| Parameter | Value |
|---|---|
| 900000 Cycles (AC1; 250 V / 3 A; 1 NO) | |
| EMC | B |
| B10d | 600000 Cycles (AC1; 250 V / 6 A; 1 NO) |
| Color | gray (RAL 7042) |
| Depth | 104 mm |
| Width | 14 mm |
| Height | 80 mm |
| Altitude | ≤ 2000 m |
| Humidity | A |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Vibration | B/C |
| Insulation | Safe isolation, reinforced insulation |
| Application | Forcibly guided contacts |
| Certificate | CE-compliant |
| Temperature | D |
| Product type | Relay Module |
| Assembly note | in rows with zero spacing |
| Mounting type | DIN rail mounting |
| Identification | UL 508 |
| Operating mode | 100% operating factor |
| Product family | PLC-INTERFACE |
| Article revision | 03 |
| Contact material | AgNi |
| Drive (polarity) | polarized |
| Pollution degree | 2 |
| Stripping length | 10 mm |
| Connection method | Push-in connection |
| Mounting position | any |
| Drive and function | monostable |
| Protective circuit | Freewheeling diode |
| Switching capacity | 3 A (24 V, DC13) |
| Input voltage range | 20.2 V DC ... 32.4 V DC (20 °C) |
| Rated surge voltage | 6 kV |
| Overvoltage category | III |
| Typical release time | 10 ms |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Standards/regulations | IEC 60947-5-1 |
| Typical response time | 10 ms |
| Contact switching type | 2 changeover contacts, forcibly actuated |
| Maximum inrush current | 6 A |
| Min. switching current | 10 mA (5 V) |
| Type of switch contact | Single contact |
| Mechanical service life | approx. 107cycles |
| Switching capacity min. | 150 mW |
| Nominal input voltage UN | 24 V DC |
| Rated insulation voltage | 250 V AC |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (10 mA) |
| Operating voltage display | Yellow LED |
| Conductor cross section AWG | 26 ... 14 |
| Limiting continuous current | 6 A |
| Typical input current at UN | 30 mA |
| Date of last data management | 08.07.2024 |
| Degree of protection (Relay) | RT II (Relay) |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Electromagnetic compatibility | Conformance with EMC directive |
| Test voltage (Winding/contact) | 4 kVrms(50 Hz, 1 min., winding/contact) |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Degree of protection (Relay base) | IP20 (Relay base) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC) |
| Input voltage range in reference to UN | see diagram |
| Ambient temperature (storage/transport) | -20 °C ... 85 °C |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Maximum power dissipation for nominal condition | 0.72 W |
| Force-guided contacts in accordance with EN 61810-3 | Type B |
| Nominal voltage (plugged-in electromechanical relay) | 24 V DC |
| Test voltage (Changeover contact/changeover contact) | 2.5 kVrms(50 Hz, 1 min., changeover contact/changeover contact) |
Technical specifications and performance data