Service time: Monday to Friday 9:00-18:00
PLC-RPT-24DC/21HC - PLC-RPT- 24DC/21HC 2900291 PHOENIX CONTACT Relay Module
In Stock Hot Product

PLC-RPT-24DC/21HC

PLC-RPT- 24DC/21HC 2900291 PHOENIX CONTACT Relay Module

$0.00USD
4292 in stock
Key Specifications
():IP20 (Relay base)
GTIN:4046356509268
Orderkey:2900291
(General):EN 50178
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
()IP20 (Relay base)
GTIN4046356509268
Orderkey2900291
(General)EN 50178
(Coil side)6 A (at 250 V, AC15)
Catalog pagePage 387 (C-5-2017)
Depth (Note)94 mm
Packing unit10 pc
Width (Note)14 mm
Height (Note)80 mm
(Contact side)2x 0.5 mm² ... 1 mm² ()
Country of originDE (Germany)
Operating mode ()100% operating factor
Net weight (SAP) ()60.6 g
Custom tariff number85364900
Insulation (General)Safe isolation, reinforced insulation
Mounting position ()any
Designation (General)Standards/regulations
Protective circuit ()Reverse polarity protection Polarity protection diode
Degree of protection ()RT II (Relay)
Typical release time ()10 ms
Assembly instructions ()In rows with zero spacing
Contact type (Coil side)1 PDT
Typical response time ()8 ms
Mechanical service life ()3x 107cycles
Nominal input voltage UN ()24 V DC
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Contact material (Coil side)AgNi
Operating voltage display ()Yellow LED
Degree of pollution (General)2
Rated surge voltage (General)6 kV
Connection name (Contact side)Contact side
Overvoltage category (General)III
Switching capacity (Coil side)2 A (at 24 V, DC13)
Typical input current at UN ()18 mA
Standards/regulations (General)IEC 60664
Stripping length (Contact side)8 mm
Connection method (Contact side)Push-in connection
Maximum inrush current (Coil side)30 A (300 ms)
Min. switching current (Coil side)10 mA (at 12 V)
Type of switch contact (Coil side)Single contact
Weight per Piece (excluding packing)60.600 g
Maximum switching voltage (Coil side)250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage (Coil side)12 V (at 10 mA)
Ambient temperature (operation) (Note)-40 °C ... 60 °C
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Limiting continuous current (Coil side)10 A
Conductor cross section AWG (Contact side)26 ... 14
Connection in acc. with standard (General)CUL
Power dissipation for nominal condition ()0.43 W
Conductor cross section solid (Contact side)0.14 mm² ... 2.5 mm²
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Ambient temperature (storage/transport) (Note)-40 °C ... 85 °C
Conductor cross section flexible (Contact side)0.14 mm² ... 2.5 mm²
Flammability rating according to UL 94 (General)V0
Interrupting rating (ohmic load) max. (Coil side)240 W (at 24 V DC)
Interrupting rating (ohmic load) max. bridged (Coil side)144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.)

Product Description

PLC-INTERFACE for high constant currents, consisting of PLC-BPT.../21 HC base terminal block with push-in connection and plug-in miniature relay, for mounting on NS 35/7.5 rail, constant current limit
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

14 mm PLC basic terminal block for high continuous currents with push-in connection, without relay or solid-state relay, for mounting on DIN rail NS 35/7,5, 1 PDT, input voltage 24 V DC

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top