)2
Rated surge voltage (General)6 kV
(Connection data output side)cUL 508 Recognized
Connection name (Contact side)Coil side
Overvoltage category (General)III
Switching capacity (Coil side)1 A (24 V, DC13)
Standards/regulations (General)EN 50178
Stripping length (Contact side)8 mm
Connection method (Contact side)Push-in connection
Coil voltage (Ambient conditions)24 V DC
Maximum inrush current (Coil side)24 A (20 ms)
Min. switching current (Coil side)10 mA (at 12 V)
Rated insulation voltage (General)250 V AC
Type of switch contact (Coil side)Single contact
Weight per Piece (excluding packing)64.000 g
Maximum switching voltage (Coil side)250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage (Coil side)12 V (10 mA)
UL, USA (Connection data output side)UL 508
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Limiting continuous current (Coil side)10 A
Protective circuit (Ambient conditions)Bridge rectifier Bridge rectifier
Typical release time (Ambient conditions)10 ms
Conductor cross section AWG (Contact side)26 ... 14
Typical response time (Ambient conditions)6 ms
Ambient temperature (operation) (Dimensions)-40 °C ... 60 °C
Conductor cross section solid (Contact side)0.14 mm² ... 2.5 mm²
Connection name (Connection data input side)Contact side
Operating mode (Connection data output side)100% operating factor
UL, USA/Canada (Connection data output side)cUL 508
Nominal input voltage UN (Ambient conditions)48 V DC
Stripping length (Connection data input side)8 mm
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Connection method (Connection data input side)Push-in connection
Operating voltage display (Ambient conditions)Yellow LED
Conductor cross section flexible (Contact side)0.14 mm² ... 2.5 mm²
Mounting position (Connection data output side)any
Flammability rating according to UL 94 (General)V0
Typical input current at UN (Ambient conditions)19 mA
Interrupting rating (ohmic load) max. (Coil side)264 W (24 V DC)
Degree of protection (Connection data output side)RT II (Relay)
Assembly instructions (Connection data output side)In rows with zero spacing
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Mechanical service life (Connection data output side)5x 106cycles
Conductor cross section AWG (Connection data input side)26 ... 14
Conductor cross section solid (Connection data input side)0.14 mm² ... 2.5 mm²
Conductor cross section flexible (Connection data input side)0.14 mm² ... 2.5 mm²
Test voltage relay winding/relay contact (Connection data output side)4 kVrms(50 Hz, 1 min.)

Product Description

PLC-INTERFACE, composed of socket relay and relay with plug-in power contact with manual activation, integrated status LED and free circulation diode, Push-in connection, 1 switch, Rectifier bridge, I
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

14 mm PLC basic terminal block without relay, for mounting on DIN rail NS 35/7,5, Push-in connection, 1 PDT, Input voltage 48 V DC

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide