| Parameter | Value |
|---|---|
| () | IP20 (Relay base) |
| GTIN | 4046356506991 |
| Note () | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500.... |
| Orderkey | 2900299 |
| (General) | IEC 60255/DIN VDE 0435 (in relevant parts) |
| (Coil side) | 3 A (at 230 V, AC15) |
| Catalog page | Page 372 (C-5-2017) |
| Depth (Note) | 94 mm |
| Packing unit | 10 pc |
| Width (Note) | 6.2 mm |
| Height (Note) | 80 mm |
| (Contact side) | 2x 0.5 mm² ... 1 mm² () |
| Country of origin | DE (Germany) |
| Operating mode () | 100% operating factor |
| Net weight (SAP) () | 32.466 g |
| Custom tariff number | 85364190 |
| Mounting position () | any |
| Designation (General) | Standards/regulations |
| Protective circuit () | Reverse polarity protection Polarity protection diode |
| Degree of protection () | RT III (Relay) |
| Typical release time () | 8 ms |
| Assembly instructions () | In rows with zero spacing |
| Contact type (Coil side) | 1 PDT |
| Typical response time () | 5 ms |
| Mechanical service life () | 2x 107cycles |
| Note (Key Commercial Data) | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500.... |
| Nominal input voltage UN () | 24 V DC |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Contact material (Coil side) | AgSnO |
| Operating voltage display () | Yellow LED |
| Degree of pollution (General) | 3 |
| Connection name (Contact side) | Contact side |
| Overvoltage category (General) | III |
| Switching capacity (Coil side) | 2 A (at 24 V, DC13) |
| Typical input current at UN () | 9 mA |
| Standards/regulations (General) | IEC 60664 |
| Stripping length (Contact side) | 8 mm |
| Connection method (Contact side) | Push-in connection |
| Maximum inrush current (Coil side) | 10 A (4 s) |
| Min. switching current (Coil side) | 10 mA (at 12 V) |
| Type of switch contact (Coil side) | Single contact |
| Weight per Piece (excluding packing) | 32.470 g |
| Maximum switching voltage (Coil side) | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Minimum switching voltage (Coil side) | 5 V (at 100 mA) |
| Ambient temperature (operation) (Note) | -40 °C ... 60 °C |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Limiting continuous current (Coil side) | 6 A |
| Conductor cross section AWG (Contact side) | 26 ... 14 |
| Connection in acc. with standard (General) | CUL |
| Power dissipation for nominal condition () | 0.22 W |
| Test voltage relay winding/relay contact () | 4 kV AC (50 Hz, 1 min.) |
| Conductor cross section solid (Contact side) | 0.14 mm² ... 2.5 mm² |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Ambient temperature (storage/transport) (Note) | -40 °C ... 85 °C |
| Conductor cross section flexible (Contact side) | 0.14 mm² ... 2.5 mm² |
| Flammability rating according to UL 94 (General) | V0 |
| Interrupting rating (ohmic load) max. (Coil side) | 140 W (at 24 V DC) |
Technical specifications and performance data